Records from 2006 to 2025. Most recent: inspection, 1 July 2025.
Documentation record
Registered dimensions (L × B × D)55.0 ft × 22.0 ft × 8.0 ft
Registered tonnagegross 64 / net 51
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderVERRET SHIPYARD INC · PLAQUEMINE, LA, UNITED STATES · built 2006
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portLOUISIANA, MO
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 11 September 2025 · expires 31 October 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it64 - Simplified, Gross Ton
51 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 14
1 July 2025
Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8160148
16 May 2024
Administrative Inspection · COI Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7900823
26 March 2024
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7884621
22 February 2023
Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7639631
12 April 2022
Annual Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7409781
24 February 2021
COI Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7146174
1 January 2021
Administrative Inspection
Administrative · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7154216
3 April 2019
Administrative Inspection · DAPI Audit · Deficiency Check · Initial Certification
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6656512
21 March 2013
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4553986
23 July 2012
Type not recorded
No type recorded · Suspension & Revocation National Center of Expertise · Activity 4404749
25 April 2012
DAPI Audit
Administrative · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 4298780
25 April 2012
Deficiency Check · Industry Initiated Exam
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4299710
10 August 2010
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3820331
26 September 2006
In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2787100
07 - Fire Safety › N/A - No Subsystem › Crew alarm
Issued 12 April 2022
Resolved
Each towing vessel must be equipped with a means to detect smoke in berthing spaces and lounges. The berthing areas were missing smoke alarms. Install smoke alarms meeting UL 217 to all berthing areas.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2022
Resolved 21 April 2022
Resolution: The deficiency was cleared to the satisfaction of an USCG Marine Inspector.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 24 February 2021
Resolved
Ensure cres are recording all required preunderway and nav assesment items required in TVR
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 March 2021
Resolution: Conducted training and provided evidence of log entries
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 24 February 2021
Resolved
Remove all excess oil and deberis from the engine room bilges.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 March 2021
Resolution: Cleaned bilges
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 24 February 2021
Resolved
Any surfaces over 220 degrees must be covered to prevent accidental contact with crew or combustable materials.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 March 2021
Resolved 23 March 2021
Resolution: Vessel properly insulated exhaust system
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 February 2021
Resolved
Battery boxes must be secured to prevent shifting while underway.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 March 2021
Resolved 2 March 2021
09 - Working and Living Conditions › 092 - Working Conditions › Personal equipment
Issued 24 February 2021
Resolved
Vessel must have unexpired first aid kit on board.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 March 2021
Resolved 2 March 2021
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 24 February 2021
Resolved
Vessel must provide egress lighting or photo luminescnet tape in all crew spaces.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 March 2021
Resolved 23 March 2021
Resolution: Vessel installed 120 minute emergency egress lighting.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 13 June 2019
Resolved
Ensure the MDE's and SSG's safety set points and the air receiver relief valve are properly tested.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 September 2019
Resolved 9 January 2020
Resolution: Witnessed satisfactory test of MDE and SSG safeties. See narrative for additional details.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 June 2019
Resolved
Insulate all exposed generator exhaust piping in excess of 428*
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 July 2019
Resolved 16 August 2019
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 June 2019
Resolved
Remove all flammable and combustibles from the engine room or install a U/L approved flammable locker
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 July 2019
Resolved 16 August 2019
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 13 June 2019
Resolved
Install egress marking or lights from all berthing and galley areas.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 July 2019
Resolved 16 August 2019
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 13 June 2019
Resolved
Verify the installed MSD is CG approved and instructions are present or replace the system with an approved one.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 July 2019
Resolved 16 August 2019
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 13 June 2019
Resolved
Develope and post a WQSB
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 July 2019
Resolved 16 August 2019
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 13 June 2019
Resolved
Ensure all engine room vents can be properly closed/sealed
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 July 2019
Resolved 16 August 2019
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 13 June 2019
Resolved
Ensure second deck lifering float light operates properly.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 July 2019
Resolved 16 August 2019