← All vessels
EVER SMILE
EVER SMILE is a 2006 freight ship. The Coast Guard has recorded 24 inspections since 2006, most recently in May 2025, along with 9 deficiencies and 1 operational control.
Records from 2006 to 2025. Most recent: inspection, 19 May 2025.
- Built
- 2006
- Last inspected
- 19 May 2025
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 9 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9300415 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
MLTH5
844246
Flag
UNITED KINGDOM
—
Maury page id
psix-844246
Inspections, by type
…with no type recorded6
Years with a record
12 calendar years (2006–2025)
The 24 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it39564 - Convention (Subpart B), Net Ton
78268 - Dead Weight, Metric Ton
107537 - Displacement, Metric Ton
76185 - Convention (Subpart B), Gross Ton
78268 - Dead Weight, Metric Ton
107537 - Displacement, Metric Ton
76185 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 24
19 May 2025
PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8137438
28 March 2025
PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8099192
23 March 2025
PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8096833
13 March 2024
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7877855
18 July 2023
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7745829
18 March 2022
PSC A
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7414358
11 March 2022
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7414053
2 January 2022
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7374627
28 July 2021
Deficiency Check · PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7267103
22 July 2021
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7264129
19 July 2019
ISPS II Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6745959
20 June 2018
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6450275
22 November 2017
ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6311664
8 June 2017
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6154795
1 June 2017
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6162360
18 April 2017
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6127313
23 March 2016
PI Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5836819
2 January 2009
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3385226
17 May 2007
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2936814
8 March 2007
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2883145
8 March 2007
Type not recorded
No type recorded · Maritime Safety & Security Team LA/LB (91103) · Activity 2884211
18 September 2006
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2781508
11 August 2006
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2744298
10 August 2006
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2742943
Deficiency record · 9
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 23 March 2025
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Upon inspection of all life rafts, PSCO found banding straps still attached from delivery installed, preventing proper inflation. SOLAS (20) III/20.2
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 March 2025
Resolved
Means shall be provided to control leaks of flammable liquids. PSCO identified excessive leaks on top and adjacent to the Primary Oily Water Tank, from the motor in the Elevator Machine Room, and from the oil filter on Generator #2. SOLAS (09) II-2/4.1.1
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 March 2025
Resolved
Electrical installations shall be such that the safety of passengers, crew, and ship from electrical hazards will be ensured. PSCO identified open switchboard with unapproved ventilation source in Elevator Machine Room. SOLAS (04) II-1/40.1.3
12 - Dangerous Goods › N/A - No Subsystem › Personal protection
Issued 23 March 2025
Resolved
The machinery ... shall be so installed and protected to reduce to a minimum any danger to persons on board, due regard being paid to moving parts. PSCO identified Skimmer for floating oil in Primary Oily Water Tank not installed IAW manufacturer's design. SOLAS (04) II-1/26.1
08 - Alarms › N/A - No Subsystem › Steering gear alarm
Issued 23 March 2025
Resolved
A low-level alarm for each hydraulic fluid reservoir ... shall be given on navigation bridge. No alarm for low-level hydraulic fluid given on navigation bridge for pump #1. SOLAS (04) II-1/29.12.2
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 23 March 2025
Resolved
Every steam pipe and every fitting connected thereto through which steam may pass shall be so designed, constructed, and installed as to withstand the maximum working stress to which it may be subjected. PSCO identified steam leak on pipe IWO purifier room above Low Sulfur HFO Settling Tank. SOLAS (04) II-1/33.1
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 23 March 2025
Resolved
Machinery spaces of Category A shall be adequately ventilated so as to ensure that when machinery or boilers therein are operating at full power in all weather conditions including heavy weather, and adequate supply of air is maintained. PSCO identified that manual louvers not open during operation of EDG despite clear signage to leave open for ventilation.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company verification, review and evaluation
Issued 23 March 2025
Resolved
The Company should establish procedures to ensure that the ship is maintained in conformity with the Provisions of the relevant rules and regulations. The above technical deficiencies, though of such a nature that do not warrant the detention of the ship, still indicate a failure or lack of effective implementation of the ISM Code related to onboard maintenance protocols. An internal audit of maintenance procedures is to be conducted and corrective actions implemented within three months from 24Feb2025 as required by Paris MoU Exam conducted in Hamburg, Germany. SOLAS (20) IX/3.1 ; ISM Code 10
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 28 July 2021
Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT CONVENTION TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT PRESENTING AN UNREASONABLE THREAT OF HARM TO THE MARINE ENVIRONMENT. PSCO NOTED DURING FUNCTION TEST OF THE EMERGENCY GENERATOR, VOLTAGE METER INDIACTED 320 VOLTS. PER MANUFACTURERS DATA PLATE, RUNNING VOLTAGE SHOULD BE 440 VOLTS.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.