MAURY USCG vessel records Sign in
← All vessels

TANJA KOSAN

TANJA KOSAN is a 1999 tank ship. The Coast Guard has recorded 27 inspections since 2000, most recently in September 2019, along with 9 deficiencies and 11 operational controls.

Records from 2000 to 2019. Most recent: inspection, 20 September 2019.

Built
1999
Last inspected
20 September 2019
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9174361 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
ISLE OF MAN
—
Maury page id
psix-8478

Inspections, by type

…with no type recorded10
Years with a record 12 calendar years (2000–2019)
The 27 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it4693 - Convention (Subpart B), Gross Ton
1754 - Convention (Subpart B), Net Ton
9051 - Displacement, Ton
5996 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 27

20 September 2019 ISPS II Exam · COC-CHEM & TVE Renew · Ballast Water Examination
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 6811582
3 October 2018 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6554375
28 September 2018 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6550454
31 January 2018 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6347057
28 December 2017 COC-GAS Annual · Ballast Water Examination · ISPS II Exam · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6328636
26 December 2017 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6329168
9 October 2016 Deficiency Check
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 6019186
9 October 2016 Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 6033195
7 October 2016 COC-GAS Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 6018775
20 November 2015 Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5767237
10 February 2011 Damage Survey
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3943061
10 February 2011 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3946425
8 February 2011 Ballast Water Examination · ISPS II Exam · COC-GAS Renew
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3939557
21 March 2009 Ballast Water Examination · COC-GAS Renew · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3437517
24 October 2007 Ballast Water Examination · ISPS III Exam · COC-GAS Annual
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3086070
20 July 2007 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3001721
19 May 2007 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2934608
13 January 2007 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2855223
28 October 2006 COC-GAS Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2809758
14 July 2006 ISPS II Exam · COC-GAS Annual · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2712542
13 July 2006 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2711483
6 August 2005 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2460794
26 November 2004 COC-GAS Renew · ISPS II Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2248319
25 November 2004 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2248037
24 November 2004 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2254005
27 May 2000 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 278452
27 May 2000 Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1049532

Deficiency record · 9

Documentation › Certificates/Documents › Certificate of Fitness (GC Code)
Issued 28 December 2017 Resolved
Vessel's COF (list of products, 21NOV2017) lists maximum density of 614 kg/m3, but vessel is authorized several cargoes with a density greater than this (ex: vinyl chloride; ~972 kg/m3). (74 SOLAS 14 VII/13.1 REF IGC 93/1.5.4) (50ac)
Action required: 705 - Other - as specified
Due 28 January 2018
Resolved 31 January 2018
Resolution: Received updated COF that authorizes carriage of products with higher density at lower MARV setting (4.3 bar) and/or filling limit. Company provided documentary evidence to show the carriage of butadeine at incorrect MARV setting did not overstress tank.
Electrical › Lighting (service) › Lighting Fixture
Issued 28 December 2017 Resolved
Electrical equipment should not be installed in hazardous locations unless it conforms with the standards not inferior to those acceptable to the Administration [IEC 60092:502]. Explosion-proof light in compressor room area (i.e. under forecastle) found with dried salt inside light; seal is no longer good. (74 SOLAS 14 VII/13.1 REF IGC 93/10.1.4) (10c)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 December 2017
Resolved 28 December 2017
Resolution: Crew presented spare explosion-proof light fixture to attending PSCOs prior to completion of exam.
Engineering › Shafting/Propeller Arrangements › Propeller (controllable pitch)
Issued 9 October 2016 Resolved
1499-Other(Prop. an AUX. Machinery)- Means shall be provided whereby normal operations of propulsion machinery can be sustained or restored even though one of the essential auxiliaries becomes inoperative. Normal operation of propulsion machinery cannot be sustained due to the malfunction of the vessel's controllable-pitch proellor. SOLAS 74(09 Cons.),CH.II-1/26.3.10.
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 October 2016
Resolution: Received a Class report confirming the proper operational condition of the controllable pitch propeller.
Engineering › Diesel Engine (propulsion-direct drive) › Valve
Issued 10 February 2011 Resolved
Vessel lost propulsion due to exhaust valve lube oil booster pump pressure was low.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 February 2011
Resolution: Received class report attesting to satisfactory repair of propulsion system.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Closure Devices
Issued 28 October 2006 Resolved
Cargo tank #1 loading line quick closing valve failed to close upon activation of overfill alarm IGC 13.3.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 October 2006
Resolution: Received class report stating the valve closing sensor was adjusted by a technician from Radio Holland. The valve closing was tested upon activation of the overfill alarm
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pressure/Vacuum Relief Valve
Issued 28 October 2006 Resolved
Ship's personnel were unable to demonstrate cargo tank high pressure alarms IGC 13.4.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 October 2006
Resolution: Received class report stating the cargo tank high pressure alarms tested at 3.9 bars.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 28 October 2006 Resolved
Port side eyewash station has insufficient pressure to wash a person's eyes. I.G.C. 14.4.3
Action required: 705 - Other - as specified
Resolved 28 October 2006
Resolution: Deficiency rectified on the spot in the presents of Coast Guard
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pressure/Vacuum Relief Valve
Issued 28 October 2006 Resolved
The tag on the safety relief valve, with serial number X972318, on cargo tank number one, verifying the relief valve has been set and sealed by a competent authority acceptable to the Administration is no longer affixed to the relief valve. I.G.C. 8.2.5
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 October 2006
Resolution: Class provided a report of survey stating the valve was removed from the vessel, taken to the facilities of Puffer Sweiven in La Porte, tested to 4.3 bars and sealed. Testing and sealing was witnessed by the surveyor.
Electrical
Issued 27 May 2000 Resolved
Provide class report attesting to the proper operation of the emergency generator.
Condition: Unknown
Due 28 May 2000
Resolved 5 June 2000

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.