MAURY USCG vessel records
← All vessels

JODY RAY

JODY RAY is a 1964 passenger vessel (inspected). The Coast Guard has recorded 6 inspections since 2016, most recently in May 2017, along with 23 deficiencies, 1 operational control and 2 casualty investigations between 2012 and 2013.

Records from 2012 to 2017. Most recent: inspection, 31 May 2017.

Built
1964
Last inspected
31 May 2017
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls, the casualty record and the documentation record — is Professional, $39 a month. Sign in.

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 31 May 2017
Operational controls None recorded without a removal date
Years with a record 2 calendar years (2016–2017)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

7307366
WDD3802
Flag
UNITED STATES
Maury page id
psix-85290

Documentation record

Tonnage as PSIX records it66 - Regulatory (Subpart C or D), Net Ton
97 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

6 inspections, each with its date, unit and type; 23 deficiencies with the resolution recorded against each; 1 operational control with the dates imposed and removed; 2 casualty investigations, with date and classification; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 6

31 May 2017 Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6161693
11 May 2017 Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6146916
1 May 2017 Internal Structural Exam · COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6136137
13 March 2017 In-Service Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6104154
11 October 2016 Drydock Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6020249
17 March 2016 Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5834722

Deficiency record · 23

Communications › Public Address System › Loudspeaker
Issued 1 May 2017 Resolved
Currently no PA system installed.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 June 2017
Resolved 31 May 2017
Resolution: Witnessed sat operation of vsl P/A system.
Engineering › Bilge Water Management System › Strainer
Issued 1 May 2017 Resolved
Fore peak bilge system piping missing required strainer that is 3x the area opening.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 May 2017
Resolved 31 May 2017
Resolution: Verified new fwd peak bilge suction foot was installed and tested sat.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 1 May 2017 Resolved
Incorrect call sign
Condition: Invalid
Action required: 705 - Other - as specified
Due 14 May 2017
Resolved 11 May 2017
Resolution: Documents have been updated with correct call sign.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 1 May 2017 Resolved
Engine room lighting insufficient, lighting to dim.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 May 2017
Resolved 11 May 2017
Resolution: Battery has been replaced.
Engineering › Freshwater System (jacketwater cooling) › Storage Tank
Issued 13 March 2017 Resolved
STBD ship service generator J/W holding tank was corroded at the bottom and was actively leaking while the engine was running.
Action required: 705 - Other - as specified
Due 13 April 2017
Resolved 1 May 2017
Resolution: COI was revoked on 20APR2017, issued new COI on this date.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 13 March 2017 Resolved
FCC Safety Radio Certificate was expired
Action required: 705 - Other - as specified
Due 13 April 2017
Resolved 1 May 2017
Resolution: COI was revoked on 20APR2017, issued new COI on this date.
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 13 March 2017 Resolved
Bridge to Bridge Certificate was expired
Action required: 705 - Other - as specified
Due 13 April 2017
Resolved 1 May 2017
Resolution: COI was revoked on 20APR2017, issued new COI on this date.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 13 March 2017 Resolved
STBD fwd E/R bulkhead, had a weld seam crack.
Action required: 705 - Other - as specified
Due 13 April 2017
Resolved 1 May 2017
Resolution: COI was revoked on 20APR2017, issued new COI on this date.
Engineering › Fuel Oil Service System › Piping
Issued 13 March 2017 Resolved
F/O fill piping STBD side requires new clamps around the rubber hose portion. Port side fuel vent piping requires grounding cable.
Action required: 705 - Other - as specified
Due 13 April 2017
Resolved 1 May 2017
Resolution: COI was revoked on 20APR2017, issued new COI on this date.
Engineering › Fuel Oil Service System › Valve, Control
Issued 13 March 2017 Resolved
STBD reach rod for the fuel shutoff was broken on the deck, requires it to be re-welded
Action required: 705 - Other - as specified
Due 13 April 2017
Resolved 1 May 2017
Resolution: COI was revoked on 20APR2017, issued new COI on this date.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 13 March 2017 Resolved
Sewage type III, no holding tank, piping ovbd was open while in port
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 April 2017
Resolved 1 May 2017
Resolution: COI was revoked on 20APR2017, issued new COI on this date.
Electrical › Electrical Distribution System (service) › Cable
Issued 13 March 2017 Resolved
Multiple dead end wiring through out the vessel, require removal or proper termination.
Action required: 705 - Other - as specified
Due 13 April 2017
Resolved 1 May 2017
Resolution: COI was revoked on 20APR2017, issued new COI on this date.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 13 March 2017 Resolved
Emergency escape in galley needs to be determined of its adequacy as an escape.
Action required: 705 - Other - as specified
Due 13 April 2017
Resolved 1 May 2017
Resolution: COI was revoked on 20APR2017, issued new COI on this date.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 13 March 2017 Resolved
Crew state room in front of the E/R had loose and broken decking underneath the emergency escape ladder.
Action required: 705 - Other - as specified
Due 13 April 2017
Resolved 1 May 2017
Resolution: COI was revoked on 20APR2017, issued new COI on this date.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 13 March 2017 Resolved
Crew state room fwd port side requires cleaning, door entrance was hanging by one hinge, Emergency lighting was not mounted, Emergency escape requires the hinge door to open in the direction of escaping.
Action required: 705 - Other - as specified
Due 13 April 2017
Resolved 1 May 2017
Resolution: COI was revoked on 20APR2017, issued new COI on this date.
Engineering › Diesel Engine (propulsion-direct drive) › Block
Issued 13 March 2017 Resolved
Port MDE was overheating during normal running conditions. Cause is unknown. VSL owner is replacing with rebuilt (in kind) engine. Prove proper operation before placing vessel back in service.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 April 2017
Resolved 1 May 2017
Resolution: COI was revoked on 20APR2017, issued new COI on this date.
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 17 March 2016 Resolved
Master did not have an FCC Radio Permit as per 47 CFR 80.159.
Action required: 705 - Other - as specified
Due 17 April 2016
Resolved 19 April 2016
Resolution: Master provided proof of completion and application for FCC Marine Radio operators permit via Email to Marine Inspectors.
Documentation › Markings/Placards › Garbage Placard
Issued 17 March 2016 Resolved
Out of date MARPOL V Placard not IAW 33 CFR 151.59.
Action required: 705 - Other - as specified
Due 17 April 2016
Resolved 17 April 2016
Resolution: Posted new garbage placards.
Communications › Alarms/Indicators › Bilge Alarm
Issued 17 March 2016 Resolved
Bilge audio and visual alrams on bridge were not operational.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 March 2016
Resolution: verified operational bilge alarms
Electrical › Electrical Distribution System (service) › Cable
Issued 17 March 2016 Resolved
Dead end cable loose and free behind the steerind counsel on bridge.
Action required: 705 - Other - as specified
Due 17 April 2016
Resolved 17 March 2016
Resolution: verifed properly ended non charged cables.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 17 March 2016 Resolved
EPIRB unable to float free. Need to relocate IAW 46CFR 184.30-5a in OLD T.
Action required: 705 - Other - as specified
Due 17 April 2016
Resolved 17 March 2016
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 17 March 2016 Resolved
02 Emergency lights found not operational. 01 Emergency light does not face emergency exit in engine room IAW 46 CFR 184.30-5a OLD T.
Action required: 705 - Other - as specified
Due 17 April 2016
Resolved 22 April 2016
Resolution: Verified emergency lighting installed at proper position.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 17 March 2016 Resolved
Hatch cover leading to steering gear room found to be leaking, compromising the water tight integrity of that water tight space. Needs to be adjusted IAW 46 CFR 185.25-5a OLD T.
Action required: 705 - Other - as specified
Due 31 March 2016
Resolved 22 April 2016
Resolution: Water hose tested the repaired hatch cover. All sat.

Casualty record · 2

15 March 2012Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4307055
15 June 2013Routine · role: Involved in a Marine Casualty · activity 4641147
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.