MAURY USCG vessel records
← All vessels

NORDIC KYLIE

NORDIC KYLIE is a freight ship. The Coast Guard has recorded 19 inspections since 2016, most recently in February 2026, along with 16 deficiencies and 3 operational controls.

Records from 2016 to 2026. Most recent: inspection, 17 February 2026.

Built
Not recorded
Last inspected
17 February 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9357999
854352
Flag
LIBERIA
Maury page id
psix-854352

Inspections, by type

…with no type recorded2
Years with a record 8 calendar years (2016–2026)
The 19 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Documentation record

Tonnage as PSIX records it9611 - Convention (Subpart B), Gross Ton
4260 - Convention (Subpart B), Net Ton
12760 - Dead Weight, Ton
17972 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspection history · 19

17 February 2026 PSC B
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8309674
25 June 2025 PSC B
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8160966
20 December 2024 PSC B
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 8049062
18 December 2024 Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8048746
11 December 2024 PSC B · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8044678
8 December 2024 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8044616
4 December 2024 Deficiency Check · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8046028
4 May 2024 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7906584
3 May 2024 PSC B · Ballast Water Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7901559
3 May 2024 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7906307
16 May 2022 PSC B · Deficiency Check
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7448691
10 May 2022 Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7447711
1 June 2021 Ballast Water Examination · PSC B
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7206810
26 May 2021 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7212117
25 May 2021 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7206819
14 May 2020 PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6952146
7 August 2017 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6225974
7 August 2017 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6226547
16 August 2016 ISPS II Exam · Joint Vessel Security Verification (Massena only)
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 5975976

Deficiency record · 16

02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 25 June 2025 Resolved
The steering gear compartments shall include hand rails and gratings or other nonslip surfaces to ensure suitable working conditions in the event of a hydraulic leak. PSCO observed no nonskid surface in steering gear room. 74solas(04)II-1 29.13.2 40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 25 August 2025
Resolved 25 June 2025
Resolution: Received class report attesting to satisfactory rectification
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 11 December 2024 Resolved
FIREFIGHTING SYSTEMS AND APPLIANCES SHALL BE KEPT IN GOOD WORKING ORDER AND READILY AVAILABLE FOR IMMEDIATE USE. PSCO OBSERVED PILOT HOSES FOR FIXED CO2 SYSTEM COMPLETELY MISSING OUTER PROTECTIVE LAYER. 74SOLAS(20) II-2/14.2.1.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 December 2024
Resolution: PSCO attended vessel and verified hoses replaced
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 11 December 2024 Resolved
BEFORE THE SHIP LEAVES PORT AND AT ALL TIMES DURING THE VOYAGE, ALL LIFE-SAVING APPLIANCES SHALL BE IN WORKING ORDER AND READY FOR IMMEDIATE USE. PSCO OBSERVED FREEFALL LIFEBOAT WOULD BARELY STEER TO PORT AND EXCESSIVELY TO STARBOARD. 74SOLAS(20) III/20.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 December 2024
Resolution: PSCO attended vessel and observed satisfactory steering test of life boat
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 11 December 2024 Resolved
Structural fire protection, including fire-resisting divisions, and protection of openings and penetrations in divisions shall be kept in good working order so as to ensure required performance. PSCO observed hospital space door to the exterior deck would not completely close. 74SOLAS(20) II-2/14.2.1.1.1
Action required: 10 - Deficiency Rectified
Resolved 11 December 2024
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 4 May 2024 Resolved
All ships of 3000 gross tonnage and upwards shall have a 3 GHz radar or where considered appropriate by the Administration a second 9GHz radar, or other means to determine and display the range and bearing of other surface craft, obstructions, buoys, shorelines and navigational marks to assist in navigation and in collision avoidance which are functionally independent of those referred to in paragraph 2.3.2. Vessel has inoperable S-Band Radar and unable to repair in port.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 21 May 2024
Resolved 4 December 2024
Resolution: Received class survey report attesting to the repair and operability of the radars.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Other (ISM)
Issued 3 May 2024 Resolved
15113 - EVERY COMPANY SHOULD MAINTAIN A SAFETY MANAGEMENT PLAN WHICH INCLUDES: INSTRUCTIONS AND PROCEDURES TO ENSURE SAFE OPERATION OF THE SHIP. VESSEL FAILED TO IMPLEMENT ITS SMS. MULTIPLE COMPUTERS WIHT NETWORK ACCESS WRE NOT LOCKED AND COMPUTER IN ECR HAD LOGIN USERNAME AND PASSWORD POSTED ON MONITOR. REQUIRE INTERNAL AUDIT TO ENSURE SMS CYBER HYGIENE IMPLEMENTATION. 74SOLAS(20) IX/3.1, ISM CODE 1.4
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 3 June 2024
Resolved 4 December 2024
Resolution: received flag action report attesting to crew training on cyber security and cyber hygiene implementation, and the removal of password stickers from work stations.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 May 2024 Resolved
02108 - EACH SEPERATE CIRCUIT SHALL BE PROTECTED AGAINST SHORT CIRCUIT. FOUND LARGE QUANTITY OF CIRCUIT BREAKERS/FUSES IN ENGINE CONTROL ROOM MAIN SWITCHBOARD AND E-GEN HAVE OVERRATED CIRCUIT PROTECTION INSTALLED. INSPECT ALL BREAKERS AND ENSURE APPROPRIATE RATED BREAKER IS INSTALLED.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 3 June 2024
Resolved 4 December 2024
Resolution: received flag action report attesting to the installation of correctly rated circuit breakers for the main switchboard and e-gen.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 16 May 2022 Resolved
A food ration totalling not less than 10000KJ for each person the lifeboat is permitted to accommodate; these rations shall be kept in airtight packaging. 8 of the 20 food rations in the lifeboat were found not airtight due to damaged packaging.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 23 May 2022
Resolution: Received 08 Seven Oceans food rations while in port in Montreal from Clipper Ship Supply Inc. Receipt provided.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 2 June 2021 Resolved
Each liferaft or group of liferafts shall be stowed with a float-free arrangement complying with the requirements of paragraph 4.1.6 of the code so that each flotas free and, if inflatable, inflates automatically when the ship sinks. Liferaft painter line attached to ship preventing float free arrangemens.
Action required: 17 - Rectify deficiencies prior to departure
Due 2 June 2021
Resolved 2 June 2021
Resolution: Liferaft painter tape was attached to Hydraulic release unit fixing deficiencies.
10 - Safety of Navigation › N/A - No Subsystem › Voyage data recorder (VDR)/Simplified Voyage data recorder(S-VDR)
Issued 25 May 2021 Resolved
INOP W/ DEFECTIVE FRM (FINAL RECORDING MEDIUM)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 May 2021
Resolution: Recieved technician report attesting to proper operation of VDR.
Lifesaving › Rescue Boat › Hull (rigid)
Issued 8 August 2017 Resolved
Maintenance, testing, and inspections of life saving appliances shall be carried out based on the guidelines developed by the organization. The rescue boat has multiple material discrepancies (through fiberglass hull fractures, fractures on transom on both sides of outboard, failed rub rail, and fiberglass separation at stern arch fastening).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 August 2017
Resolved 11 August 2017
Resolution: Temporary repairs conducted, flag state dispensation for permanenet repairs issued.
Lifesaving › Lifebuoys › Serviceable
Issued 8 August 2017 Resolved
Before ship leaves port and at all times during the voyage all life saving appliances shall be in working order. Both 4 kg bridge wing lifebuoys are in unserviceable condition.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 August 2017
Resolved 11 August 2017
Resolution: Replaced with new ring lifebuoy.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 8 August 2017 Resolved
Every ship other than an oil tanker of 400 GT shall carry a SOPEP approved by the administration. Ships SOPEP requires testing of all pollution prevention equipment and bilge systems monthly. Chief Engineer stated that currently the OWS is not being run as a complete unit. Only the Oil Content Meter is being tested.
Due 7 September 2017
Resolved 11 August 2017
Resolution: OWS unit tested in presence of class. OWS PMS will be updated to reflect OWS testing/ SOPEP requirements.
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 8 August 2017 Resolved
Rudder indicators to determine and display rudder angle are to be readable from the conning station. The repeater on the STBD bridge wing shows a 5 degree difference from the main bridge rudder angle indicator when rudder is 35 degrees to port or stbd.
Due 7 September 2017
Resolved 15 May 2020
Resolution: Rudder angle indicator shows proper readings.
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 8 August 2017 Resolved
Machinery spaces of CAT A above 500 M3 shall be protected by an approved fixed water based system. The infrared detector for the incinerator has a non manufacturer focus tube installed.
Action required: 705 - Other - as specified
Due 7 September 2017
Resolved 11 August 2017
Resolution: Infrared detector replaced with manufacturer's recommended tube.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 8 August 2017 Resolved
Firefighting appliances shall be kept in good working order. Multiple fire extinguishers were unserviceable due to kinked discharge hose. Ships spares were used to replace.
Due 8 August 2017
Resolved 8 August 2017
Resolution: Ships spares were uses. Crew was instructed to order replacement parts.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.