MAURY USCG vessel records Sign in
← All vessels

ARIANA

ARIANA is a 2006 freight ship. The Coast Guard has recorded 9 inspections since 2006, most recently in September 2022, along with 4 deficiencies and 1 operational control.

Records from 2006 to 2022. Most recent: inspection, 22 September 2022.

Built
2006
Last inspected
22 September 2022
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9327671 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
839355
Flag
PORTUGAL
—
Maury page id
psix-839355

Inspections, by type

…with no type recorded2
Years with a record 4 calendar years (2006–2022)
The 9 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it32161 - Convention (Subpart B), Gross Ton
38616 - Dead Weight, Metric Ton
52190 - Displacement, Metric Ton
12604 - Convention (Subpart B), Net Ton
32161 - Simplified, Gross Ton
12604 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 9

22 September 2022 PSC B · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7564077
9 May 2022 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7446578
2 May 2022 PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7442073
28 April 2022 Deficiency Check · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7439825
2 June 2012 Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4331682
2 February 2007 Type not recorded
No type recorded · Station Little Creek · USCG East District (CGD-E) · Activity 2866971
22 August 2006 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2755746
26 July 2006 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2725617
25 July 2006 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2724838

Deficiency record · 4

10 - Safety of Navigation › N/A - No Subsystem › Voyage data recorder (VDR)/Simplified Voyage data recorder(S-VDR)
Issued 22 September 2022 Resolved
The voyage data recorder system, including all sensors, shall be subjected to an annual performance test. The test shall be conducted by an approved testing or servicing facility to verify the accuracy, duration and recoverability of the recorded data. PSCO observed voyage data recorder annual service/test expired on 24MAY2022. 74 SOLAS (2020) V/18.8
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 22 September 2022
Resolved 24 September 2022
Resolution: Class report recieved from lloyds register. VDR has undergone performance test.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 2 May 2022 Resolved
11104 - Rescue boats shall be stowed in a state of continuous readiness for launching in not more than five minutes. PSCO observed rescue boat covered, davit launch unattached, and gas tank missing. Crew members spent approximately 25 minutes preparing the rescue boat to start. 74SOLAS(20)III/14.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 2 May 2022
Resolved 9 May 2022
Resolution: For emergency preparedness aims, shelter cover was removed, gas tank was constantly installed on boat and davit launch was attached at all times for operation
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 May 2022 Resolved
13101 - The condition of the ship and it's equipment shall be maintained to conform with the provisions of the present regulations. PSCO observed jacket water actively leaking from the NO. 1 cylinder on the main engine. 74SOLAS(20)I/11(A)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 2 May 2022
Resolved 9 May 2022
Resolution: Main engine cylinder unit no:1 was found overhauled by ship s crew on 2022-05-04. Subject unit was checked by undersigned surveyor after overhaul and found tight under normal working pressure of jacket cooling water .
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 26 July 2006 Resolved
VESSELS OILY WATER SEPERATOR INOPERABLE DUE TO FAULTY CONTROL PANEL.
Action required: 705 - Other - as specified
Due 6 August 2006
Resolved 22 August 2006
Resolution: As per class report; OWS has been repaired and tested satisfactory.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.