STARLITE INFINITY
Passenger (Inspected) · Passenger Ship class · Built 2000s · USCG Southeast District (CGD-SE) · Other hulls named STARLITE INFINITY
STARLITE INFINITY is a 2006 passenger vessel (inspected). The Coast Guard has recorded 39 inspections since 2005, most recently in April 2026, along with 115 deficiencies, 2 operational controls, 1 with no removal date recorded and 1 casualty investigation in 2010.
Records from 2005 to 2026. Most recent: inspection, 30 April 2026.
- Built
- 2006
- Last inspected
- 30 April 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 115 recorded · 0 without a recorded resolution
- Controls
- 1 with no removal date recorded
- Casualties
- 1 investigation · 2010
Identity
1189123
WDD5754
839264
Flag
UNITED STATES
367163080, 368459360
Maury page id
psix-839264
Inspections, by type
…with no type recorded3
Years with a record
18 calendar years (2005–2026)
The 39 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)98.4 ft × 34.7 ft × 9.9 ft
Registered tonnagegross 98 / net 86
ITC dimensions (L × B × D)98.4 ft × 34.7 ft × 9.9 ft
ITC tonnagegross 782 / net 249
BuilderKEITH MARINE INC · PALATKA, FL, UNITED STATES · built 2006
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portCLEARWATER, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 7 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it782 - Convention (Subpart B), Gross Ton
98 - Regulatory (Subpart C or D), Gross Ton
249 - Convention (Subpart B), Net Ton
86 - Regulatory (Subpart C or D), Net Ton
98 - Regulatory (Subpart C or D), Gross Ton
249 - Convention (Subpart B), Net Ton
86 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDQ8146MMSI 368459360 · active · compulsorily equipped · granted 26 February 2026, expires 26 February 2036
WDD5754MMSI 367163080 · active · compulsorily equipped · granted 18 January 2017, expires 26 January 2027
WDF4053MMSI 367447420 · expired · compulsorily equipped · granted 14 April 2010, cancelled 20 June 2020 · licensed under a name not among this hull’s recorded names (not shown)
WDD5391MMSI 367157620 · cancelled · voluntarily equipped · granted 29 December 2006, cancelled 25 January 2007
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 39
30 April 2026
Administrative Inspection · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8343435
22 October 2025
Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8239668
15 September 2025
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8225172
18 September 2024
Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8004114
2 November 2023
Internal Structural Exam · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7809754
18 September 2023
Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7780349
14 September 2022
Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7535234
23 November 2021
Administrative Inspection · Deficiency Check · Examination of Repairs
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7356486
8 November 2021
Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7335441
21 July 2021
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7264055
22 June 2021
In-Service Inspection · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7218338
19 April 2021
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7178086
12 April 2021
MTSA Verification · Administrative Inspection · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7173324
2 June 2020
Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6966278
11 March 2020
DAPI Audit · MTSA Verification · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6918710
16 January 2020
Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6890522
19 April 2019
Annual Inspection · DAPI Audit · Administrative Inspection · MTSA Verification · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6665624
13 June 2018
Annual Inspection · MTSA Verification · Administrative Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6443045
11 January 2018
Drydock Exam · Administrative Inspection · Deficiency Check · Examination of Repairs · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6332404
20 April 2017
MTSA Verification · Annual Inspection · Deficiency Check · Administrative Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6117763
2 June 2016
In-Service Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5894771
8 January 2016
Drydock Exam · Examination of Repairs · Damage Survey · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5793477
2 December 2015
COI Inspection · MTSA Verification · Deficiency Check · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5773534
22 July 2015
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5192361
10 January 2012
MTSA Verification · DAPI Audit · COI Inspection · Deficiency Check · Hull Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4219974
2 December 2010
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3913545
24 November 2010
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3898353
19 March 2010
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3698817
2 March 2010
Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3686085
28 January 2010
Internal Structural Exam · Damage Survey · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3672046
23 January 2010
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3669265
15 April 2009
MTSA Verification · Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3451594
4 March 2009
Deficiency Check · Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3427895
23 January 2009
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3398829
4 March 2008
MTSA Verification · Deficiency Check · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3157506
9 March 2007
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2884919
5 March 2007
In-Service Inspection · MTSA Verification
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2881755
10 January 2007
Inclining Experiment · Initial Certification · Construction Oversight
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2859887
22 November 2005
Administrative Inspection
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2874926
Deficiency record · 115
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 30 April 2026
Resolved
At each initial and subsequent inspection for certification, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment, to include inspection and testing of smoke and fire detecting systems (including sensors and alarms). MI was not able to verify operation of the fire detection system due to inoperability of the fire detection panel.
46 CFR 115.810(a)(7)
701 c
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 30 April 2026
Resolved
All escape hatches and other emergency exits used as means of escape must be marked. MI observed the emergency exit signs in the in areas below not visible.
46 CFR 122.606
16 c
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 30 April 2026
Resolved
Tubular gauge glasses, if fitted to diesel fuel tanks, must be of heat resistant materials, adequately protected from mechanical damage. MI observed tubular gauge glasses on the fuel tanks did not have protection from mechanical damage.
46 CFR 119.440(a)(7)
16 C
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 30 April 2026
Resolved
Each vessel must be provided with a visual and audible alarm at the operating station to indicate a high water level in each unmanned space/s. MI observed the bilge high level alarms visual indicating lights illuminated all location when specific location where tested.
46 CFR 119.530
16 C
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 30 April 2026
Resolved
A fire control plan must be posted on the vessel in a location that is accessible and visible to all passengers. The plan must show escape routes, areas of refuge, embarkation stations, the location of fire protection/emergency equipment, compartment titles and hazard classification of accommodation and service spaces, and structural fire protection boundaries. MI observed the FCP did not reflect actual locations of items on the vessel.
46 CFR 116.530
16 C
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 30 April 2026
Resolved
Rails or equivalent protection must be installed near the periphery of all decks of a vessel accessible to passengers or crew. Equivalent protection may include lifelines, wire rope, chains, and bulwarks, that provide strength and support equivalent to fixed rails. Deck rails must include a top rail with the minimum height required by this section, and lower courses or equivalent protection as required by this section. MI observed main deck emergency exits accessible to passengers and or crew did not have rails or equivalent protection to prevent falling overboard.
46 CFR 116.900(a)
701 C
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 30 April 2026
Resolved
For each watertight door which is in a required subdivision bulkhead, an indicator light must be installed in the pilothouse and at each other vessel operating station from which the door is not visible. The indicator must show whether the door is open or closed. MI observed the indicator mechanism on the door was not permanently attached.
46 CFR 170.270 (e)
16 C
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 15 September 2025
Resolved
The owner, managing operator, or a qualified servicing facility as applicable shall conduct the following inspections and tests: For portable fire extinguishers, the inspections, maintenance procedures and hydrostatic pressure tests required by NFPA 10, (incorporated by reference, see subpart 114.600 of this chapter) with the frequency speified by NFPA 10. All fire extinguishing equipment, both fixed and portable, is overdue for annual servicing. Rectify prior to carrying passengers.
46 CFR 115.810(b)(1)
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 15 September 2025
Resolved
Each vessel that operates on the high seas must have on board an FCC Type Accepted Category 1, 406 MHz EPRB, installed and automatically float free and activate. The EPIRB battery expired in MAY2024. Vessel is restricted to 3 nautical miles from shore.
46 CFR 117.64
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 September 2025
Resolved
All cable and wire must Be installed with metal supports spaced not more than 610 millimeters (24 inches) apart, and in such a manner as to avoid chafing and other damage. The use of plastic tie wraps must be limited to bundling or retention of multiple cable installations, and not used as a means of support. There are multiple wire runs on the uper deck overhead secured by plastic wire zip ties.
46 CFR 120.340(b)(4)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 18 September 2024
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspection of electrical equipment and systems. Inspection of rotating electrical machinery essential to the routine operation of the vessel. The STBD generator had some kind of corrosion/liquid dripping from inside the winding housing. If not addressed, could cause an electrical/fire hazard. Windings need to be cleaned and verified that oil/liquid is not getting inside the winding housing.
46 CFR 115.806(d)
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 18 September 2023
Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board an FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate.MI observed that the EPIRB registration was expired. Vessel is restricted to operating no more than 3 miles from shore until deficiency is corrected.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 18 September 2023
Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board an FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate.
MI observed the hydrostatic release on the EPIRB was expired. Vessel is restricted to operating no more than 3 miles from shore until deficiency is corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 September 2023
Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment, other than small buoyancy compartments, under all practicable conditions. Sluice valves are not permitted in watertight bulkheads. MI observed crew unable to gain suction from the forward most compartment. System was proven to be functional. Operator needs to demonstrate that they can take suction from the forward compartment.
01 - Certificates & Documentation › 012 - Crew Certificates › Manning specified by the minimum safe manning doc
Issued 18 September 2023
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 23 November 2021
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. Modifications were made to the vessel without the approval of the cognizant OCMI. Provide documentation for review/approval.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 23 November 2021
Resolved
The MSC will determine whether calculations alone are
sufficient, in lieu of a stability test or deadweight survey, based on the accuracy of the
calculations and/or the application of appropriate conservative assumptions in vertical
center of gravity (VCG).
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 November 2021
Resolved
All unfired pressure vessels must be installed to the satisfaction of the OCMI. Provide manufacturer documentatjion to ensure pressure vessel in engine room space meets type approval.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 19 May 2021
Resolved
46 CFR 118.400(e)(1) Each accommodation space, control space and service must be fitted with a detection system of a type approved by the Commandant and installed in accordance with 46 CFR 76. Vessel's fixed fire detection system did not operate as approved and installed.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 19 May 2021
Resolved
46 CFR 118.300(b) The fire pump must be capable of delivering a singel hose stream from the highest hydrant, through the hose and nozzle , at a pitot tube pressure of 50psi. Packing at valve six (6) off of fire pump insufficient and leaking.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 19 May 2021
Resolved
46 CFR 116.500(j) A means of escape that is not readily apparent to a person from both inside and outside the space must be adequately marked. All interior exits to muster area are unmarked.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 19 May 2021
Resolved
46 CFR 122.520(a); 46 CFR 122.524(b) The master shall conduct sufficient drills and give sufficient instructions to make sure that all crew members are familiar with their duties during emergencies. A fire drill must be conducted at least once each month.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 19 May 2021
Resolved
46 CFR 119.465(h) Provision must be made for closing all supply ducts for a space protected by a fixed gas detection system. Vent closure for bow thruster unable to remain closed.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 12 April 2021
Resolved
A certificate of inspection is valid for 5 years. COI expired 29MAR2021. Vessel must renew COI prior to the carriage of passengers. Submit an application for inspection to schedule COI renewal.
46CFR115.107
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 11 March 2020
Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. The bow thruster diesel prime mover was leaking fuel oil at the # 1-3 injectors. Repair prior to use. - 46 CFR 119.100
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 March 2020
Resolved
Each life buoy on a vessel must be approved in accordance with 160.050 in subchapter Q of this chapter. The two life buoys grab lines on the bridge wings were deteriorated and no longer serviceable. Replace. - 46 CFR 117.70(b)(1)
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 11 March 2020
Resolved
The EPIRB test shall be logged or other wise documented. The test of the EPIRB were not being logged. - 46 CFR 122.728(c)
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 11 March 2020
Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 2 inches high "EMERGENCY EXIT, KEEP CLEAR". Three emergency exits signs were missing on the main deck. - 46 CFR 122.606
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 March 2020
Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. The flexible exhaust cooling water hose on bow thruster engine was chaffed/worn to the interior wires. Replace. - 46 CFR 119.100
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 11 March 2020
Resolved
Each entrance to a space storing carbon dioxide cylinders, a space protected by carbon dioxide system, or any space into which carbon dioxide might migrate must be conspicuously marked as follows: "CARBON DIOXIDE GAS CAN CAUSE INJURY OR DEATH. WHEN ALARM OPERATES, DO NOT ENTER UNTIL VENTILATED. LOCK OUT SYSTEM WHEN SERVICING." This warning is missing from the entrance to the engine room. - 46 CFR 122.612(i)
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 11 March 2020
Resolved
Vessels operated solely within 20 nautical miles of land must be equipped with VHF-DSC radiotelephone installation meeting the requirements of 80.1101(c)(2). The VHF-DSC radio did not have GPS location input. - 46 CFR 121.502 -> 47 CFR 80.905(a)(1)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 19 April 2019
Resolved
Each vessel must be provided with a bilge pump. Bilge pump must have the capacity to develop a suction velocity of not less than 400feet per minute through the size of bilge main piping. Bilge pump did not develop proper suction capacity. Bilge pump will need to be repaired or replaced.
46 CFR 119.520a
46 CFR 56.50-55c
Action: 17c
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 19 April 2019
Resolved
Each vessel must have adequate emergency lighting fitted along the line of escape to the main deck from all passenger and crew accommodation spaces located below the main deck. Observed extinguished light bulb on the 3rd deck emergency lighting fixture. Replace light bulb.
46 CFR 120.432a
Action: 16c
Operations/Management › Drills/Instruction › Not Conducted
Issued 25 June 2018
Resolved
Vessel require to perform Man Over Board Drill, vessel not ready to perform MOB drill, show vessel capability to perform MOB to the satisfaction of attending marine inspector.
46 CFR 115.808(g)
Electrical › Lighting (emergency) › Lighting Fixture
Issued 25 June 2018
Resolved
Each vessel must have adecuate emergency light to the main deck, emergency lights not working, show proper operation of E-light to attending marine inspector satisfaction. 46 CFR 120.432(a)
Stability › Watertight Integrity › General
Issued 25 June 2018
Resolved
Class 3 watertight doors must have instructions, instructions missing in the outside of the door, provide instructions to the satisfaction of attending marine inspector.
46 CFR 170.270
Fire Fighting › Fixed CO2 Fire Extinguishing System › Tanks
Issued 25 June 2018
Resolved
Fixed fire system must be approved by the Commandant, fixed fire system bottle due inspection for hydrostatic test, provide prove of hydro test to the satisfaction of attending marine inspector. 46 CRF 147.60
Communications › Radio Communications › VHF Radiotelephone
Issued 25 June 2018
Resolved
Emergency Broadcast Placard must be posted, emergency BP missing, provide EBP to the satisfaction of attending marine inspector. 46 CFR 121.506
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 11 January 2018
Resolved
Make repairs to wasted and holded exhaust piping, as identified, on port main diesel engine. 46CFR119.430
Fire Fighting › Remote Fuel Shutoff › General
Issued 20 April 2017
Resolved
Prove proper operation of emergency fuel shut off valves IAW 46 CFR 119.455
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 20 April 2017
Resolved
Replace grab lines on life-ring buoys (3) IAW 46 CFR 117.70
Lifesaving › Lifebuoys › Stowage
Issued 20 April 2017
Resolved
Properly replace retro-reflective tape on STBD life ring, located on bridge wing IAW 46 CFR 117
Electrical › Electrical Distribution System (service) › Wiring
Issued 20 April 2017
Resolved
Remove all dead end wires and twist on connectors located under control console on bridge and machinery space IAW 46 CFR 120.340
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 20 April 2017
Resolved
Properly label life jacket stowage with correct amount on deck 3 IAW 46 CFR 117.78
Communications › Radio Communications › VHF Radiotelephone
Issued 20 April 2017
Resolved
Properly import MMSI number into VHF class D radio and demonstrate radio is interfaced with GPS IAW 47 CFR part 80
Fire Fighting › Means of Escape › Escape Route Signs
Issued 20 April 2017
Resolved
Properly mark all emergency exits IAW 46 CFR 122.606
Electrical › Lighting (emergency) › Lighting Fixture
Issued 8 June 2016
Resolved
Emergency light in Captain stateroom is inoperable. Maek reapirs to the satisfaction of the attending MI. 46 CFR 120.432
Communications › Radio Communications › EPIRB
Issued 8 June 2016
Resolved
Provide proof of EPIRB registration. 47 CFR 80
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 8 June 2016
Resolved
Indicator light in pilot house for the engine room is inoperable. 46 CFR 170.270 (e)
Construction/Loadline › Hull › Bottom Plating
Issued 12 January 2016
Resolved
Provide repair proposal for the cracks found in the hull forward of both the port and starboard rudders. 46 CFR 115.700
Construction/Loadline › Hull › Bottom Plating
Issued 12 January 2016
Resolved
Provide approval letter from MSC for the structural modifications to strengthen the hull area around the rudders ref'ed on plans dtd 04/05/05 Bottom Plan and Shell Expansion. 46 CFR 115.700
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 12 January 2016
Resolved
Make proper repairs to the cracked swash bulkhead/baffle in starboard aft fuel tank, outboard of the rudder post. 46 CFR 115.700
Construction/Loadline › Hull › Bottom Plating
Issued 12 January 2016
Resolved
Provide repair proposal & make repairs to the wasted hull plate area located in the starboard aft fuel tank, inboard side aft of frame 45. 46 CFR 115.700
Fire Fighting › Fixed CO2 Fire Extinguishing System › Tanks
Issued 12 January 2016
Resolved
CO2 Fire Suppression Sys was disassembled for the hull repair. Reinstall and prove proper operation to the satisfaction of the Coast Guard. 46 CFR 118.410
Construction/Loadline › Hull › Bottom Plating
Issued 8 January 2016
Resolved
Make proper repairs to the cracked hull plating forward of both port and starboard rudders at Frame 45. 46 CFR 115.700
Fire Fighting › Means of Escape › Emergency Lighting
Issued 2 December 2015
Resolved
Provide emergency lighting, adequate for emergency egress, throughout deck 1.
Documentation › Certificates/Documents › Stability Letter
Issued 2 December 2015
Resolved
Post all required documentation in wheel house.
Communications › Public Address System › Loudspeaker
Issued 2 December 2015
Resolved
Provide adequate audible public announcement horns on aft 2nd, 3rd, and steering deck.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 2 December 2015
Resolved
Provide flat black running light paint.
Construction/Loadline › Hull › Hull Plating
Issued 10 January 2012
Resolved
Make under body hull available for inspection.
Construction/Loadline › Penetrations › Valve Flange
Issued 10 January 2012
Resolved
Make all through hull fittings within 6 inches of the deepest water load line available for inspection.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 10 January 2012
Resolved
Mechanically fasten Port MDE fuel emergency shut-off valve linkage.
Engineering › Sea-water System (primary cooling) › Valve
Issued 10 January 2012
Resolved
Replace or make repairs to the STBD MDE sea chest valve.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 10 January 2012
Resolved
Secure engine room distribution panel P1 circuit breaker connections/bus bar. Breakers are extremely Loose.
Electrical › Electric Supply System (service) › Cable
Issued 10 January 2012
Resolved
Make proper splice and remove all twist on wire nuts to all bilge high level alarms throughout vessel.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 10 January 2012
Resolved
Relocate DVD player bracket in the 2nd deck dining room Port A/C closet for access to A/C controller.
Electrical › Electric Supply System (service) › Battery Installation
Issued 10 January 2012
Resolved
Properly secure pilot house battery storage box.
Engineering › Bilge Water Management System › Strainer
Issued 10 January 2012
Resolved
Replace wasted and holed bilge strainers in the forward peak and forward storage compartments.
Engineering › Thrusters › Shaft
Issued 10 January 2012
Resolved
Replace missing bolt for bow thruster shaft.
Accommodation/Occupational Safety › Cooking Systems › Cooking Fuel
Issued 10 January 2012
Resolved
Remove propane tanks and grill from vessel.
Construction/Loadline › Hull › Bottom Plating
Issued 10 January 2012
Resolved
Provide a Marine Chemist Certificate for the Port fuel tank safe for entry/hotwork and make available for inspection prior to comencing repairs. Crop and renew with min 18X18 inch insert IWO 14 inch crack on the fwd lbottom eading edge of the Port fuel tank.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 10 January 2012
Resolved
Provide copy of tidal current tables for operating area.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 10 January 2012
Resolved
Replace expired items in First-Aid kit.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 10 January 2012
Resolved
Replace expired Alcohol swabs.
Stability › Watertight Integrity › General
Issued 10 January 2012
Resolved
Replace missing WTD selector switch outside the mid stateroom.
Communications › Public Address System › Loudspeaker
Issued 10 January 2012
Resolved
Repair Main Deck AFT PA speaker.
Fire Fighting › Fixed Fire Detection System › Approval
Issued 10 January 2012
Resolved
Smoke & Heat detectors located in galley, 2nd deck, 3rd deck & pilot house do not match the FCP. Update the FCP to match existing location & number of detectors. Provide approved plan for heat detectors in galley.
Fire Fighting › Structural - A Class Divisions › Accommodation Spaces
Issued 28 January 2010
Resolved
Replace all A-60 insulation saturated with water in the over head on the main deck port side aft prior to carrying passengers.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 28 January 2010
Resolved
Due to flooding after the grounding demonstrate proper operation of all electrical systems prior to carrying passengers. This includes but is not limited to the following systems: Fire pumps,Bilge pumps,Main propulsion engines including all the electrical control systems,Ships service generators,Electrical distribution and supply systems,Fire and smoke detection systems,Steering & navigation
Engineering › Fuel Oil Service System › Valve
Issued 15 April 2009
Resolved
Repair engine fuel shut offs
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 15 April 2009
Resolved
Add chain on stern railing and mark crew only on stern doors
Electrical › Electric Supply System (service) › Battery Conductor
Issued 15 April 2009
Resolved
Remove wing nuts on battery
Navigation › Piloting/Steering › Coast Guard Light List
Issued 15 April 2009
Resolved
Provide up to date navigation pub, coast pilot, tide tables and light list
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 15 April 2009
Resolved
Replace expired items in first aid kit
Communications › Radio Communications › EPIRB
Issued 15 April 2009
Resolved
Replace expired hydrostatic release on EPIRB
Documentation › Logs/Records › Logbook (official)
Issued 15 April 2009
Resolved
Establish method of posting passengers count shoreside
Operations/Management › Drills/Instruction › Fire
Issued 15 April 2009
Resolved
Provide up to date training log
Documentation › Logs/Records › Drug Test Records
Issued 15 April 2009
Resolved
Provide proof of drug enrollment for all crewmembers and proof of MIS report submittal.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 15 April 2009
Resolved
Post COI, stability letter, emergency broadcast placard and COD
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 15 April 2009
Resolved
Provide valid FCC marine operator permit
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 4 March 2008
Resolved
Provide current Certificate of Documentation
Documentation › Certificates/Documents › FCC SSL
Issued 4 March 2008
Resolved
Provide FCC Bridge to Bridge Certificate
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 4 March 2008
Resolved
Provide current contract with drug consortium ADIS to include covered employees. Provide company employee list with dates of hire and SSNs.
Communications › Radio Communications › EPIRB
Issued 4 March 2008
Resolved
Properly log EPIRB tests.
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 4 March 2008
Resolved
Provide means to file voyage plan and provide means to file passenger count on pier.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 4 March 2008
Resolved
Provide screens for navigation lights as per COLREGS.
Fire Fighting › Fire Pumps › Pressure
Issued 4 March 2008
Resolved
Provide pressure gauge for fire pump discharge or prove 50 PSI at nozzle.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 4 March 2008
Resolved
Provide current or corrected paper charts, coast pilot, lightlist and current tables.
Documentation › Logs/Records › Drug Test Records
Issued 5 March 2007
Resolved
Provide proof of Drug Program enrollment of 5 deckhands & 1 Mate or Senior deckhand.
Accommodation/Occupational Safety › Ventilation › General
Issued 5 March 2007
Resolved
Prove proper installation of authorized exhaust (metallic) for clothes dryer. Found plastic exhaust in use.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 5 March 2007
Resolved
Provide latch for oven door.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 5 March 2007
Resolved
Secure meat cutter to table.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 5 March 2007
Resolved
Secure hot water tanks.
Lifesaving › Embarkation Appliances/Stations › Designated Location
Issued 5 March 2007
Resolved
Provide signage for emergency escape routes and exits.
Lifesaving › Embarkation Appliances/Stations › Accessability
Issued 5 March 2007
Resolved
Unblock emergency escape on portside.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 5 March 2007
Resolved
Starboard generator is missing protective cover.
Electrical › Lighting (service) › Lighting Fixture
Issued 5 March 2007
Resolved
Wire supplying Palm Tree decoration is loose (extension cord) & not hard wired.
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 5 March 2007
Resolved
Flammables found loose and not stored in authorized flammables storing area.
Lifesaving › Visual Distress Signals (General) › Marking
Issued 5 March 2007
Resolved
EPIRB found w/out hydrostatic release expiration date and is not registered.
Fire Fighting › Ventilation Systems › Ducts
Issued 5 March 2007
Resolved
Vent closures not marked on starboard aft engine room.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 5 March 2007
Resolved
Emergency lights in stairwell adjacent to galley inop.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 5 March 2007
Resolved
Mount Fire Ctrl Plans on all decks.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 2 February 2007
Resolved
Apply a non-skid / non-slip surface to all inclined stairs on the vessel.
Documentation › Certificates/Documents › Stability Letter
Issued 2 February 2007
Resolved
Post the vessel Stability Letter issued by the CG Marine Safety Center. Mark the maximum number of passengers permitted on the upper decks in accordance with the Stability Letter.
Operations/Management › Drills/Instruction › Fire
Issued 10 January 2007
Resolved
In the presence of a Coast Guard Marine Inspector, conduct a fire and abandon ship drill. Conduct a man overboard drill.
Casualty record · 1
23 January 2010Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 3669265
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Recorded names · 1
SIR WINSTON (2010). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.