MAURY USCG vessel records
← All vessels

INDUSTRIAL DIAMOND

INDUSTRIAL DIAMOND is a 2006 freight ship. The Coast Guard has recorded 16 inspections since 2017, most recently in May 2026, along with 7 deficiencies and 3 operational controls.

Records from 2017 to 2026. Most recent: inspection, 18 May 2026.

Built
2006
Last inspected
18 May 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 18 May 2026
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 7 calendar years (2017–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9347827
850556
Flag
ANTIGUA AND BARBUDA
Maury page id
psix-850556

Documentation record

Tonnage as PSIX records it7223 - Convention (Subpart B), Gross Ton
2918 - Convention (Subpart B), Net Ton
12372 - Displacement, Ton
8034 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 16

18 May 2026 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8375542
18 May 2026 Explosive Handling Operation-Commercial
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8377355
6 January 2026 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8290726
19 October 2025 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8255129
30 August 2025 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8220834
15 March 2025 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8094221
26 February 2025 Deficiency Check · Administrative Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 8084821
8 October 2024 PSC B · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8015835
2 May 2022 PSC B · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7442132
19 August 2021 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7291056
27 March 2021 PSC B
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7161289
23 March 2021 Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7161515
24 July 2019 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6760595
15 July 2019 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6751032
7 November 2017 Ballast Water Examination · Deficiency Check · ISPS II Exam · PII Safety Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6298895
7 November 2017 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6302481

Deficiency record · 7

07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 8 October 2024 Resolved
74SOLAS(2009ED) II-2/4.1.1 17ac Means shall be provided to control leaks/ignition of flammable liquids. PSCO observed active leaking from outboard generator from fuel pressure sensor.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 October 2024
Resolved 8 October 2024
Resolution: PSCO received satisfactory class report.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 October 2024 Resolved
74SOLAS(2009ED) II-2/4.1.5 50ac Ignition sources shall be seperated from combustible materials and flammable liquids. PSCO observed cover missing from explosion-proof lighting fixture in paint locker. Spares not readily available.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2024
Resolved 26 February 2025
Resolution: Vessel sent photo of explosion proof lighting installed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 8 October 2024 Resolved
74SOLAS(2004ED) II-1/40.1.3 50ac Electrical installations shall be such that the safety of crew from electrical hazards will be ensured. PSCO observed headset near marine sanitation device with frayed wiring spares not readily available.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2024
Resolved 26 February 2025
Resolution: Vessel sent photo of corrected wiring.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 2 May 2022 Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company[ISM 10.1]. In meeting these requirements the company should ensure that inspections are held at appropriate intervals[ISM 10.2.1] and any non-conformity is reported, with its possible cause, if known[ISM 10.2.2]. Ships on board maintenance manual[2M-0701] states fire detection systems are to be tested for proper operation monthly[FSS 4.2.2]. Ships SMS maintenance [Form 5.2.6] gives guidance for testing fire detection systems according to makers instructions which should be kept on boar. As delineated in deficiency #2 the ship failed to follow ships procedures for conducting routine inspections of the fire detection system[ISM 10.2.1] and making repairs of non-conformities. PSCO observed three smoke detectors in engine room (one in generator room)(two forward of the engine room) being held up by tape. Crew has not been testing heat/flame detectors and is unfamiliar with testing procedures. Ship does not have testing procedures or equipment. An internal audit of the ships SMS focusing on the testing of fire detection systems is required.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 July 2022
Resolved 26 February 2025
Resolution: Received SMS audit from class stating no non-conformaties and that monthly testing was now taking place.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 2 May 2022 Resolved
Maintenance, testing and inspections shall be carried out based on the guidelines developed by the organization to ensure the reliability of fire-fighting systems and appliances. PSCO observed crew is not conducting monthly inspections and testing of the flame detectors on board the ship as required by their SMS maintenance procedures.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 February 2025
Resolution: Receieved SMS audit from class stating no non-conformaties and that monthly testing was now taking place.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 2 May 2022 Resolved
Fire protection systems shall be kept in good order so as to ensure their performance. Fire detection and fire alarm systems. PSCO observed crew was not able to test flame detectors in the engine room and cannot confirm their performance.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 February 2025
Resolution: Received SMS audit from class stating no non-conformaties and that monthly testing was now taking place as required.
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 27 March 2021 Resolved
07111 - Fire Fighter's outfits shall comply with the fire systems code. Personal equipment shall consist of the following: Protective clothing of material to protect the skin from heat radiating from the fire and from burns and scalding by steam. The outer surface shall be water risistant. The PSCO found that both fire figher's outfits' foil was peeling. SOLAS 74 (14) II-2/10.1.1 FSS Code 2.1.1.1 10c.
Action required: 10 - Deficiency Rectified
Resolved 27 March 2021
Resolution: Ship was able to procure two new Fire Suits.

Ownership record