Records from 2007 to 2024. Most recent: inspection, 30 January 2024.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 9 July 2007
Resolved
All officers missing endorsements from flag. (Sierra Leone)
Action required: 705 - Other - as specified
Due 30 January 2024
Resolved 30 January 2024
Resolution: 30JAN2024: Due to age of open deficiencies, I have cleared them to clean up Sector Miami Open Deficiencies List. No activities since 2007.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 9 July 2007
Resolved
Vsl's fire control plans on port and starboard side were wet and unreadable.
Action required: 705 - Other - as specified
Due 30 January 2024
Resolved 30 January 2024
Resolution: 30JAN2024: Due to age of open deficiencies, I have cleared them to clean up Sector Miami Open Deficiencies List. No activities since 2007.
Accommodation/Occupational Safety › Messroom › Location
Issued 5 July 2007
Resolved
Live chickens improperly stowed in crew mess.
Action required: 17 - Rectify deficiencies prior to departure
Due 5 July 2007
Resolved 9 July 2007
Resolution: Chckens removed from vsl.
Navigation › Emergency Steering › Communications to Emergency Steering
Issued 5 July 2007
Resolved
Improperly stowed cargo prevents use of emergency steering arrangement
Action required: 17 - Rectify deficiencies prior to departure
Due 5 July 2007
Resolved 9 July 2007
Resolution: Cargo removed.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 5 July 2007
Resolved
Unsecured materials in steering room present hazard to proper function of steering gear.
Action required: 17 - Rectify deficiencies prior to departure
Due 5 July 2007
Resolved 9 July 2007
Resolution: Materials removed from steering room.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 5 July 2007
Resolved
Ship missing gangway/brow.
Action required: 17 - Rectify deficiencies prior to departure
Due 5 July 2007
Resolved 9 July 2007
Resolution: Ship is now accessible by gangway.
Navigation › Emergency Steering › Communications to Emergency Steering
Issued 5 July 2007
Resolved
Hand radios essential for intra-ship communication inoperable.
Action required: 17 - Rectify deficiencies prior to departure
Due 5 July 2007
Resolved 9 July 2007
Resolution: Hand radio''s worked during drills and all tests.
Engineering › Steering Gear System › Power Unit
Issued 2 June 2007
Resolved
Vessel's steering systems appears to be under powered while cargo is present onboard. Ensure that steering system operates in accordance with the applicable CCSSC standards.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 July 2007
Resolution: Steering system tested satisfactory.
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 2 June 2007
Resolved
Vessel doesn't have a working toilet onboard.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 July 2007
Resolution: Vsl now has working toilet onboard.
Deck/Cargo › Cargo Stowage › General
Issued 2 June 2007
Resolved
Vessel has cargo blocking the entrance to the emergency steering gear compartment.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 July 2007
Resolution: Cargo has been removed.
Deck/Cargo › Cargo Stowage › General
Issued 2 June 2007
Resolved
Hazardous cargo stored on vessel improperly segregated.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 July 2007
Resolution: Hazardous cargo has been removed.
Deck/Cargo › Cargo Stowage › General
Issued 2 June 2007
Resolved
Cargo stored in accommodation spaces.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 July 2007
Resolution: Cargo has been removed.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 2 June 2007
Resolved
GENERAL: Vessel has numerous electrical fixtures throughout the ship that are improperly wired and/or have improperly spliced wires.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 July 2007
Resolution: Vsl has removed loose electrical wiring and extension cords.
Pollution Prevention/Response › Prevention Equipment › Oily Residue (sludge/slop) Tank
Issued 4 April 2007
Resolved
Remove bilge oil from drums in cargo space.
Action required: 705 - Other - as specified
Due 4 April 2007
Resolved 3 May 2007
Fire Fighting › Portable CO2 Fire Extinguisher › Approval
Issued 4 April 2007
Resolved
Provide approved fire plan for vessel
Action required: 705 - Other - as specified
Due 4 April 2007
Resolved 3 May 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 4 April 2007
Resolved
Properly wire galley fridge (hardwire)
Action required: 705 - Other - as specified
Due 4 April 2007
Resolved 3 May 2007
Electrical › Electrical Distribution System (service) › Junction Box
Issued 4 April 2007
Resolved
Galley junction box missing protective cover
Action required: 705 - Other - as specified
Due 4 April 2007
Resolved 3 May 2007
Fire Fighting › Firemans Outfit › Self-Contained Breathing Apparatus
Issued 4 April 2007
Resolved
Refill all firefighting outfit SCBA bottles
Action required: 705 - Other - as specified
Due 4 April 2007
Resolved 3 May 2007
Stability › Incline Test › General
Issued 4 April 2007
Resolved
Provide approved stability manual for vessel.
Action required: 705 - Other - as specified
Due 4 April 2007
Resolved 3 May 2007
Construction/Loadline › Structures › Superstructure
Issued 4 April 2007
Resolved
Provide administration approval for pilot house windows
Action required: 705 - Other - as specified
Due 4 April 2007
Resolved 3 May 2007