← All vessels
NENITA
Freight Ship · Bulk Carrier class · Built 2000s · USCG Northwest District (CGD-NW) · Other hulls named NENITA
NENITA is a 2006 freight ship. The Coast Guard has recorded 16 inspections since 2006, most recently in November 2021, along with 10 deficiencies and 2 operational controls.
Records from 2006 to 2021. Most recent: operational control imposed, 25 November 2021.
- Built
- 2006
- Last inspected
- 25 November 2021
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 10 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9304289 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V7SY9
841194
Flag
MARSHALL ISLANDS
—
Maury page id
psix-841194
Inspections, by type
…with no type recorded5
Years with a record
10 calendar years (2006–2021)
The 16 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it25259 - Convention (Subpart B), Net Ton
87409 - Displacement, Ton
76807 - Dead Weight, Ton
40042 - Convention (Subpart B), Gross Ton
87409 - Displacement, Ton
76807 - Dead Weight, Ton
40042 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 16
25 November 2021
Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7357515
27 October 2020
PSC B
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7080877
15 June 2017
Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6156968
5 December 2016
Loadline Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6053444
19 November 2016
Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 6044218
19 November 2016
Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6046360
17 November 2016
Ballast Water Examination · Deficiency Check · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6035636
7 December 2015
ISPS II Exam · Ballast Water Examination · Deficiency Check · PII Safety Exam · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5773667
16 October 2014
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4999334
22 January 2009
Type not recorded
No type recorded · Station Little Creek · USCG East District (CGD-E) · Activity 3399840
7 July 2008
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3260142
29 November 2007
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 3106718
15 March 2007
Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2888231
8 March 2007
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2881982
13 September 2006
Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 2784641
7 August 2006
ISPS II Exam · Ballast Water Examination · MARPOL Annex V Examination · MARPOL Annex I Examination · PII Safety Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 2741853
Deficiency record · 10
07 - Fire Safety › N/A - No Subsystem › Jacketed high pressure lines and oil leakage alarm
Issued 27 October 2020
Resolved
01 - EXTERNAL HIGH-PRESSURE FUEL DELIVERY LINES BETWEEN THE HIGH-PRESSURE FUEL PUMPS AND FUEL INJECTORS SHALL BE PROTECTED WITH A JACKETED PIPING SYSTEM CAPABLE OF CONTAINING FUEL FROM A HIGH-PRESSURE LINE FAILURE. PSCO IDENTIFIED FUEL LEAKS ON THE NUMBER 7 HIGH PRESSURE FUEL LINE. 74solas(09) II-2/4.2.2.5.2. 17AC
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 17 November 2016
Resolved
1230 - Railing Cat Walks - Efficient guard rails shall be fitted to all exposed parts of the freeboard and supersturcture decks. Vessel is fitted with nylon rope in openings between guard rails. ICLL 66 Reg. 25.2, 17ac
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 17 November 2016
Resolved
0750 - Fire Prevention - Combustible materials were improperly stored in an engineering holding tank. 74 SOLAS (2009 Cons.) I/11.a, 17ac
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 17 November 2016
Resolved
0750 - Fire Prevention - The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: Structural fire protection including fire resisting divisions and protection of openings and penetrations in these divisions. The A60 insulation in the AC room was damaged. 74SOLAS(09) II-2/14-2.1.1.1 40AC
Electrical › Electric Generation Source (service) › Generator
Issued 7 December 2015
Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. ALL SHIP SERVICE GENERATORS WERE FOUND TO HAVE EXCESSIVE OIL LEAKAGE AND OIL SATURATED RAGS SURRONDING THE ENGINE BLOCKS.SOLAS74(14 CONS)CHAPI.REG.11a 17ac
Engineering › Sea-water System (primary cooling) › Piping
Issued 7 December 2015
Resolved
PSCOs OBSERVED 03 TEMPORARY REPAIRS. #1 OIL SERVICE PIPE BELOW THE DECK PLATES NEAR THE #4 CYLINDER COVER. #2 PIN HOLE LEAK AND PIPE PATCH ON THE PORT SIDE GREY WATER PIPE NEAR THE OVERBOARD DISCHARGE VALVE. #3-#1 SALT WATER COOLING PIPE HAD A PATCH WEDGED WITH A BROOM STICK RIGHT AFTER THE #1 SALT WATER COOLING PUMP. PIPE CONTINUES TO LEAK SUBSTANTIALLY. SOLAS 74(14CONS) CHAP. 1 REG. 11a 17ac
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 7 December 2015
Resolved
MEANS SHALL BE PROVIDED TO CONTROL LEAKS OF FLAMMABLE LIQUIDS. PSCO OBSERVED OIL SOAKED RAGS THROUGHOUT THE ENGINE ROOM. NO EVIDENCE OF HOUSE KEEPING WAS OBSERVED. SOLAS 74 (04 CONS) CHAP. II-2 REG. 4.1. 17ac
Documentation › Logs/Records › Oil Record Book
Issued 7 December 2015
Resolved
PSCO OBSERVED IN THE OIL RECORD BOOK PART I, ON 19OCT15, THE BILGE SEP. OIL TANK HAD 2.34m3 IN IT, ON 20OCT15, WITH NO DISCHARGE OR TRANSFER RECORDED, THE BILGE SEP. OIL TANK WAS LOGGED HAVING 2.07m3 IN IT. ADDITIONALLY, PSCO OBSERVED THE LEVEL OF THE BILGE TANK RISE 2.0m3 IN NOVEMEBER 2015 WITHOUT ANY TRANSFER ENTRIES MADE. MARPOL 73/78(2011) ANNEX I REG.17.3 17ac
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 7 December 2015
Resolved
SATISFACTORY MEANS IN THE FORM OF (GUARDRAILS, LIFE LINE, ETC.) SHALL BE PROVIDED FOR THE PROTECTION OF THE CREW IN GETTING TO OR FROM THEIR QUARTERS, MACHINERY SPACE, AND ALL OTHER PARTS USED IN THE WORK OF THE SHIP. 03 GUARDRAILS WERE OBSERVED BROKEN IN THE ENGINE ROOM CREATING AN UNSAFE WORK ENVIRONMENT. ICLL 66 REG.25 50ac
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 7 August 2006
Resolved
Vessel has no Non-Tank Vessel Response Plan. Submit Non-Tank Vessel Response Plan to U.S Coast Guard (G-PCV-1)
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.