Records from 2012 to 2017. Most recent: inspection, 31 May 2017.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Communications › Public Address System › Loudspeaker
Issued 1 May 2017
Resolved
Currently no PA system installed.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 June 2017
Resolved 31 May 2017
Resolution: Witnessed sat operation of vsl P/A system.
Engineering › Bilge Water Management System › Strainer
Issued 1 May 2017
Resolved
Fore peak bilge system piping missing required strainer that is 3x the area opening.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 May 2017
Resolved 31 May 2017
Resolution: Verified new fwd peak bilge suction foot was installed and tested sat.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 1 May 2017
Resolved
Incorrect call sign
Condition: Invalid
Action required: 705 - Other - as specified
Due 14 May 2017
Resolved 11 May 2017
Resolution: Documents have been updated with correct call sign.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 1 May 2017
Resolved
Engine room lighting insufficient, lighting to dim.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 May 2017
Resolved 11 May 2017
Resolution: Battery has been replaced.
Engineering › Freshwater System (jacketwater cooling) › Storage Tank
Issued 13 March 2017
Resolved
STBD ship service generator J/W holding tank was corroded at the bottom and was actively leaking while the engine was running.
Action required: 705 - Other - as specified
Due 13 April 2017
Resolved 1 May 2017
Resolution: COI was revoked on 20APR2017, issued new COI on this date.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 13 March 2017
Resolved
FCC Safety Radio Certificate was expired
Action required: 705 - Other - as specified
Due 13 April 2017
Resolved 1 May 2017
Resolution: COI was revoked on 20APR2017, issued new COI on this date.
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 13 March 2017
Resolved
Bridge to Bridge Certificate was expired
Action required: 705 - Other - as specified
Due 13 April 2017
Resolved 1 May 2017
Resolution: COI was revoked on 20APR2017, issued new COI on this date.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 13 March 2017
Resolved
STBD fwd E/R bulkhead, had a weld seam crack.
Action required: 705 - Other - as specified
Due 13 April 2017
Resolved 1 May 2017
Resolution: COI was revoked on 20APR2017, issued new COI on this date.
Engineering › Fuel Oil Service System › Piping
Issued 13 March 2017
Resolved
F/O fill piping STBD side requires new clamps around the rubber hose portion. Port side fuel vent piping requires grounding cable.
Action required: 705 - Other - as specified
Due 13 April 2017
Resolved 1 May 2017
Resolution: COI was revoked on 20APR2017, issued new COI on this date.
Engineering › Fuel Oil Service System › Valve, Control
Issued 13 March 2017
Resolved
STBD reach rod for the fuel shutoff was broken on the deck, requires it to be re-welded
Action required: 705 - Other - as specified
Due 13 April 2017
Resolved 1 May 2017
Resolution: COI was revoked on 20APR2017, issued new COI on this date.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 13 March 2017
Resolved
Sewage type III, no holding tank, piping ovbd was open while in port
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 April 2017
Resolved 1 May 2017
Resolution: COI was revoked on 20APR2017, issued new COI on this date.
Electrical › Electrical Distribution System (service) › Cable
Issued 13 March 2017
Resolved
Multiple dead end wiring through out the vessel, require removal or proper termination.
Action required: 705 - Other - as specified
Due 13 April 2017
Resolved 1 May 2017
Resolution: COI was revoked on 20APR2017, issued new COI on this date.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 13 March 2017
Resolved
Emergency escape in galley needs to be determined of its adequacy as an escape.
Action required: 705 - Other - as specified
Due 13 April 2017
Resolved 1 May 2017
Resolution: COI was revoked on 20APR2017, issued new COI on this date.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 13 March 2017
Resolved
Crew state room in front of the E/R had loose and broken decking underneath the emergency escape ladder.
Action required: 705 - Other - as specified
Due 13 April 2017
Resolved 1 May 2017
Resolution: COI was revoked on 20APR2017, issued new COI on this date.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 13 March 2017
Resolved
Crew state room fwd port side requires cleaning, door entrance was hanging by one hinge, Emergency lighting was not mounted, Emergency escape requires the hinge door to open in the direction of escaping.
Action required: 705 - Other - as specified
Due 13 April 2017
Resolved 1 May 2017
Resolution: COI was revoked on 20APR2017, issued new COI on this date.
Engineering › Diesel Engine (propulsion-direct drive) › Block
Issued 13 March 2017
Resolved
Port MDE was overheating during normal running conditions. Cause is unknown. VSL owner is replacing with rebuilt (in kind) engine. Prove proper operation before placing vessel back in service.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 April 2017
Resolved 1 May 2017
Resolution: COI was revoked on 20APR2017, issued new COI on this date.
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 17 March 2016
Resolved
Master did not have an FCC Radio Permit as per 47 CFR 80.159.
Action required: 705 - Other - as specified
Due 17 April 2016
Resolved 19 April 2016
Resolution: Master provided proof of completion and application for FCC Marine Radio operators permit via Email to Marine Inspectors.
Documentation › Markings/Placards › Garbage Placard
Issued 17 March 2016
Resolved
Out of date MARPOL V Placard not IAW 33 CFR 151.59.
Action required: 705 - Other - as specified
Due 17 April 2016
Resolved 17 April 2016
Resolution: Posted new garbage placards.
Communications › Alarms/Indicators › Bilge Alarm
Issued 17 March 2016
Resolved
Bilge audio and visual alrams on bridge were not operational.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 March 2016
Resolution: verified operational bilge alarms
Electrical › Electrical Distribution System (service) › Cable
Issued 17 March 2016
Resolved
Dead end cable loose and free behind the steerind counsel on bridge.
Action required: 705 - Other - as specified
Due 17 April 2016
Resolved 17 March 2016
Resolution: verifed properly ended non charged cables.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 17 March 2016
Resolved
EPIRB unable to float free. Need to relocate IAW 46CFR 184.30-5a in OLD T.
Action required: 705 - Other - as specified
Due 17 April 2016
Resolved 17 March 2016
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 17 March 2016
Resolved
02 Emergency lights found not operational. 01 Emergency light does not face emergency exit in engine room IAW 46 CFR 184.30-5a OLD T.
Action required: 705 - Other - as specified
Due 17 April 2016
Resolved 22 April 2016
Resolution: Verified emergency lighting installed at proper position.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 17 March 2016
Resolved
Hatch cover leading to steering gear room found to be leaking, compromising the water tight integrity of that water tight space. Needs to be adjusted IAW 46 CFR 185.25-5a OLD T.
Action required: 705 - Other - as specified
Due 31 March 2016
Resolved 22 April 2016
Resolution: Water hose tested the repaired hatch cover. All sat.