Records from 1994 to 2026. Most recent: inspection, 16 July 2026.
Documentation record
Registered dimensions (L × B × D)51.5 ft × 20.0 ft × 6.7 ft
Registered tonnagegross 61 / net 41
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderUNIVERSAL IRON WORKS INC LA · HOUMA, LA, UNITED STATES · built 1964
Hull materialSteel
PropulsionDiesel
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 17 November 2025 · expires 30 November 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it41 - Regulatory (Subpart C or D), Net Ton
41 - Dead Weight, Ton
61 - Displacement, Ton
61 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 19
16 July 2026
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8439367
29 April 2025
COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8117867
15 April 2025
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8109698
28 October 2024
Internal Structural Exam · Administrative Inspection · Deficiency Check · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8025875
9 April 2024
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7892864
9 March 2023
Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7648223
16 November 2021
COI Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7352528
21 July 2021
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7263637
28 November 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6588153
20 November 2018
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6584471
13 November 2014
Type not recorded
No type recorded · Station New York · USCG Northeast District (CGD-NE) · Activity 5023266
9 March 2012
Industry Initiated Exam · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4262787
14 February 2012
Administration
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4244334
5 April 2010
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3709346
22 December 2006
MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2845039
4 May 2006
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2640392
23 July 2004
Type not recorded
No type recorded · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2142913
9 June 2004
Type not recorded
No type recorded · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2142694
3 March 1994
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 226902
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 July 2026
Resolved
Each towing vessel must have either a self-priming, power-driven, fixed fire pump, a fire main, and hoses and nozzles in accordance with paragraphs (a) through (d) of this section; or a portable pump, and hoses and nozzles, in accordance with paragraphs (e) and (f) of this section. Vessel unable to exceed 20 psi at pump at time of the inspection. Prior to movement, vessel must meet requirement per 142.325(a)(1) for pump pressure and flow rate to the satisfaction of attending Marine Inspector.
46 CFR 142.325
Action required: 60 - Rectify deficiencies prior to movement
Resolved 6 August 2026
Resolution: Satisfactorily tested installed fire pump on board. Held Fire pump at over 50 psi for multiple minutes.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 July 2026
Resolved
For towing vessels with berthing aboard, a sufficient number of additional lifejackets must be carried so that a lifejacket is immediately available for persons at each normally manned watch station. Vessel added additional required lifejacket to flybridge.
46 CFR 141.340(b)
Action required: 10 - Deficiency Rectified
Resolved 16 July 2026
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 29 April 2025
Resolved
vessel missing 03 line throwing appliances
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2025
Resolved 16 July 2026
Resolution: Vessel had required linethrowing appliances on board at time of inspection.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 29 April 2025
Resolved
New EPIRB was not registered
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2025
Resolved 16 July 2026
Resolution: Vessel provided valid EPIRB registration at time of inspection.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 28 October 2024
Resolved
A towing vessel may not be operated without having onboard a valid COI issued by the Coast Guard as required by § 136.202. Vessel missed their annual inspection and is required to cease all operations until the vessel receives a new COI.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2025
Resolved 1 May 2025
Resolution: Vessel received 5 year COI
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 9 March 2023
Resolved
A towing vessel may not be operated without having onboard a valid COI issued by the Coast Guard as required by § 136.202. The Vessel missed their annual inspection and is required to cease all operations until the vessel is certificated under the provisions of its required sub-chapter.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 April 2023
Resolved 26 April 2023
Resolution: recieved new COI
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 9 March 2023
Resolved
"Each towing vessel must have a fire-detection system installed to detect engine room fires. The owner or managing operator must ensure...the system is installed, tested, and maintained in accordance with the manufacturer's design manual." The fire detection system was not operating properly and detection in the engine room could not alarm.
Action required: 60 - Rectify deficiencies prior to movement
Due 27 April 2023
Resolved 27 April 2023
Resolution: Witnessed operable fire alarm operation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 March 2023
Resolved
"There must be an installed or portable bilge pump for emergency dewatering. Any portable pump must have sufficient hose length and pumping capability." Fixed bilge system pumping at a slow rate. portable pump does not have sufficient hose length.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 May 2023
Resolved 1 June 2023
Resolution: fixed bigle pump was repaired
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 9 March 2023
Resolved
"A fixed fire pump must be capable of: (1) Delivering water...(at) a flow rate of at least 300 liters per minute" Fixed fire pump would not meet the flow rate requirements.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 May 2023
Resolved 1 June 2023
Resolution: fixed fire pump repaired
01 - Certificates & Documentation › 012 - Crew Certificates › Evidence of Basic Training
Issued 9 March 2023
Resolved
"Safety orientations and other crew training must be documented in the TVR, official logbook, or in accordance with the TSMS applicable to the vessel. The entry must include: (1) The date of the safety orientation or training; (2) A general description of the safety orientation or training topics; (3) The name(s) and signature(s) of individual(s) providing the orientation or training; and (4) The name(s) of the individual(s) receiving the safety orientation or training." Vessel had no record of crew training or safety orientation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 May 2023
Resolved 27 April 2023
08 - Alarms › N/A - No Subsystem › Engineers' alarm
Issued 9 March 2023
Resolved
"Alarms must: (1) Be visible and audible at each operating station" engine alarm at main operating station was not labeled.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 May 2023
Resolved 27 April 2023
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 9 March 2023
Resolved
"Alarms must: (1) Be visible and audible at each operating station" upper wheel house alarms were not functional.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 May 2023
Resolved 24 May 2023
Resolution: Recieved documentation to clear def.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 March 2023
Resolved
"Each lifebuoy on a towing vessel must: (1) Be approved under approval series 160.050 or 160.150" Ring Buoys not stenciled and grab lines are weathered and frayed. One buoy should be without a line.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 May 2023
Resolved 27 April 2023
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 March 2023
Resolved
"Chemical testing of personnel must be conducted as
required by this subpart and in accordance with the
procedures detailed in 49 CFR part 40" Chemical testing is currently being conducted by a lab that does not have HHS certification.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 May 2023
Resolved 1 June 2023
Resolution: recieved proof of enrollment in DAPI
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 March 2023
Resolved
"Pressure vessels over 5 cubic feet in volume and over 15 pounds per square inch maximum allowable working pressure (MAWP) must be equipped with an indicating pressure gauge (in a readily visible location) and with one or more spring-loaded relief valves. The total relieving capacity of such relief valves must prevent pressure from exceeding the MAWP, as established by the manufacturer, by more than 10 percent" Air compressor in the engine room did not have the setpoint stenciled on the relief valve. MAWP must be indicated.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 May 2023
Resolved 23 May 2023
Resolution: Recieved pictures and invoice of new relief valve installed and corrected tank markings.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 March 2023
Resolved
"Each wire and cable run must be installed in a manner to prevent contact with personnel, mechanical hazards, and leaking fluids. Wire and cable runs must not be installed in bilges, across a normal walking path, or less than 24 inches from the path of movable machinery" wiring found to be zip tied to remote fuel shut off. Wiring must be installed in a way that minimizes hazards.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 May 2023
Resolved 27 April 2023
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 28 November 2018
Resolved
Vsl is not broadcasting static draft information and Vsl is not broadcasting an AIS Ship Type
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 4 December 2018
Resolution: Errors were corrected.