Records from 2006 to 2026. Most recent: inspection, 2 February 2026.
Inspection history · 38
2 February 2026
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8305087
30 December 2025
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8288369
10 December 2025
PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8278725
23 October 2025
Deficiency Check · PSC B
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8257672
20 October 2025
Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8255413
24 October 2020
Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7083387
30 August 2020
Type not recorded
No type recorded · Station Alexandria Bay · USCG Great Lakes District (CGD-GL) · Activity 7046409
28 August 2020
PSC B
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7044625
28 August 2020
COE-Administrative
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7044879
27 August 2020
Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7043810
23 July 2019
Administrative Inspection · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6759253
11 July 2019
ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6745632
16 November 2018
Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 6581950
26 June 2018
ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6456281
5 June 2017
PII Safety Exam · COE-Dockside · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6165953
19 December 2016
ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6059551
16 September 2016
COE-Dockside
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6002307
10 July 2016
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5929048
8 January 2016
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 5794191
26 October 2015
Deficiency Check · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5750605
5 July 2012
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4368133
15 June 2012
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4348227
15 December 2011
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4208652
12 December 2011
PII Safety Exam · Administrative Inspection · Ballast Water Examination · ISPS I Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4206307
13 December 2010
COE-Offshore · PII Safety Exam · Ballast Water Examination · Deficiency Check · ISPS II Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3908120
13 December 2010
Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3909549
12 December 2010
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3908427
25 January 2010
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3669860
2 April 2009
NPV Safety Exam · ISPS III Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3444159
26 October 2008
PII Safety Exam · ISPS II Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 3351621
3 March 2008
ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3157694
2 June 2007
Random ISPS/MTSA/PSC
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2949293
1 June 2007
Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2948700
16 October 2006
MARPOL Annex V Examination · PII Safety Exam · ISPS III Exam · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2800889
6 October 2006
Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2795349
27 August 2006
MARPOL Annex I Examination · ISPS II Exam · PII Safety Exam · Ballast Water Examination · MARPOL Annex V Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2761126
25 August 2006
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2760135
19 August 2006
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2753188
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 October 2025
Resolved
13101 The machinery, boilers, and other pressure vessels, assosiated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum, any danger to persons on board. Main engine was found with multiple jacket water leaks.
74 SOLAS 04 II-1/26.1
17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 26 October 2025
Resolved 26 October 2025
Resolution: Vessel submitted statisfactory class report attesting to the correction of all jacket water leaks.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 23 October 2025
Resolved
07126 The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. for this purpose, the following functional requirements shall be met: means shall be provided to control leaks of flammable liquids. Pooled oil was found throughout the engine space to include main engine, generators, purifiers, and steering gear.
74 SOLAS 25 II-2/4.1.1
17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 26 October 2025
Resolved 26 October 2025
Resolution: Vessel submitted statisfactory class report attesting to the correction of all oil leaks.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 23 October 2025
Resolved
The provision of safe means of acces to and throughout the ship, and the satisfactory physical condition of ladders, decks, bulwarks, fencing, handrails, ect.Through holes on deck plates in engine room were found missing.
ILO-C 147/ PWSA 46 USC CHAPTER 700, SECTION 70002 PG 45
16ac
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 November 2025
Resolved 26 October 2025
Resolution: All through holes have been covered with the appropriate sized deck plate.
Operations/Management › Pollution › Changeover Not Completed Prior to ECA
Issued 19 December 2016
Resolved
While ships are operationg within an ECA, the sulfur content of fuel shall not exceed .1%. The PSCO discovered the vessel operatedin the North American ECA using fuel that does not comply with MARPOL annex VI on 16DEC2016. MARPOL annex VI Reg 14.4
Condition: Invalid
Action required: 705 - Other - as specified
Due 19 December 2016
Resolved 19 December 2016
Resolution: corrected on spot
Lifesaving › Lifeboat Equipment › Hand Flare
Issued 13 December 2010
Resolved
Life Boat hand flares are expired. Life Boat is required to have six hand flares that are operational ready. replace hand flares in accordance with manufacturer recommended timeline. SOLAS (2009 cons) III/20.2 LSA code 4.4.8.14 17c
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 December 2010
Resolution: Hand flares were delivered to boat. Reciept attached.
Engineering › Freshwater Generation System › Piping
Issued 13 December 2010
Resolved
The fresh water generator is holed and has been temporarily repaired with a soft patch. Class to attest to proper repairs. SOLAS (2009 cons) I/11 70a
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 15 December 2010
Resolution: Hole was repaired to the satisfaction of class. Report attached.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 13 December 2010
Resolved
The Oily Water Separator piping to the three way valve at the OWS is holed. vessel placed a non-approved soft patch repair on the pipe. Class to attest to proper repairs. SOLAS (2009 cons) I/11 17a
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 December 2010
Resolution: Hole was repaired to the satisfaction of Class. Class report attached.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 2 April 2009
Resolved
SPAN GAS FOR PORTABLE GAS DETECTORS IS NOT ONBOARD. FOR PROPER CALIBRATION IN ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS, SPAN GAS MUST BE USED.
SOLAS 04 CH VI/1.2 BC CODE 7.6.1
Action required: 705 - Other - as specified
Due 2 May 2009
Resolved 25 January 2010
Lifesaving › Inflatable Liferafts › Inflation Characteristics
Issued 1 April 2009
Resolved
6-MAN FORWARD LIFERAFT WAS DAMAGED DURING ROUGH WEATHER IN TRANSIT MAKING IT INOPERABLE.
SOLAS 04 CH III/31.1.4
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 April 2009
Resolution: New 6 man life raft delivered to the vessel and stowed correctly.
Fire Fighting › Emergency Fire Pumps › Pressure
Issued 1 April 2009
Resolved
EMERGENCY FIRE PUMP MOTOR DAMAGED WHEN WATER INTRUDED INTO BOW THRUSTER SPACE MAKING IT INOPERABLE.
SOLAS CH II-2/10.2.2.3.1.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 April 2009
Resolution: Emergency fire pump motor has been cleaned and repaired. Tested satisfactorily in the presence of the class surveyor.
Construction/Loadline › Structures › Machinery Space Opening
Issued 1 April 2009
Resolved
BOW THRUSTER SPACE HAD WATER INTRUSION UP TO APPROX. 01 METER. SPACE HAS BEEN DEWATERED AND NO FURTHER WATER INTRUSION DETECTED. FOR SAFETY OF CREW AND ASSURED PREVENTION OF FLOODING. INDENTIFY SOURCE OF INTRUSION AND REPAIR.
SOLAS 04 CH II-1/3.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 April 2009
Resolution: Received class report clearing above deficiency.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 1 April 2009
Resolved
EMERGENCY LIGHTING FOR BOW MUSTER STATION IS BROKEN AND FILLED WITH WATER MAKING MUSTER STATION UNLIT DURING EMERGENCY EVACUATION.
SOLAS 04 CH II-1/43.2.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 April 2009
Resolution: Emergency lighting for bow muster station has been repaired.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 27 August 2006
Resolved
The Oily Water Separator oil content meter and alarms are not operating properly. Prove proper operation of the content meter and alarms.
Action required: 705 - Other - as specified
Due 3 September 2006
Resolved 6 October 2006
Resolution: Class Survey received at MSU Lake Charles.
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 27 August 2006
Resolved
The incinerator is not operating as designed and would not start. Prove proper operation of the incinerator.
Action required: 705 - Other - as specified
Due 3 September 2006
Resolved 6 October 2006
Resolution: Class Survey received at MSU Lake Charles.
Engineering › Generator (propulsion/auxiliary-electric) › Junction Box
Issued 27 August 2006
Resolved
The No. 2 and No. 3 generator injection box drains are not draining properly and leaking oil along the side of the generator in the vicinity of the flywheel. Clean drains and wipe down excessive oil on the side of the generator.
Action required: 705 - Other - as specified
Due 3 September 2006
Resolved 6 October 2006
Resolution: Class Survey received at MSU Lake Charles.