POSEIDON VENTURE is a 2006 freight ship. The Coast Guard has recorded 8 inspections since 2016, most recently in January 2024, along with 1 deficiency and 1 operational control.
Records from 2016 to 2024. Most recent: operational control imposed, 11 January 2024.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it25754 - Convention (Subpart B), Net Ton 76585 - Dead Weight, Metric Ton 86824 - Displacement, Metric Ton 39738 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 8
11 January 2024PSC B · Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7842697
11 January 2024Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7848103
11 January 2024Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7852766
25 May 2022Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7459041
12 October 2021PSC B
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7323486
20 November 2017PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6304877
27 June 2017Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6188416
21 October 2016PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6018741
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 January 2024Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. PSCO observed a temporary, non-class approved, repair to the sea water inlet pipe of the L/O heat exchanger. 74 SOLAS AM, II-1/26, 60ac
Condition: Placed in Improper Service
Action required: 60 - Rectify deficiencies prior to movement
Due 11 January 2024
Resolved 12 January 2024
Resolution: Received, reviewed and accepted Class Report from CCS attesting to the permanenet repair to the sea water inlet pipe on the lube oil heat exchanger.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.