Records from 2016 to 2025. Most recent: inspection, 19 May 2025.
Inspection history · 17
19 May 2025
PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8137438
28 March 2025
PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8099192
23 March 2025
PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8096833
13 March 2024
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7877855
18 July 2023
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7745829
18 March 2022
PSC A
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7414358
11 March 2022
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7414053
2 January 2022
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7374627
28 July 2021
Deficiency Check · PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7267103
22 July 2021
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7264129
19 July 2019
ISPS II Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6745959
20 June 2018
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6450275
22 November 2017
ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6311664
8 June 2017
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6154795
1 June 2017
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6162360
18 April 2017
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6127313
23 March 2016
PI Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5836819
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 23 March 2025
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Upon inspection of all life rafts, PSCO found banding straps still attached from delivery installed, preventing proper inflation. SOLAS (20) III/20.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 March 2025
Resolution: Rectified via LR Class report dated 3/24/2025 in Documents tab.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 March 2025
Resolved
Means shall be provided to control leaks of flammable liquids. PSCO identified excessive leaks on top and adjacent to the Primary Oily Water Tank, from the motor in the Elevator Machine Room, and from the oil filter on Generator #2. SOLAS (09) II-2/4.1.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 March 2025
Resolution: Rectified via LR Class report dated 3/24/2025 in Documents tab.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 March 2025
Resolved
Electrical installations shall be such that the safety of passengers, crew, and ship from electrical hazards will be ensured. PSCO identified open switchboard with unapproved ventilation source in Elevator Machine Room. SOLAS (04) II-1/40.1.3
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 March 2025
Resolution: Rectified via LR Class report dated 3/24/2025 in Documents tab.
12 - Dangerous Goods › N/A - No Subsystem › Personal protection
Issued 23 March 2025
Resolved
The machinery ... shall be so installed and protected to reduce to a minimum any danger to persons on board, due regard being paid to moving parts. PSCO identified Skimmer for floating oil in Primary Oily Water Tank not installed IAW manufacturer's design. SOLAS (04) II-1/26.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 March 2025
Resolution: Rectified via LR Class report dated 3/24/2025 in Documents tab.
08 - Alarms › N/A - No Subsystem › Steering gear alarm
Issued 23 March 2025
Resolved
A low-level alarm for each hydraulic fluid reservoir ... shall be given on navigation bridge. No alarm for low-level hydraulic fluid given on navigation bridge for pump #1. SOLAS (04) II-1/29.12.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 March 2025
Resolution: Rectified via LR Class report dated 3/24/2025 in Documents tab.
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 23 March 2025
Resolved
Every steam pipe and every fitting connected thereto through which steam may pass shall be so designed, constructed, and installed as to withstand the maximum working stress to which it may be subjected. PSCO identified steam leak on pipe IWO purifier room above Low Sulfur HFO Settling Tank. SOLAS (04) II-1/33.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 March 2025
Resolution: Rectified via LR Class report dated 3/24/2025 in Documents tab.
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 23 March 2025
Resolved
Machinery spaces of Category A shall be adequately ventilated so as to ensure that when machinery or boilers therein are operating at full power in all weather conditions including heavy weather, and adequate supply of air is maintained. PSCO identified that manual louvers not open during operation of EDG despite clear signage to leave open for ventilation.
Action required: 10 - Deficiency Rectified
Resolved 24 March 2025
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company verification, review and evaluation
Issued 23 March 2025
Resolved
The Company should establish procedures to ensure that the ship is maintained in conformity with the Provisions of the relevant rules and regulations. The above technical deficiencies, though of such a nature that do not warrant the detention of the ship, still indicate a failure or lack of effective implementation of the ISM Code related to onboard maintenance protocols. An internal audit of maintenance procedures is to be conducted and corrective actions implemented within three months from 24Feb2025 as required by Paris MoU Exam conducted in Hamburg, Germany. SOLAS (20) IX/3.1 ; ISM Code 10
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 19 May 2025
Resolution: Recieved the required audit report. See attached.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 28 July 2021
Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT CONVENTION TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT PRESENTING AN UNREASONABLE THREAT OF HARM TO THE MARINE ENVIRONMENT. PSCO NOTED DURING FUNCTION TEST OF THE EMERGENCY GENERATOR, VOLTAGE METER INDIACTED 320 VOLTS. PER MANUFACTURERS DATA PLATE, RUNNING VOLTAGE SHOULD BE 440 VOLTS.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 29 July 2021
Resolved 28 July 2021
Resolution: Witnessed operation of emergency generator in a simulated loaded condition. Generator output was found to be in good order with readings of 440 volts and 60 cycles.