← All vessels
AQUABUS II
Passenger (Inspected) · Passenger Ship class · Built 2000s · USCG Great Lakes District (CGD-GL) · Other hulls named AQUABUS II
AQUABUS II is a 2000 passenger vessel (inspected). The Coast Guard has recorded 30 inspections since 2000, most recently in June 2026, along with 35 deficiencies and 2 casualty investigations between 2007 and 2015.
Records from 2000 to 2026. Most recent: inspection, 10 June 2026.
- Built
- 2000
- Last inspected
- 10 June 2026
- Documentation
- Expired · documentation file of 10 September 2026
- Deficiencies
- 35 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 2 investigations · 2007–2015
Identity
1092980
WCZ8087
844
Flag
UNITED STATES
368385760
Maury page id
psix-844
Inspections, by type
…with no type recorded3
Years with a record
20 calendar years (2000–2026)
The 30 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)40.0 ft × 12.0 ft × 5.3 ft
Registered tonnagegross 17 / net 13
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWILLARD MARINE INC · ANAHEIM, CA, UNITED STATES · built 2000
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portERIE, PA
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it13 - Simplified, Net Ton
17 - Simplified, Gross Ton
17 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDP7883MMSI 368385760 · active · compulsorily equipped · granted 30 August 2024, expires 30 August 2034
WCZ8087MMSI 367442520 · expired · voluntarily equipped · granted 10 March 2010, cancelled 11 July 2020 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 30
10 June 2026
Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8463397
29 July 2024
Drydock Exam · Internal Structural Exam · COI Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7985657
5 August 2020
Administrative Inspection
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7024584
2 May 2019
Deficiency Check · Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6678171
16 May 2018
Deficiency Check · Administrative Inspection · COI Inspection · DAPI Audit
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6415828
28 August 2017
Administrative Inspection
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6253825
10 July 2017
DAPI Audit · Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6189799
2 June 2016
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5894759
6 October 2014
Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5000039
29 May 2014
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4873338
13 July 2012
Deficiency Check
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4528274
25 June 2012
DAPI Audit · Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4348248
13 June 2012
Simplified Stability Test
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4344982
20 December 2011
Administrative Inspection
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4211600
18 July 2011
Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4086396
9 January 2009
Administrative Inspection
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3391460
23 June 2008
Periodic Inspection · DAPI Audit
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3260695
6 July 2007
Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2996884
23 May 2007
Re-Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2939877
23 May 2006
Re-Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2657035
6 May 2005
COI Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 2367787
18 November 2004
Hull Examination
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 2263588
2 June 2004
Deficiency Check
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 2088451
18 May 2004
Re-Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 2070926
19 May 2003
Annual Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1794229
12 June 2002
Deficiency Check
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1629943
14 May 2002
Re-Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1616561
18 May 2001
Re-Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1460538
17 May 2000
Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1466141
1 February 2000
Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1048117
Deficiency record · 35
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 May 2019
Resolved
Provide clip with appropriate length of lanyard for ring buoy.
01 - Certificates & Documentation › 013 - Documents › Ship specific plans for the recovery of persons from the water
Issued 2 May 2019
Resolved
Post emergency procedures.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 2 May 2019
Resolved
Provide first-aid kit with required contents.
09 - Working and Living Conditions › 091 - Living Conditions › Record of inspection
Issued 2 May 2019
Resolved
Post all pages of the Certificate of Inspection.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 2 May 2019
Resolved
Prove proper operations of the Fire Boy system status lights. Both normal and override are extinguished.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 2 May 2019
Resolved
Provide three fire 2.5 gallon buckets w/attached lanyard of sufficient length, and marked as required with provided cite.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 2 May 2019
Resolved
Prove proper operation of the bow mounted side lights.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 2 May 2019
Resolved
Provide on board operable portable lights.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 May 2019
Resolved
Prove proper operation of the main diesel engine post repair of oil leaks. Ensure engine and bilge are clear from caked oil.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 22 May 2018
Resolved
Correct vessel trim prior to commercial operations iaw stability letter.
04 - Emergency Systems › N/A - No Subsystem › Location of emergency installations
Issued 22 May 2018
Resolved
Modify emergency procedures to reflect actual course.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 22 May 2018
Resolved
Plug bulkhead between engine room to pilot station to make vapor tight.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 22 May 2018
Resolved
Replace required contents of first aid kit with unexpired items.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 22 May 2018
Resolved
Post COI, stability letter and emergency instructions as required.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 16 May 2018
Resolved
Make rudder stop satisfactory as to not damage steering.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 10 July 2017
Resolved
Provide application for inspection providing requested route, manning & operators.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 10 July 2017
Resolved
Mark engine room ventilation closures "Fire Dampers" in 1" red block lettering.
Electrical › Electric Supply System (service) › Battery Installation
Issued 10 July 2017
Resolved
Provide battery box cover securing bolts.
Lifesaving › Hand Flares › Quantity
Issued 10 July 2017
Resolved
Provide appropriate hand flares for vessels route.
Engineering › Sea-water System (primary cooling) › Piping
Issued 10 July 2017
Resolved
Provide metal cap for water hose fitting attached to raw water intake line.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 10 July 2017
Resolved
Replace water light battery
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 10 July 2017
Resolved
Replace ring buoy line with appropriate type & length as provided within cite. 46 CFR 180.70
Lifesaving › Lifebuoys › Immediately Available
Issued 10 July 2017
Resolved
Relocate ring buoy, line & light to an accessible location. Demonstrate use as provided within vessel emergency procedures.
Electrical › Lighting (service) › Lighting Fixture
Issued 10 July 2017
Resolved
Prove proper operation of aft well deck passenger seating lights
Documentation › Markings/Placards › Warning Signs
Issued 10 July 2017
Resolved
Replace emergency broadcast placard.
Communications › Public Address System › Amplifier
Issued 10 July 2017
Resolved
Prove proper operations of aft intercom.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 10 July 2017
Resolved
Schedule follow up visit to demonstrate acceptable man-overboard recovery IAW cite.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 15 October 2014
Resolved
Aft water lubricated shaft bearing worn beyond 50% of original requiring replacement.
Electrical › Electrical Distribution System (service) › Grounding Conductor
Issued 15 October 2014
Resolved
Installed non-integral aluminum fuel tank is not electrically bonded to vessels bonding system. Install min 8AWG wire from fuel tank to vessels bonding system.
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 25 June 2012
Resolved
The heat detector for the engine compartment has been removed from the overhead. Replace with approved manufacturer equipment and prove proper operation in the presence of USCG Marine Inspector.
Documentation › Certificates/Documents › Stability Letter
Issued 20 December 2011
Resolved
Valid proof of stability cannot be provided to comply with new AAWPP of 185 lbs.
Provide valid proof of stability
Stability › Intact Righting Energy › General
Issued 9 January 2009
Resolved
Prior to operating outside of the waters of Presque Isle Bay, Erie Pennsylvania, provide proof of adequate stability for listed vessels to operate beyond a "Protected waters" stability route ("Partially Protected" or "Exposed" route).
Engineering › Diesel Engine (propulsion-direct drive)
Issued 18 May 2004
Resolved
Repair fuel leak on main engine injector pump prior to operating with passengers. LEGACY COMPONENT DESC: Injector (fuel injection)
Operations/Management › Drills/Instruction
Issued 16 May 2002
Resolved
Conduct drills in presence of Marine inspector.
Lifesaving › Lifejacket/PFD (General)
Issued 16 May 2002
Resolved
Segregate child size lifejackets from adult size.
Casualty record · 2
6 July 2007Routine · role: Involved in a Marine Casualty · activity 2996884
12 July 2015Routine · role: Moored/Anchored in Vicinity of Primary Subject · activity 5183375
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.