Records from 2006 to 2025. Most recent: inspection, 12 August 2025.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 28
12 August 2025
COI Inspection · Deficiency Check
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8205689
2 October 2024
Drydock Exam
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8013454
30 September 2024
Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8013438
31 October 2023
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7818460
9 November 2022
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7592159
21 September 2022
Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7563974
1 September 2021
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7336061
28 September 2020
Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7067128
19 August 2020
Administrative Inspection · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7036726
14 August 2020
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7033193
5 February 2019
Deficiency Check · COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6619967
24 September 2018
Administrative Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6545900
4 December 2017
Deficiency Check · Annual Inspection · Hull Examination · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6316546
16 December 2016
Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6069009
6 September 2016
Drydock Exam · Administrative Inspection · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5989166
7 December 2015
Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5794194
21 July 2015
DAPI Audit
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5191861
10 October 2014
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5100780
16 September 2011
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4147034
1 September 2011
COI Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4133041
30 August 2011
DAPI Audit
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4143623
10 November 2010
Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3889004
24 September 2010
Hull Examination · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3844379
22 December 2009
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3652175
22 September 2008
Hull Examination · Internal Structural Exam · Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3320370
21 November 2007
Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3102293
5 October 2006
In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2888950
28 September 2006
Initial Certification · Simplified Stability Test · Initial Construction-Excluding Oversight
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2779255
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 12 August 2025
Resolved
Pre-engineered gas system not meeting the following requirements:
-Must have an audible alarm that sounds upon discharge at operators station.
Must make repairs to satisfaction of USCG Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 September 2025
Resolved 26 September 2025
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 August 2025
Resolved
Crew training on vessel emergency instructions is required during the following timeframes:
-upon first time being employed and prior to getting underway.
-at least once every three (03) months.
Vessel logs indicated crew training on vessel emergency instructions conducted once every six (06) months. Corrected on the spot.
Action required: 10 - Deficiency Rectified
Resolved 12 August 2025
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 14 August 2020
Resolved
VESSEL MUST UNDER GO AN ANNUAL INSPECTION WITHIN THE 3 MONTHS BEFORE OR AFTER EACH ANNIVERSARY DATE. VESSEL DID NOT CONDUCT THE 1ST ANNUAL INSPECTION WITHIN THE 6 MONTH WINDOW.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 August 2020
Resolution: Vessel conducted a COI exam.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 February 2019
Resolved
ADEQUATE SERVICEABLE PORTABLE FIRE EXTINGUISHERS ARE TO BE INSTALLED ONBOARD THE VESSEL.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 February 2019
Resolution: Marine Inspector verified properly serviced fire extinguishers were installed onboard vessel.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 5 February 2019
Resolved
PROVIDE PROOF OF SERVICING THE VESSEL EPIRB SHOWING A VALID BATTERY EXPIRATION DATE.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2019
Resolved 7 February 2019
Resolution: Marine Inspector verified valid battery on EPIRB.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 5 February 2019
Resolved
PROVIDE PROOF OF CARRYING A VALID FCC RADIO SAFETY CERTIFICATE. 47CFR13.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2019
Resolved 23 May 2019
Resolution: Vessel representative provide Marine Inspector with valid FCC Radio Safety Certificate.
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 5 February 2019
Resolved
A LANYARD TO THE APPROPRIATE LENGTH SHALL BE AFFIXED TO THE VESSEL'S RING BUOY.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2019
Resolved 14 March 2019
Resolution: Marine Inspector verified vessel's ring buoy having required length of lanyard attached.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 5 February 2019
Resolved
ENSURE ALL LIGHTING ARRANGEMENTS ARE IN WORKING ORDER FOR THE NAVIGATION LIGHTS.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2019
Resolved 14 March 2019
Resolution: Marine Inspector verified proper working navigation lights aboard vessel.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 5 February 2019
Resolved
SHOW PROOF OF HAVING THE CURRENT YEAR TIDE TABLE ONBOARD THE VESSEL.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2019
Resolved 14 March 2019
Resolution: Marine Inspector verified vessel having current year's tide table onboard vessel.
Engineering › Fuel Oil Service System › Valve
Issued 4 December 2017
Resolved
Vessel needs to have its fuel shut off remote valves in satisfactory working order.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 December 2017
Resolution: The company demonstrated properly operating fuel shut-off valves.
Communications › Alarms/Indicators › Bilge Alarm
Issued 4 December 2017
Resolved
Vessel needs to have all audible indicators working for the high bilge alarms.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 December 2017
Resolution: The vessel's high bilge audible indicators are in working order.
Operations/Management › Drills/Instruction › Not Conducted
Issued 4 December 2017
Resolved
Vessel needs to perform satisfactory drills with an attending Marine Inspector.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 December 2017
Resolution: The vessel performed satisfactory drills with an attending Marine Inspector.
Communications › Alarms/Indicators › Bilge Alarm
Issued 4 December 2017
Resolved
Vessel needs to have the engine room bilge pump operate in manual mode.
Condition: Invalid
Action required: 705 - Other - as specified
Due 24 December 2017
Resolved 5 December 2017
Resolution: The engine room bilge manual indicators are in working order.
Communications › Radio Communications › EPIRB
Issued 4 December 2017
Resolved
Vessel needs a renewed hydrostatic release unit for its EPIRB.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 December 2017
Resolved 5 December 2017
Resolution: The company installed a new EPIRB hydrostatic release.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 4 December 2017
Resolved
Vessel needs to stencil the ring buoy with the vessel's name.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 December 2017
Resolved 5 December 2017
Resolution: The vessel's name has been stenciled on the ring buoy.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 4 December 2017
Resolved
Vessel needs to properly mark the location of the adult lifejackets with the quantity.
Condition: Invalid
Action required: 705 - Other - as specified
Due 24 December 2017
Resolved 5 December 2017
Resolution: The company marked the location of the lifejackets with the corresponding quantity.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 4 December 2017
Resolved
Vessel needs to renew the eye wash.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 December 2017
Resolved 5 December 2017
Resolution: The company put new eye wash solution onboard the vessel.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 4 December 2017
Resolved
Vessel needs to post in-water emergency procedures.
Condition: Invalid
Action required: 705 - Other - as specified
Due 24 December 2017
Resolved 5 December 2017
Resolution: The company posted new in-water emergency procedures onboard the vessel.
Communications › Radio Communications › VHF Radiotelephone
Issued 6 September 2016
Resolved
Vessel needs to be equipped with an approved "Class D" or better VHF-DSC radio that is capable of integral gps capabilities or is connected to an electronic position fixing device. 47 CFR 80.905(a)(1)
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 December 2016
Resolved 15 December 2016
Resolution: Vessel rep emailed pictures of the installed Class "D" radio onboard the vessel showing the GPS coordinates displayed on the radio screen. All sat.
Engineering › Bilge Water Management System › Pump
Issued 7 September 2011
Resolved
Prove proper operation of forward bilge pump. Bilge pump is not able to draw suction.
Due 14 September 2011
Resolved 13 September 2011
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 7 September 2011
Resolved
Arrange ring buoy with lifeline and floating waterlight IAW 46 CFR 180.70.
Due 14 September 2011
Resolved 13 September 2011
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 30 August 2011
Resolved
EAP Display Requirements - Missing
Due 30 September 2011
Resolved 18 October 2011
Resolution: EAP community service hot-line telephone number for crewmember assistance are included in the company policy and will now be posted in the monthly "shop notes."
Operations/Management › Drug and Alcohol Testing › Testing, Random
Issued 30 August 2011
Resolved
not conducting complete random testing, not completing 50% annual requirement. Expect company to explain how they will ensure that all parties of the drug testing pool are included in the random selection. Company needs to complete at least 8 more random tests for 2011 to be in compliance.
Due 30 September 2011
Resolved 10 January 2012
Resolution: Completed all required random drug tests for 2011.
Documentation › Logs/Records › MIS Form
Issued 30 August 2011
Resolved
MIS Form - Missing
Due 30 September 2011
Resolved 18 October 2011
Resolution: VSL Rep presented the 2010 MIS Form.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 30 August 2011
Resolved
EAP Training Requirements - Missing
Due 30 September 2011
Resolved 22 November 2011
Resolution: Purchased Training Material from Alpha Pro Solutions. Took supervisor training and trained staff
Fire Fighting › Fire Bucket › Quantity
Issued 29 November 2010
Resolved
Provide three fire buckets onboard in accordance with 46CFR181.60.
Due 29 December 2010
Resolved 3 December 2010
Communications › Radio Communications › EPIRB
Issued 29 November 2010
Resolved
Provide proof of current EPIRB registration.
Due 29 December 2010
Resolved 3 December 2010
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 29 November 2010
Resolved
Properly label adult/child lifejacket stowage in accordance with 46CFR180.78.
Due 29 December 2010
Resolved 3 December 2010
Fire Fighting › Fixed Fire Detection System › Approval
Issued 21 November 2007
Resolved
Provide proof of annual servicing on fixed and portable fire extinguishers.
Condition: Unknown
Due 5 December 2007
Resolved 24 December 2007
Resolution: Sighted tags from servicing company on portable and fixed firefighting bottles.
Documentation › Certificates/Documents › FCC SSL
Issued 21 November 2007
Resolved
Provide valid FCC Safety Radio Certificate
Condition: Unknown
Due 28 November 2007
Resolved 5 May 2008
Fire Fighting › Fire Bucket › Availability
Issued 21 November 2007
Resolved
Provide (1) additional 2.5 gallon fire bucket with marking and lanyard.
Condition: Unknown
Due 5 December 2007
Resolved 24 December 2007
Resolution: Sighted (3) 2.5 gallon fire buckets with lanyards.
Documentation › Certificates/Documents › Stability Letter
Issued 21 November 2007
Resolved
Post and have on board original Stability Letter.
Condition: Unknown
Due 5 December 2007
Resolved 5 May 2008
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 21 November 2007
Resolved
Provide original valid Certificate of Documentation.
Condition: Unknown
Due 5 December 2007
Resolved 24 December 2007
Resolution: Sighted original Certificate of Documentation on vessel.
Lifesaving › Hand Flares › Quantity
Issued 21 November 2007
Resolved
Provide (6) red flares and (6) ornage smoke flares. Vessel is prohibited from carrying passengers until this deficiency has been corrected.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 November 2007
Documentation › Certificates/Documents › FCC SSL
Issued 21 November 2007
Resolved
Provide original FCC Station License
Condition: Unknown
Due 5 December 2007
Resolved 21 December 2007
Resolution: Sighted original FCC Station license.