Records from 2000 to 2010. Most recent: inspection, 27 October 2010.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Engineering › Generator (propulsion-electric) › Generator Voltage Regulator Circuitry
Issued 23 April 2009
Resolved
Need to prove to CG Inspector proper parallel operation of #1 Generator.
Action required: 705 - Other - as specified
Due 23 June 2009
Resolved 8 June 2009
Resolution: Received e-mail notifying use the generator had been repaired. Scanned e-mail into MISLE Activity 3498359.
Accommodation/Occupational Safety › Other Accommodation Spaces › Recreation Space
Issued 8 January 2009
Resolved
Make repairs to large hole in wall women’s head. 46CFR72.03-5 It appears that customers are throwing trash and cigarette butts into hole in wall.
Action required: 705 - Other - as specified
Due 29 January 2009
Resolved 8 June 2009
Resolution: Should have been cleared at last Qtrly inspection.
Lifesaving › Lifebuoys › Stowage
Issued 8 January 2009
Resolved
Mark all life buoys IAW 46CFR199.178.
Action required: 705 - Other - as specified
Due 31 January 2009
Resolved 8 June 2009
Resolution: Should have been cleared at last Qtrly inspection.
Fire Fighting › Means of Escape › Doorways
Issued 14 October 2008
Resolved
Replace latch for door on 1st deck "Cage". Post instruction sign and provide training for emergency exit procedures. (Crewmembers were unable to egress from space through door during fire drill due to faulty latch and lack of training).
Action required: 705 - Other - as specified
Due 22 October 2008
Resolved 29 October 2008
Fire Fighting › Means of Escape › Doorways
Issued 14 October 2008
Resolved
Make operable, doors on 1st deck in vicinity of rescue boat. Doors must be operable from both sides I.A.W. 46CFR72.05-25.
Action required: 705 - Other - as specified
Due 22 October 2008
Resolved 29 October 2008
Communications › Alarms/Indicators › Fire Alarm
Issued 30 July 2008
Resolved
Make operable, engineroom heat-detector located in overhead between generators.
Action required: 705 - Other - as specified
Due 6 August 2008
Resolved 20 August 2008
Communications › Alarms/Indicators › Engineers' Assistance-needed Alarm
Issued 30 July 2008
Resolved
Troubleshoot generator #2 high-jacket-water temperature alarm, and crank-case oil temperature alarm, as indicated at the main alarm panel.
Action required: 705 - Other - as specified
Due 6 August 2008
Resolved 5 August 2008
Fire Fighting › Fixed Gas Fire Extinguishing System › Quantity of Gas
Issued 30 July 2008
Resolved
Provide current servicing report for FM-200 cylinder that protects Computer/UPS space. Cylinder is currently tagged with a service date of 10/2005.
Action required: 705 - Other - as specified
Due 6 August 2008
Resolved 4 August 2008
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 30 July 2008
Resolved
Clean deck and liquid tray racks (dispensors) in liquor storage space.
Action required: 705 - Other - as specified
Due 6 August 2008
Resolved 4 August 2008
Electrical › Electric Generation Source (emergency) › Generator
Issued 16 April 2008
Resolved
Trouble-shoot and repair emergency generator "surge" condition.
Action required: 705 - Other - as specified
Due 24 April 2008
Resolved 22 April 2008
Electrical › Electric Generation Source (emergency) › Panelboard
Issued 16 April 2008
Resolved
Make operable the frequency meter for the emergency generator switchboard.
Action required: 705 - Other - as specified
Due 24 April 2008
Resolved 22 April 2008
Fire Fighting › Automatic Sprinkler System › Sprinklers
Issued 16 April 2008
Resolved
Two sprinkler heads in the 1B bar are located above the ceiling tiles, and without the proper head assembly. Properly loacate heads below tiles and install proper head assemblies.
Action required: 705 - Other - as specified
Due 24 April 2008
Resolved 22 April 2008
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 16 January 2008
Resolved
Fire damper for emergency generator space was not functional.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 January 2008
Resolved 16 January 2008
Resolution: Chief Engineer replaced acctuator during course of inspection. Tested sat.
Operations/Management › Drills/Instruction › Fire
Issued 20 July 2006
Resolved
Conduct weekly emergency drills with all personeel on the vessel, this enclude table games and FSS dept.
Action required: 705 - Other - as specified
Due 31 October 2006
Resolved 31 October 2006
Resolution: Completed to the satisfaction of the attending CG inspector.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 14 April 2006
Resolved
33U.S.C.1321(j)(5)(D)(iv)-The NTVRP does not address emergency procedures and qualified individual notification drills, and their frequencies
Due 14 May 2006
Resolved 30 October 2008
Documentation › Safety Management System › Emergency Drill/Exercise Programs
Issued 17 January 2006
Resolved
Expand emergency procedures manual, to be more expansive on steps. Create checklists for the Captain (ie - fire alarm, bomb threat, etc)
Action required: 705 - Other - as specified
Due 17 February 2006
Resolved 27 February 2006
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 17 January 2006
Resolved
Hoses for the CO2 system for the emergency generator room need to be replaced. All hoses are cracked.
Action required: 705 - Other - as specified
Due 24 February 2006
Resolved 27 February 2006
Fire Fighting › Fixed Halon Fire Extinguishing System › Quantity of Halon
Issued 17 January 2006
Resolved
Halon bottles located in Survillence Room need to be checked and renewed
Action required: 705 - Other - as specified
Due 19 January 2006
Resolved 27 February 2006
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 17 January 2006
Resolved
Clean and check all smoke detectors to ensure proper operation. Install additional smoke detector in lengends bar in upper deck.
Action required: 705 - Other - as specified
Due 19 January 2006
Resolved 9 March 2006
Resolution: Smoke detectors working.
Documentation › Markings/Placards › Warning Signs
Issued 17 January 2006
Resolved
Area behind Legends Bar is considered a dead end corridor, need to install a "This is not an exit" to make crew aware of area.
Action required: 705 - Other - as specified
Due 19 January 2006
Resolved 27 February 2006
Fire Fighting › Automatic Sprinkler System › Spare Sprinkler Heads
Issued 17 January 2006
Resolved
Covers for sprinkler heads need to be replaced throughout the vessel. All decks in multiple areas have covers missing.
Action required: 705 - Other - as specified
Due 18 January 2006
Resolved 9 March 2006
Resolution: sprinkler heads were all replaced.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 17 January 2006
Resolved
Remove all inhouse (homemade) power stripes throughout vsl. Only the power stripes authorized by the electrical plan are authorized. No extension cords.
Action required: 705 - Other - as specified
Due 17 February 2006
Resolved 17 January 2006
Stability › Watertight Integrity › General
Issued 17 January 2006
Resolved
Multiple thru hull fittings are missing rox blocks or puddy. Need to be replaced or installed.
Action required: 705 - Other - as specified
Due 24 January 2006
Resolved 27 February 2006
Lifesaving › Lifefloat › Lifeline
Issued 17 January 2006
Resolved
New lines on several life rings on outside of vsl need to be replaced.
Action required: 705 - Other - as specified
Due 24 January 2006
Resolved 27 February 2006
Personnel › Certificates/Documents/Licenses › License, Master
Issued 17 January 2006
Resolved
Vsl is required to maintain min manning requirements. They are not authorized to leave the vsl to conduct work in hotel. They are to stay on vsl IAW station bill, not maintenance in hotel, not cleaning hotel, etc. Marine crew for marine crew duties only.
Action required: 705 - Other - as specified
Due 17 January 2006
Resolved 27 February 2006
Resolution: this problem is in progress with management.
Documentation › Markings/Placards › Warning Signs
Issued 17 January 2006
Resolved
Due to remodel, vsl needs to replace all signage throughout the vsl with signage in good condition. All fire stations, all WTD's etc. Training needs to be conducted on WTD's opening and closing.
Action required: 705 - Other - as specified
Due 24 January 2006
Resolved 27 February 2006
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 17 January 2006
Resolved
Slot tech room - remove all combustables, remove all items that are blocking door ( secondary means of escape). remove paint locker or install thermal heat detector in room.
Action required: 705 - Other - as specified
Due 17 February 2006
Resolved 27 February 2006
Operations/Management › Drills/Instruction › Abandon Ship
Issued 17 January 2006
Resolved
New Emergency Evacuation Plan needs to be submitted and approved once all of the modifications are complete and implemented to MSC.
Action required: 705 - Other - as specified
Due 17 February 2006
Resolved 27 February 2006
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Nozzles
Issued 28 July 2005
Resolved
Install correct covers on sprinkler heads throughout the vessel (Soft/Hard Count).
Condition: Unknown
Due 3 August 2005
Resolved 3 August 2005
Resolution: Correct covers on sprinkler heads installed throughout vsl.
Construction/Loadline › Structures › Deck Plating
Issued 28 July 2005
Resolved
Fix deck in lower hold outside elevator.
Condition: Unknown
Due 27 August 2005
Resolved 26 August 2005
Resolution: Deck in lower hold outside elevator fixed.
Documentation › Safety/Response Plans/Programs › General Arrangement Plans
Issued 28 July 2005
Resolved
Expand confined entry plan.
Condition: Unknown
Due 27 August 2005
Resolved 26 August 2005
Resolution: Confined entry plan has been expanded.
Operations/Management › Drills/Instruction › Safety Orientation
Issued 25 April 2005
Resolved
Develop and implement a confined space entry procedures and logs for vsl.
Condition: Unknown
Due 21 May 2005
Resolved 1 June 2005
Resolution: Confined space entry procdures and logs developed and implemented.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 25 April 2005
Resolved
Repair life jacket box located on fwd bow. Additionally, re-stencil life rings.
Condition: Unknown
Due 21 May 2005
Resolved 8 June 2005
Resolution: Life jacket box on fwd box repaired, life rings restenciled.
Accommodation/Occupational Safety › Occupational Safety › Receptacle Outlet
Issued 25 April 2005
Resolved
1st Deck high roller room has dead end wires, cord/plug sticking out of wall - correct. Office - desk nearest door, remove all extenstion cords.
Condition: Unknown
Due 28 April 2005
Resolved 1 June 2005
Resolution: Dead end wires, cord/plug sticking out of wall on first deck corrected.
Deck/Cargo › Cargo Stowage › General
Issued 25 April 2005
Resolved
First deck stern, remove all items on back and remove lift of add weight to vsl calculations.
Condition: Unknown
Due 28 April 2005
Resolved 2 June 2005
Resolution: Lift and all other items removed from first deck stern.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Waste Heat Recovery
Issued 25 April 2005
Resolved
#2 SSGG Needs heater serviced.
Condition: Unknown
Due 1 June 2005
Resolved 1 June 2005
Resolution: #2 SSGG heater serviced.
Deck/Cargo › Cargo Stowage › General
Issued 25 April 2005
Resolved
Third deck Deli storage room, repair wall, three holes in drywall, replace cover on electrical box in wall.
Condition: Unknown
Due 1 June 2005
Resolved 1 June 2005
Resolution: Wall in third deck deli storage room repaired. Replaced cover on electrical box in wall.
Deck/Cargo › Cargo Stowage › General
Issued 25 April 2005
Resolved
Ensure all doors, storage lockers and restricted areas are locked IAW with plan.
Condition: Unknown
Due 1 June 2005
Resolved 1 June 2005
Resolution: All doors, storage lockers, and restricted areas are now locked IAW security plan.
Deck/Cargo › Cargo Stowage › General
Issued 25 April 2005
Resolved
Remove all plastic glasses tote from the vsl and remover any plastic milk crates.
Condition: Unknown
Due 21 May 2005
Resolved 13 June 2005
Resolution: All plastic glasses tote and plastic milk crates from vsl.
Operations/Management › Drills/Instruction › Fire
Issued 25 April 2005
No resolution recorded
Revise emergency evacuation plan and send to MSC for approval and port.
Condition: Unknown
Due 21 May 2005 — due date passed with no resolution recorded
Resolution: Emergency evacuation plan revised and sent to MSC for approval.
Electrical › Electrical Distribution System (service) › Wiring
Issued 29 September 2004
Resolved
Remove all inhouse fabricated power stripes on board vessel. Install and establish a maintainence and logging system for all additional power stripes that are installed.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 October 2004
Resolved 21 October 2004
Resolution: Have removed all power stripes that are home made and looking at manufactured power stripes.
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 29 September 2004
Resolved
Remove unknown substance in blkhd penetration and fill w/ approved fire caulk. Location: stbd fwd supply locker. Appears to have drywall caulking in penetration.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 October 2004
Resolved 14 October 2004
Resolution: Removed drywall caulking and replaced w/ approved fire caulking.
Construction/Loadline › Structures › Deck Plating
Issued 29 September 2004
Resolved
2nd deck aft bar, the deck penetration that holds all of the liquar hoses was filled in w/ expandable foam. Needs to be removed and replaced w/ fire caulk. Additionally, remove all cut hoses that are not being used.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 October 2004
Resolved 14 October 2004
Resolution: Removed expandable foam and filled w/ fire caulk.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 29 September 2004
Resolved
Replace retroreflective tape.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 October 2004
Resolved 14 October 2004
Resolution: Tape has been replaced.
Construction/Loadline › Structures › Machinery Space Opening
Issued 29 September 2004
Resolved
All WTD's need to have audiable alarm when shuting and opening during remote/manual shutting and opening. Ensure that alarm is operating properly.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 14 October 2004
Resolved 14 October 2004
Resolution: Alarms are operating properly.
Accommodation/Occupational Safety › Ventilation › General
Issued 29 September 2004
Resolved
In Card and Dice room a de-humidifer was installed. The de-humidifier has been damaged and the front cover is missing. Remove damaged de-humidifier.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 October 2004
Resolved 7 October 2004
Resolution: Damaged de-humidifier has been removed.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 29 September 2004
Resolved
Replace gauge located on switchboard. #2 wattmeter gauge and shorepower gauge and the shorepower gauge are unreadable. Replace with new gauges.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 October 2004
Resolved 2 November 2004
Resolution: Gauges were on back order. Have been installed.
Construction/Loadline › Penetrations › Valve Flange
Issued 29 September 2004
Resolved
Repair sewage leak located in fwd pump room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 October 2004
Resolved 14 October 2004
Resolution: Replaced faulty ball valve.
Engineering › Diesel Engine (propulsion-electric) › Piping (exhaust)
Issued 29 September 2004
Resolved
#2 SSG, determine cause of exhaust leak and repair.
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 October 2004
Resolved 14 October 2004
Resolution: Repaired exhaust leak.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 29 September 2004
Resolved
Outlet box located in soft count needs to be moved up to prevent objects from falling into the opening. By moving up, will close all of the openings.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 October 2004
Resolved 14 October 2004
Resolution: Outlet box moved up.
Construction/Loadline › Structures › Deck Plating
Issued 9 July 2004
Resolved
Epoxy deck covering, over structural fire protection concrete, in lower hold is broken. Fire concrete is exposed and being broken up over time.
Condition: Unknown
Action required: 705 - Other - as specified
Due 13 August 2004
Resolved 28 February 2005
Resolution: New epoxy on deck has been laid in designated areas.
Fire Fighting › Means of Escape
Issued 26 April 2004
Resolved
When fire pull on upper deck was pulled, the man catch doors on the other decks lock up. Fire pull for that deck needs to be pulled to release door and allow personnel to escape. Vessel is reconfiguring all man catch doors to open when any fire pull is activated. LEGACY COMPONENT DESC: Doorways
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 13 May 2004
Resolved 13 May 2004
Resolution: Corrected so that fire pulls to allow personnel to escape.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 26 April 2004
Resolved
Fix light on lifering located on the aft main deck port side.
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 April 2004
Resolved 26 April 2004
Resolution: Replaced battery in light.
Accommodation/Occupational Safety › Ventilation
Issued 26 April 2004
Resolved
Install damper for fresh air supply into the detention room. Vessel had duct taped off, removed tape.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 27 April 2004
Resolved 27 April 2004
Resolution: Installed damper for air.
Electrical › Electrical Distribution System (service)
Issued 26 April 2004
Resolved
Correct dead end wire runs located throughout vessel.
LEGACY COMPONENT DESC: Wiring
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 April 2004
Resolved 13 May 2004
Resolution: Corrected all dead end wire runs.
Electrical › Electrical Distribution System (service)
Issued 26 April 2004
Resolved
Correct plug-in for coke machine. LEGACY COMPONENT DESC: Outlet Box
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 27 April 2004
Resolved 11 May 2004
Resolution: Recieved and installed new hardware to correct.
Electrical › Electrical Distribution System (service)
Issued 28 January 2004
Resolved
Vessel has constructed/fabricated power stripes to place throughout the vessel to facilitate offices located in hold. Power stripes need to be submitted to MSC for approval. Vessel has submitted to MSC and are working through the process. LEGACY COMPONENT DESC: Outlet Box
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 February 2004
Resolved 16 February 2004
Resolution: MSC returned letter examined. OCMI has final approval on units.
Lifesaving › Buoyant Apparatus
Issued 8 October 2003
Resolved
Replace Life-Ring lights on 2nd and 3rd deck. LEGACY COMPONENT DESC: Life ring lights
Action required: 705 - Other - as specified
Due 15 October 2003
Resolved 20 October 2003
Construction/Loadline › Penetrations
Issued 8 October 2003
Resolved
Correct all deck penetrations throughout vessel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 November 2003
Resolved 20 October 2003
Fire Fighting › Fire Hoses
Issued 8 October 2003
Resolved
Hydro and stencil all 1 1/2 and 2 1/2 inch fire hoses.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 20 October 2003
Resolved 20 October 2003
Electrical › Lighting (emergency)
Issued 8 October 2003
Resolved
Main deck aft - overhead light extinguished, replace bulb
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 October 2003
Resolved 20 October 2003
Fire Fighting › Structural Fire Protection - General
Issued 8 October 2003
Resolved
All fire doors that are propped open, either remain closed or install magnetic releases.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 8 November 2003
Resolved 20 October 2003
Electrical › Electric Supply System (service)
Issued 8 October 2003
Resolved
Remove all power strips. Will accept UPC until perm. solution determined. Electrician conduct load analysis submit report.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 8 November 2003
Resolved 20 October 2003
Lifesaving › Rescue Boat
Issued 8 October 2003
Resolved
Cable on rescue boat is frayed. Needs to be cut off and repaired or replaced. LEGACY COMPONENT DESC: Cable Falls
Action required: 705 - Other - as specified
Due 8 November 2003
Resolved 8 October 2003
Lifesaving › Rescue Boat
Issued 8 October 2003
Resolved
Prove dates on cable falls and determine if vessel will replace at 30 months or turn end for end. LEGACY COMPONENT DESC: Cable Falls
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 8 November 2003
Resolved 20 October 2003
Resolution: Replaced.
Electrical
Issued 8 October 2003
Resolved
Install stuffing box material sewer transfer through hole aft main deck starboard side.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 October 2003
Resolved 20 October 2003
Construction/Loadline › Structures
Issued 8 October 2003
Resolved
Hook up emergency generator room ventilation ducts. LEGACY COMPONENT DESC: Ventilators
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 8 October 2003
Resolved 8 October 2003
Engineering › Diesel Engine (auxiliary)
Issued 8 October 2003
Resolved
Replace F/O gauge and repair coolant leaks emergency generator room.
Action required: 705 - Other - as specified
Due 8 October 2003
Resolved 20 October 2003
Construction/Loadline › Penetrations
Issued 8 October 2003
Resolved
Prove proper operation IAW operational manual on water tight sliding doors. LEGACY COMPONENT DESC: WTD
Action required: 705 - Other - as specified
Due 15 October 2003
Resolved 20 October 2003
Electrical › Electric Generation Source (service)
Issued 30 September 2003
Resolved
Effect repairs to .4 amp ground detected in G-106 panel. LEGACY COMPONENT DESC: Ground Detection
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 October 2003
Resolved 20 October 2003
Electrical › Electric Supply System (service)
Issued 30 September 2003
Resolved
Remove all extension cords from vessel.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 8 October 2003
Resolved 20 October 2003
Electrical › Electrical Distribution System (service)
Issued 6 August 2003
Resolved
Remove power strips from the surveillance room & viewing room LEGACY COMPONENT DESC: Outlet Box
Condition: Improper Installation
Due 6 September 2003
Resolved 8 October 2003
Electrical › Electrical Distribution System (service)
Issued 6 August 2003
Resolved
Replace wall mounted receptacle outlet with marine grade or approved UL grade in Security Room (Security Dispatch). LEGACY COMPONENT DESC: Outlet Box
Condition: Improper Installation
Due 6 September 2003
Resolved 8 October 2003
Electrical › Lighting (emergency)
Issued 6 August 2003
Resolved
Label all emergency lights on vessel. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper Installation
Due 6 September 2003
Resolved 8 October 2003
Fire Fighting › Means of Escape
Issued 6 August 2003
Resolved
Label kickout panels on all doors. LEGACY COMPONENT DESC: Escape Route Signs
Condition: Improper Installation
Due 6 September 2003
Resolved 8 October 2003
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 6 August 2003
Resolved
CO2 Room - Correct wire run and stop. Wire has been added not allowing for correct operation. And fire damper limit switch wire needs to be reconnected.
Condition: Improper Installation
Due 6 September 2003
Resolved 30 September 2003
Resolution: Will check on next quarterly examination.
Electrical › Electrical Distribution System (service)
Issued 26 January 2003
Resolved
Provide log of ground fault indications at the beginning of each C.E. watch. Note ground fault conditions and work done to clear faults. LEGACY COMPONENT DESC: Ground Detection
Due 1 March 2003
Resolved 10 February 2003
Construction/Loadline › Structures
Issued 26 January 2003
Resolved
Provide guards to protect hydraulic pipe lines at the watertight doors, where exposed. LEGACY COMPONENT DESC: Machinery Space Opening
Due 1 March 2003
Resolved 10 February 2003
Personnel › Training
Issued 9 October 2002
Resolved
Prove monthly training requirements have been met by Leander Roque.
Due 9 November 2002
Resolved 15 November 2002
Personnel › Training
Issued 9 October 2002
Resolved
Provide training records for individuals of security dept, housekeeping and pit managers.
Due 9 November 2002
Resolved 11 October 2002
Resolution: Corrected.
Electrical › Electrical Distribution System (service)
Issued 9 October 2002
Resolved
Provide weatherproof duplex outlets or relocate outlets out of wet bar area's. LEGACY COMPONENT DESC: Outlet Box
Due 9 November 2002
Resolved 11 October 2002
Resolution: Corrected.
Electrical › Electrical Distribution System (service) › Cable
Issued 9 October 2002
Resolved
Repair or remove dead end electrical cable in slot cage "C".
Due 9 November 2002
Resolved 11 October 2002
Resolution: Corrected.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 9 October 2002
Resolved
Provide cover for junction box in overhead, stbd side of forward machinery space.
Due 9 November 2002
Resolved 11 October 2002
Resolution: Corrected.
Fire Fighting › Automatic Sprinkler System › Pressure Tank
Issued 9 October 2002
Resolved
Replace check valve on sprinkler tank air inlet supply from air compressor.
Due 9 November 2002
Resolved 11 October 2002
Resolution: Corrected.
Accommodation/Occupational Safety › Occupational Safety
Issued 9 October 2002
Resolved
Remove retaining screws on kick out panel for door leading to liquor storage.
Due 9 November 2002
Resolved 11 October 2002
Resolution: Corrected.
Fire Fighting › Automatic Sprinkler System
Issued 9 October 2002
Resolved
Provide sprinkler tank low psi alarm as required by 46 CFR 76.25-20. LEGACY COMPONENT DESC: Pressure Tank
Due 9 November 2002
Resolved 15 November 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 23 July 2002
Resolved
Repair/ replace the broken hand rails in the passenger stairtowers. They should be able to take a 200 lb force in any direction. LEGACY COMPONENT DESC: Hand Grab
Due 25 August 2002
Resolved 9 October 2002
Resolution: Corrected.
Operations/Management › Drills/Instruction
Issued 17 April 2002
Resolved
Provide training and drill records for all persons on the muster list.
Due 17 May 2002
Resolved 22 May 2002
Resolution: Corrected via ltr from [name withheld] and C/E Calogero.
Operations/Management
Issued 17 April 2002
Resolved
Provide muster list for approval.
Due 17 May 2002
Resolved 22 May 2002
Resolution: Corrected via ltr from [name withheld] and C/E Calogero.
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 17 April 2002
Resolved
Clean up deck in all bar service area's. Secure water leaks under bar service area's.
Due 17 May 2002
Resolved 19 April 2002
Resolution: Corrected.
Fire Fighting › Nozzles
Issued 17 April 2002
Resolved
Provide spud chains on all fire nozzle's.
Due 17 May 2002
Resolved 19 April 2002
Resolution: Corrected.
Electrical › Electrical Distribution System (service)
Issued 17 April 2002
Resolved
Properly install electrical wiring in all pits for table games (to include pipe penetrations, fire stop and duplex outlet boxes). LEGACY COMPONENT DESC: Cable
Due 17 May 2002
Resolved 3 June 2002
Electrical › Electrical Distribution System (service) › Panelboard
Issued 17 April 2002
Resolved
Provide keys for all circuit breaker boxes.
Due 17 May 2002
Resolved 19 April 2002
Resolution: Corrected.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 17 April 2002
Resolved
Prove proper operation of smoke detectors.
Due 17 May 2002
Resolved 19 April 2002
Resolution: Corrected.
Fire Fighting › Combustible Materials › Linings
Issued 17 April 2002
Resolved
Ensure trash is placed into metal trash cans.
Due 17 May 2002
Resolved 19 April 2002
Resolution: Corrected.
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 17 April 2002
Resolved
Add portable fire extinguisher to main deck cage and update fire safety plan.
Due 17 May 2002
Resolved 22 May 2002
Resolution: Corrected via ltr from [name withheld] and C/E Calogero.
Accommodation/Occupational Safety › Occupational Safety
Issued 17 April 2002
Resolved
Properly install 110v duplex outlet at main deck cage. LEGACY COMPONENT DESC: Receptacle Outlet
Due 17 May 2002
Resolved 22 May 2002
Resolution: Corrected via ltr from [name withheld] and C/E Calogero.
Accommodation/Occupational Safety › Occupational Safety › Receptacle Outlet
Issued 17 April 2002
Resolved
Provide cover for duplex outlet at main deck cage.
Due 17 May 2002
Resolved 19 April 2002
Resolution: Corrected.
Accommodation/Occupational Safety › Occupational Safety
Issued 17 April 2002
Resolved
Properly install outlet strips in main deck cage. LEGACY COMPONENT DESC: Receptacle Outlet
Due 17 May 2002
Resolved 22 May 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 17 April 2002
Resolved
Remove outlet strips that contain solid conductors. LEGACY COMPONENT DESC: Receptacle Outlet
Due 17 May 2002
Resolved 3 June 2002
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 17 April 2002
Resolved
Prove proper operation of man traps at all cages.
Due 17 May 2002
Resolved 19 April 2002
Resolution: Corrected.
Fire Fighting › Ventilation Systems
Issued 17 April 2002
Resolved
Relocate forward machinery space ventillation shutdown switch to outside the space.
Due 17 May 2002
Resolved 19 April 2002
Resolution: Corrected.
Fire Fighting › Structural Fire Protection - General
Issued 17 April 2002
Resolved
Replace stuffing blocks at cable penetrations above watertight door leading to forward machinery space.
Due 17 May 2002
Resolved 19 April 2002
Resolution: Corrected.
Fire Fighting › Structural Fire Protection - General
Issued 17 April 2002
Resolved
Replace stuffing blocks at cable penetrations in engineroom above transformer next to engineroom entrance and above drinking fountain.
Due 17 May 2002
Resolved 19 April 2002
Resolution: Corrected.
Fire Fighting
Issued 10 October 2001
Resolved
Provide additional training to senior deck hands to meet minimum requirements.
Condition: Unknown
Due 10 January 2002
Resolved 25 January 2002
Resolution: Examined during quarterly inspection. Act # 1477656
Documentation
Issued 10 October 2001
Resolved
Complete and log all required operational test as required by 46 CFR 78-17.
Condition: Unknown
Due 10 January 2002
Resolved 25 January 2002
Resolution: Examined during quarterly inspection. Act # 1477656
Fire Fighting
Issued 10 October 2001
Resolved
Provide pump curve report for Sprinkler System._x001C_
Condition: Unknown
Due 28 November 2001
Resolved 28 November 2001
Fire Fighting
Issued 23 July 2001
Resolved
Correct the latch problems on all fire screen doors._x001C_
Condition: Unknown
Due 23 July 2001
Resolved 23 July 2001