Records from 2016 to 2026. Most recent: inspection, 17 March 2026.
Inspection history · 39
17 March 2026
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8327398
11 July 2025
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8182403
10 June 2025
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8156508
6 June 2025
PSC B · CCSSC Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8153036
19 May 2025
Administrative Inspection · CCSSC Examination · PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8139078
4 January 2025
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8056982
30 October 2024
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8026589
6 September 2024
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7996832
7 April 2024
CCSSC Examination · PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7890822
5 April 2024
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7890478
4 October 2023
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7799682
28 March 2023
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7658167
19 January 2023
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7623966
26 September 2022
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7566105
10 August 2022
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7529778
3 May 2022
Administrative Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7443009
22 March 2022
PSC B · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7415914
7 December 2021
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7363743
18 August 2021
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7289328
12 August 2021
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7283765
17 March 2021
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7157996
9 February 2021
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7133727
27 January 2021
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7131851
27 May 2020
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6962039
19 September 2019
Ballast Water Examination · PII Safety Exam · CCSSC Examination · ISPS III Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6809893
20 March 2019
CCSSC Examination · Ballast Water Examination · PII Safety Exam · ISPS III Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6645717
11 October 2018
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6559153
24 September 2018
ISPS II Exam · Ballast Water Examination · CCSSC Examination · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6547031
28 March 2018
CCSSC Examination · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6379668
2 October 2017
CCSSC Examination · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6279325
29 March 2017
MTSA/ISPS Verification · CCSSC Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6113652
23 February 2017
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6093197
16 January 2017
In-Service Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6071449
17 October 2016
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6024061
13 October 2016
Deficiency Check · In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6021721
28 September 2016
ISPS II Exam · In-Service Inspection · CCSSC Examination · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6011511
10 September 2016
Security Plan Review - ASP
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5996969
1 April 2016
ISPS II Exam · CCSSC Examination · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5844979
19 February 2016
Security Plan Review - VSP
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5818481
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 6 June 2025
Resolved
In a ship in which oil fuel is used, the arrangements for the storage, distribution and utilization of the oil fuel shall be such as to ensure the safety of the ship and persons on board. PSCOs observed a leak coming from the injection pump at a fuel line connection on the starboard side diesel generator.
CCSSC (20) Reg. 3.20.2
Code 17bc
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 June 2025
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 6 June 2025
Resolved
The emergency fire pump shall be capable of producing at least a jet of water of not less than 6 m in any condition and state of trim of the vessel. During the operational test of the emergency fire pump a gauge line pipe ruptured rendering the system non-operational.
CCSSC (20) Reg. 3.3.7.2
Code 17bc
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 June 2025
Resolution: Ruptured pipe was replaced and a satisfactory test was conducted prior to the completion of the exam.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 June 2025
Resolved
In a ship in which oil fuel is used, the arrangements for the storage, distribution and utilization of the oil fuel shall be such as to ensure the safety of the ship and persons on board. PSCOs observed fuel oil leaks coming from the port side main diesel engine injector fitting and the starboard side diesel generator injector pump.
CCSSC (20) Reg. 3.20.2
Code 16bc
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 June 2025
Resolved 7 June 2025
Resolution: Class Survey Report attesting to rectification of def.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 June 2025
Resolved
The arrangements for storage, distribution and utilization of oil used in pressure lubricating systems shall be such as to ensure the safety of the ship and persons on board. PSCOs observed lube oil leaks coming from the port side main diesel engin governor, pressure switch located above the port side main diesel engine turbo and port side diesel generator accessory drive.
CCSSC (20) Reg. 3.20.3
Code 16bc
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 June 2025
Resolved 7 June 2025
Resolution: Class Survey Report attesting to rectification of def.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 6 June 2025
Resolved
All machinery and electrical installations, mechanical and electrical equipment and appliances, boilers and other pressure vessels, associated piping systems, fittings and electrical cables and wiring shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to person on board, due regard being paid to moving parts, hot surfaces and other hazards. PSCOs observed an exhaust leak coming from the starboard side diesel generator upon start up.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 June 2025
Resolved 7 June 2025
Resolution: Class Survey Report attesting to rectification of def.
05 - Radio Communications › N/A - No Subsystem › Performance standards for radio equipment
Issued 6 June 2025
Resolved
All equipment to which this chapter applies shall be of a type approved by the Administration. Such equipment shall conform to appropriate performance standards not inferior to those adopted by the Organization. PSCO observed that the NAVTEX display device did not meet the requirements of MSC.148(77) 5.1. The display device was unable to display a minimum of 32 characters per line.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 June 2025
Resolved 27 June 2025
Resolution: New NAVTEX display installed.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Construction (including exempt.)
Issued 19 May 2025
Resolved
A minimum of two inspections of the outside of the ship's bottom shall be carried out during any five year period... in all cases the interval between any two such inspections shall not exceed thirty-six months. PSCO's observed the last documented inspection of the outside of ship's bottom was on 20 MAR 2022, which exceeds the thirty-six month requirement.
CCSSC (97)Ch. 1 / Reg. 1.10.1.5
Code 30ac
Action required: 30 - Ship detained
Due 20 June 2025
Resolved 20 May 2025
Resolution: Flag Administration provided dispensation letter and approved short-term extension of the vessel's CCSSC for the vessel to complete their in-water survey by June 24, 2025 with requirements confirmed by the vessel's master.
12 - Dangerous Goods › N/A - No Subsystem › Fire protection cargo deck area
Issued 22 March 2022
Resolved
Ships intended for the carriage of dangerous goods shall comply with the special requirements as specified in Chapter II-2 of the 1974 Solas Convention. Arrangements shall be made to ensure immediate availability of a supply of water from the fire main at the required pressure either by permanent pressurization or by suitability placed remote arraignments for the fire pumps. Emergency fire pump does not have means for remote start.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 April 2022
Resolved 3 May 2022
Resolution: Received Flag Report of SAT install and op. of e-fire pump remote arrangements
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 12 August 2021
Resolved
Rescue boats shall be stowed in a state of continuous readiness for launching in not more than 5 min...during test of the rescue boat davit, limit switch failed causing the line to part and the boat to fall. CCSS Code 4.9.8.1. 17BC
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 August 2021
Resolution: PSCO's attended for def check.
10 - Safety of Navigation › N/A - No Subsystem › Variable pitch indicator
Issued 9 February 2021
Resolved
The position of the rudder, if powered, shall be indicated at the Navigation Bridge... PSCO's could not verify true position of the rudder. Bridge indicated 30° port reading, local reading was 35° port. CCSSC CH.2 Reg. 2.33.8
50AC
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 March 2021
Resolved 9 March 2021
Resolution: Repaired rudder angle indicator.
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 19 September 2019
Resolved
The Rings, Lines, and Letters shall be painted in white or yellow on a dark background...shall also be permanently marked on the sides of the ship. The letters on the load lines are painted but not permanently marked. ICLL 66/88 Annex I, Chap. 1/Reg 8
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 October 2019
Resolved 27 September 2019
Resolution: Vessel sent in Flag attestation letter. Load lines have been permanently marked. See attached in documents.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 19 September 2019
Resolved
Each survival craft and rescue boat shall be marked in accordance with the requirements of the LSA code. Each rescue boat must be marked with the requirements of paragraph 4.4.9...The name and port of registry of the ship shall be marked on each side of the boat. The rescue boat did not have the name or port marked on the port side. CCSSC Ch. 4/4.5 (LSA Code 5.1.3.4)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 October 2019
Resolved 27 September 2019
Resolution: Vessel sent in Flag attestation letter and photos showing the rescue boat is now properly marked. See attached documents.
01 - Certificates & Documentation › 013 - Documents › Garbage record book
Issued 24 September 2018
Resolved
2120 - Garbage - Garbage record books are to be maintained by vessels over 400 GT. Vessel has been incorrectly maintaining garbage record book (GRB) by combining all categories of waste and notating as one amount discharged additionally vessel has been notating the amount discharged to a reception facility as amount incinerated. - CCSSC (2015) Ch. 7.5.5
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 October 2018
Resolved 10 October 2018
Resolution: Vessel provided copy of Garbage Record Book filled out correctly. Flag Attestation Letter was also forwarded that attested to the training of the chief engineer and correction of garbage record book.
08 - Alarms › N/A - No Subsystem › Steering gear alarm
Issued 24 September 2018
Resolved
103 - Steering Gear Alarm - In the event of failure of electrical power to main steering an alarm shall be given on the navigation bridge. When securing power by tripping breaker to steering pump no alarm was sounded on bridge. - CCSSC (2015) Ch. 2.33.7
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 24 September 2018
Resolved 25 September 2018
Resolution: Flag attestation received, reviewed and accepted by PSCO.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 September 2018
Resolved
0650 - Lifebouys - At leaste two of the lifebouys provided with self-igniting lights shall also be provided with self-activating smoke signals. Two of the required life bouys were not attached to self igniting lights and self activating smoke. Lines connecting the bouys to the smoke where either not spliced or the splicing came loose. - CCSSC (2015) Ch. 4.12.3
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 24 September 2018
Resolved 24 September 2018
Resolution: Vessel spliced the line connecting the bouy to the smoke signal.
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 16 January 2017
Resolved
1410-Propulsion Main Engine-The condition of the ship shall be maintained in all aspects to ensure that it remain fit to proceed to sea without danger to the ship, persons on board or the environment. Port main engine is not operational due to cooling system leak. CCSSC (2015) 1.11.1; 17bc
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 January 2017
Resolution: O/O elected to completely overhaul the engine due to engine hours.
Fire Fighting › Emergency Fire Pumps › Arrangement
Issued 17 October 2016
Resolved
03 - 0740 - CCSSC CHAP 3.3.10.1 AN EMERGENCY FIRE PUMP SHALL BE POSITIONED OUTSIDE THE ENGINE ROOM AND PERMANENTLY CONNECTED TO THE FIREMAINS. THE USE OF PORTABLE FIRE PUMPS SHALL BE AVOIDED. SHIP DOES NOT HAVE FIXED EMERGENCY FIRE PUMP.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 February 2017
Resolved 21 February 2017
Resolution: Flag survey report submitted attesting to installation of fixed emergency fire pump.
Engineering › Reduction Gearing/Clutches › Gear
Issued 14 October 2016
Resolved
Means shall be provided whereby normal operations of propulsion machinery can be sustained or restored. Port main diesel engine reduction gear is inoperative. CCSSC CH.2 Reg. 2.30.2.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 October 2016
Resolution: Vessel provided Flag attestation report informing that the port main diesel engine reduction gear was satisfactorily repaired and tested. CG marine inspectors verified operation of forward and stern propulsion.
Lifesaving › Launching Appliances › Padeye
Issued 29 September 2016
Resolved
0615 - Rescue boat - Fittings used in connection with launching equipment shall be designed with a factor of safety. Rescue boat forward pad eye not secured to deck. CCSSC Ch 4/Reg 4.3.1 LSA Code Ch VI/6.1.1.6
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 October 2016
Resolution: Backing plate installed at lifting point. Attestation provided.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 29 September 2016
Resolved
1730 - Oily-water separating equipment - Oil filtering equipment shall be of a design approved by the administration. Oil content meter was replaced by company without verification of proper operation by flag administration. MARPOL (11 cons) ANNEX I/Reg 14.6
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 October 2016
Resolution: Flag attestation to installation provided.
Lifesaving › Inflatable Liferafts › Container Marking
Issued 29 September 2016
Resolved
0620 - Inflatable liferafts - Inflatable liferaft containers shall be marked. The vessel's liferafts (02) are missing service data labels. CCSSC Ch 4/Reg 4.3.1 LSA Code Ch IV/4.2.6.3
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 October 2016
Resolution: Sticker provided to liferaft.
Engineering › Reduction Gearing/Clutches › Seal
Issued 29 September 2016
Resolved
1410 - Propulsion main engine - Means shall be provided whereby normal operations of propulsion machinery can be sustained or restored. Port main diesel engine reduction gear housing gasket failed, resulting in excessive oil leak. CCSSC Ch 2/Reg 2.30.2.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 October 2016
Resolution: Flag attestation provided.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 29 September 2016
Resolved
0950 - Electric equipment in general - Electrical installations shall be such that the safety of personnel and ship from electrical hazards will be assured. Wiring junction box in paint locker wasted. CCSSC Ch 2/Reg 2.26.1.3
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 October 2016
Resolved 3 October 2016
Resolution: CG Inspector approves.