Records in 2017. Most recent: inspection, 19 October 2017.
Operations/Management › Drills/Instruction › Not Conducted
Issued 25 January 2017
No resolution recorded
Vessel must conduct fire, abandon ship, person in the water drills, prior to getting underway, and to the satisfaction of attending CG Marine Inspector. 46CFR 131.535, 46 CFR 133.135, 46 CFR 131.530 Prior To Sail
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Engineering › Fuel Oil Service System › Piping
Issued 24 January 2017
Resolved
Marine Inspectors found several missing and loose support brackets on fuel rail for both main engines, bow thruster, and generators. Renew/replace all fuel rail brackets. In addition, remove all brackets on all prime movers to inspect fuel rail and report findings to attending USCG Marine inspectors or ABS Surveyor. 46 CFR 56.50-70(b)(1)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 January 2017
Resolution: ABS Surveyor [name withheld] accepted as Condition of Class, see email confirmation in documents.
Electrical › Electrical Distribution System (service) › Grounding Conductor
Issued 24 January 2017
Resolved
Marine Inspectors identified a "ground fault" on both main engines and centerline generator. Upon further inspection, MI's found welding cables being used as a ground and showed excessive wastage. replace with suitable material to the satisfaction of attending USCG Marine Inspector or ABS Surveyor. 46 CFR 111.60
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 January 2017
Resolution: ABS Surveyor [name withheld] accepted as Condition of Class, see email confirmation in documents.
Fire Fighting › Fire Main › Valves
Issued 24 January 2017
Resolved
Marine Inspector found a wasted butterfly valve handle on the fire main for the international shore connection. Replace to the satisfaction of the attending Marine Inspector or ABS Surveyor. 46 CFR 132.110
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 January 2017
Resolution: ABS Surveyor [name withheld] accepted as Condition of Class, see email confirmation in documents.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 24 January 2017
Resolved
Marine Inspectors found several fire doors throughout the vessel that would not close completely (self closing). Adjust to the satisfaction of attending USCG Marine inspector or ABS Surveyor. 46 CFR 127.220, 46 CFR 72.05-10
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 January 2017
Resolution: ABS Surveyor [name withheld] accepted as Condition of Class, see email confirmation in documents.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 24 January 2017
Resolved
Marine Inspectors saw no visible egress sinage or IMO symbols in the tank farm. Place appropriate symbols ot the satisfaction of the attending USCG Marine Inspector or ABS Surveyor. 46 CFR 127.240(b)
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 January 2017
Resolution: ABS Surveyor [name withheld] accepted as Condition of Class, see email confirmation in documents.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 24 January 2017
Resolved
Marine Inspectors found several watertight doors and fire doors with "tie backs". Remove immediatly to the satisfaction of the attending USCG MI. 46 CFR 42.15
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 January 2017
Resolution: ABS Surveyor [name withheld] accepted as Condition of Class, see email confirmation in documents.
Fire Fighting › Ventilation Systems › Ducts
Issued 24 January 2017
Resolved
Marine Inspector found missing/melted dryer vent on laundry dryer on 02 deck. Repair/replace prior to use. verify all laundry dryer vents are properly installed to the satisfaction of attending USCG Marine Inspector or ABS Surveyor. 46 CFR 126.100
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 January 2017
Resolution: ABS Surveyor [name withheld] accepted as Condition of Class, see email confirmation in documents.
Construction/Loadline › Penetrations › Gasket
Issued 24 January 2017
Resolved
Marine Inspectors identified a "softgasket" on the watertight door from engine room to the tank farm. Replace to the satisfaction of attending USCG Marine Inspector or ABS Surveyor. 46 CFR 170.270 (b)
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 January 2017
Resolution: USCG Marine Inspector verified soft gasket replaced with satisfactory hard gasket.
Lifesaving › Lifebuoys › Serviceable
Issued 24 January 2017
Resolved
Marine Inspectors found both bridge ring life bouys with wated plugs. In addition, several ring bouys were found with wasted line, insufficient retro tape(name painted over). Repair/replace to the satisfaction of attending USCG Marine Inspector or ABS Surveyor. 46 CFR 133.70
Condition: Improper/Lack of Maintenance
Action required: 66 - Prior to drilling or production operations
Resolved 8 February 2017
Resolution: Ring bouys replaced
Fire Fighting › Emergency Fire Pumps › Arrangement
Issued 24 January 2017
Resolved
During testing of both main & emergency fire pumps, Marine Inspectos noted the bauge for both pumps were inoperable on the bridge. Repair to the satisfaction of attending USCG Marine Inspector or ABS Surveyor. 46 CFR 130.430
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 February 2017
Resolved 30 January 2017
Resolution: ABS Surveyor [name withheld] accepted as Condition of Class, see email confirmation in documents.
Lifesaving › Rescue Boat › Markings
Issued 24 January 2017
Resolved
Navigation light on rescue boat is not mounted correctly. Mount Correctly to the satisfaction of attending USCG Marine Inspector or ABS Surveyor. 46CFR 133.135 NAV Rules
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 7 February 2017
Resolved 30 January 2017
Resolution: ABS Surveyor [name withheld] accepted as Condition of Class, see email confirmation in documents.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 24 January 2017
Resolved
Several deck cargo piping and freshwater butterfly vavle handles wasted. In addition, several support brackets are wasted. Repair/replace to the satisfaction of attending USCG Marine Inspector or ABS Surveyor. 46 CFR 126.100
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 February 2017
Resolved 30 January 2017
Resolution: ABS Surveyor [name withheld] accepted as Condition of Class, see email confirmation in documents.
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 24 January 2017
Resolved
Guages on both air receivers are maxed out at 300 psi. MAWP is 300 psi. Relief valves are set at 250 psi, gauges are required to be at 1.2 -2.0 times the setting of the relief valve. Replace to the satisfaction of USCG Marine Inspector or ABS Surveyor. 46 CFR 54.15-5 (f)
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 7 February 2017
Resolved 30 January 2017
Resolution: ABS Surveyor [name withheld] accepted as Condition of Class, see email confirmation in documents.
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 24 January 2017
Resolved
Several holels and inability to close ventilation on paint locker, fuel supply lockers were found. Repair to the satisfaction of attending USCG Marine Inspector or ABS Surveyor. 46 CFR 132.310
Condition: Improper/Lack of Maintenance
Due 7 February 2017
Resolved 25 January 2017
Resolution: Observed satisfactory repair to ventilation and penitrations.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 24 January 2017
Resolved
Alcohol testing strips expired. Place valide ones on board. 46 CFR 4.06-15
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 January 2017
Resolved 10 February 2017
Resolution: Recieved evidence that DOT approvied alcohol testing strips had been place on board.
Electrical › Electrical Distribution System (service) › Overcurrent Device
Issued 24 January 2017
Resolved
Panels P1 and P3 (distribution panels) have breakers installed that do not match index. Ensure overcurrent protection is to the satisfaction of attending USCG Marine Inspector or ABS Surveyor. 46 CFR 129.330, 46 CFR 111.40
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 23 February 2017
Resolved 30 January 2017
Resolution: ABS Surveyor [name withheld] accepted as Condition of Class, see email confirmation in documents.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 24 January 2017
Resolved
Marine Inspector found 02 junction boxes loose and not secured on the 02 deck. Repair to the satisfaction of attending USCG Marine Inspector or ABS Surveyor.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 February 2017
Resolved 30 January 2017
Resolution: ABS Surveyor [name withheld] accepted as Condition of Class, see email confirmation in documents.
Construction/Loadline › Structures › Door
Issued 24 January 2017
Resolved
Starboard weathertight door on bridge has wastage near bottom. Repair/replace to the satisfaction of attending USCG Marine Inspector or ABS Surveyor. 46 CFR 42.12-30
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 February 2017
Resolved 30 January 2017
Resolution: ABS Surveyor [name withheld] accepted as Condition of Class, see email confirmation in documents.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 24 January 2017
Resolved
Vessel missing several eyewash containers throughout the vessel. Replace to the satisfaction of attending USCG Marine Inspector or ABS Surveyor.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 January 2017
Resolved 30 January 2017
Resolution: ABS Surveyor [name withheld] accepted as Condition of Class, see email confirmation in documents.
Deck/Cargo › Mooring/Anchoring › Standard Link (anchor chain)
Issued 24 January 2017
Resolved
Marine Inspector identified an elongated anchor link. Prove proper operation to satisfaction of attending USCG Marine Inspector or ABS Surveyor. 46 CFR 130.240 ABS Class Rules
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 23 February 2017
Resolved 30 January 2017
Resolution: ABS Surveyor [name withheld] accepted as Condition of Class, see email confirmation in documents.