Records from 2016 to 2024. Most recent: inspection, 12 November 2024.
Documentation record
Registered dimensions (L × B × D)133.2 ft × 28.0 ft × 12.1 ft
Registered tonnagegross 95 / net 65
ITC dimensions (L × B × D)133.2 ft × 28.0 ft × 12.1 ft
ITC tonnagegross 295 / net 88
BuilderBREAUX'S BAY CRAFT INC · LOREAUVILLE, LA, UNITED STATES · built 2006
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portFREEPORT, TX
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 20 February 2026 · expires 28 February 2027
Service, as the file records itResearch Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it95 - Regulatory (Subpart C or D), Gross Ton
295 - Convention (Subpart B), Gross Ton
65 - Regulatory (Subpart C or D), Net Ton
88 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 23
12 November 2024
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8033831
27 March 2024
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7885584
20 March 2024
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7882247
22 June 2023
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7720474
1 December 2022
Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7602997
16 May 2022
Internal Structural Exam · Annual Inspection · Deficiency Check · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7452344
27 May 2021
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7208013
8 December 2020
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7108457
19 May 2020
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6955720
12 May 2020
Administrative Inspection · Internal Structural Exam · Hull Examination · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6952236
8 August 2019
Annual Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6777014
1 May 2018
Drydock Exam · Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6403401
28 February 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6363359
31 July 2017
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6227571
15 May 2017
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6147769
12 May 2017
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6144975
12 May 2017
Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6146336
1 May 2017
Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6137301
24 April 2017
Internal Structural Exam · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6131629
18 October 2016
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6025094
3 October 2016
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6015078
23 May 2016
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5884631
10 May 2016
DAPI Audit · Hull Examination · Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5873813
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 2 December 2022
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. Vessel has sustained damage to the STBD bow, with 02 3in. X 4in. punctures approximately 8ft. above the waterline. Provide repair proposal and conduct repairs to the satisfaction of a USCG Marine Inspector.
- 46 CFR 177.100
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 2 December 2022
Resolved 2 December 2022
Resolution: Repairs were conducted to the satisfaction of the attending USCG Marine Inspector.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 27 May 2021
Resolved
A hatch exposed to the weather must be watertight. the engine room softpatches are cracked, compromising the watertight integrity of the vesse. Provide permanent or temproary repair proposal prior to departure repairs. Shall be completed to the satiisfaction of the attending CG marine inspector.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 1 June 2021
Resolved 27 May 2021
Resolution: Vessel gouged and welded cracks in soft patches and NDT'd using dye and penetrant. Provided proof of repair via video.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 19 May 2020
Resolved
At each inspection for COI the operator must be prepared to conduct tests and have the VSL ready for inspection of electrical equipment and systems.
STBD generator would not start.
STBD generator should be repaired and operate as designed.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 June 2020
Resolved 19 May 2020
Resolution: Technician fixed the generator.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 8 August 2019
Resolved
At each initial and subsequent inspection for certification, the owner or managing operator must be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment, including inspection and testing of all smoke and fire detection systems, including sensors and alarms. Vessel representative and crew were unable to prove annual testing of the fire detection system and alarm panel.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 August 2019
Resolution: Received, reviewed and accepted third party company's tech report attesting to the testing and satisfactory operation of the fire detection alarm panel.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 August 2019
Resolved
Each ungrounded system must be provided with a suitably sensitive ground detection system located at the respective switchboard that provides a continuous indication of the circuit status to ground with a provision to momentarily remove the indicating device from the reference ground. Ground detection system test function did not function as designed and Marine Inspectors were unable to verify the ground detection system's functionality.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 August 2019
Resolution: Received, reviewed and accepted video and third party electricians report attesting to the proper operation of the main switch board's active ground detection system. Vsl has a ground detection system meetig 46 CFR 183.376.
Construction/Loadline › Hull › Longitudinal Frame
Issued 24 April 2017
Resolved
4" crack in the forepeak longitudinal frame, crop and renew frame.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 1 May 2017
Resolution: cropped and renewed frame.
Fire Fighting › Fire Pumps › Pressure
Issued 24 April 2017
Resolved
Not reaching minimum requirement of 60psi (50psi) at pump.
Action required: 705 - Other - as specified
Due 24 May 2017
Resolved 12 May 2017
Resolution: Installed and tested new fire pump, all test sat.
Electrical › Electrical Distribution System (service) › Wiring
Issued 24 April 2017
Resolved
Dead end wiring in the forepeak and AFT deck. Remove/cap dead end wire and make safe.
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 1 May 2017
Resolution: Placed dead in wire in J-box.