← All vessels
NORDIC KYLIE
NORDIC KYLIE is a freight ship. The Coast Guard has recorded 26 inspections since 2006, most recently in February 2026, along with 17 deficiencies and 4 operational controls.
Records from 2006 to 2026. Most recent: inspection, 17 February 2026.
- Built
- Not recorded
- Last inspected
- 17 February 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 17 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9357999 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
D5YL7
854352
Flag
LIBERIA
—
Maury page id
psix-854352
Inspections, by type
…with no type recorded3
Years with a record
12 calendar years (2006–2026)
The 26 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it9611 - Convention (Subpart B), Gross Ton
4260 - Convention (Subpart B), Net Ton
12760 - Dead Weight, Ton
17972 - Displacement, Ton
4260 - Convention (Subpart B), Net Ton
12760 - Dead Weight, Ton
17972 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 26
17 February 2026
PSC B
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8309674
25 June 2025
PSC B
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8160966
20 December 2024
PSC B
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 8049062
18 December 2024
Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8048746
11 December 2024
PSC B · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8044678
8 December 2024
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8044616
4 December 2024
Deficiency Check · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8046028
4 May 2024
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7906584
3 May 2024
PSC B · Ballast Water Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7901559
3 May 2024
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7906307
16 May 2022
PSC B · Deficiency Check
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7448691
10 May 2022
Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7447711
1 June 2021
Ballast Water Examination · PSC B
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7206810
26 May 2021
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7212117
25 May 2021
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7206819
14 May 2020
PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6952146
7 August 2017
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6225974
7 August 2017
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6226547
16 August 2016
ISPS II Exam · Joint Vessel Security Verification (Massena only)
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 5975976
24 March 2014
Ballast Water Examination · PII Safety Exam · ISPS III Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4819470
4 February 2008
Deficiency Check
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 3141333
27 September 2007
ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 3067155
18 September 2007
Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 3071420
18 June 2007
Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2967130
14 September 2006
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2773148
8 September 2006
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2773235
Deficiency record · 17
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 25 June 2025
Resolved
The steering gear compartments shall include hand rails and gratings or other nonslip surfaces to ensure suitable working conditions in the event of a hydraulic leak. PSCO observed no nonskid surface in steering gear room. 74solas(04)II-1 29.13.2 40ac
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 11 December 2024
Resolved
FIREFIGHTING SYSTEMS AND APPLIANCES SHALL BE KEPT IN GOOD WORKING ORDER AND READILY AVAILABLE FOR IMMEDIATE USE. PSCO OBSERVED PILOT HOSES FOR FIXED CO2 SYSTEM COMPLETELY MISSING OUTER PROTECTIVE LAYER. 74SOLAS(20) II-2/14.2.1.2
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 11 December 2024
Resolved
BEFORE THE SHIP LEAVES PORT AND AT ALL TIMES DURING THE VOYAGE, ALL LIFE-SAVING APPLIANCES SHALL BE IN WORKING ORDER AND READY FOR IMMEDIATE USE. PSCO OBSERVED FREEFALL LIFEBOAT WOULD BARELY STEER TO PORT AND EXCESSIVELY TO STARBOARD.
74SOLAS(20) III/20.2
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 11 December 2024
Resolved
Structural fire protection, including fire-resisting divisions, and protection of openings and penetrations in divisions shall be kept in good working order so as to ensure required performance. PSCO observed hospital space door to the exterior deck would not completely close. 74SOLAS(20) II-2/14.2.1.1.1
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 4 May 2024
Resolved
All ships of 3000 gross tonnage and upwards shall have a 3 GHz radar or where considered appropriate by the Administration a second 9GHz radar, or other means to determine and display the range and bearing of other surface craft, obstructions, buoys, shorelines and navigational marks to assist in navigation and in collision avoidance which are functionally independent of those referred to in paragraph 2.3.2. Vessel has inoperable S-Band Radar and unable to repair in port.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Other (ISM)
Issued 3 May 2024
Resolved
15113 - EVERY COMPANY SHOULD MAINTAIN A SAFETY MANAGEMENT PLAN WHICH INCLUDES: INSTRUCTIONS AND PROCEDURES TO ENSURE SAFE OPERATION OF THE SHIP. VESSEL FAILED TO IMPLEMENT ITS SMS. MULTIPLE COMPUTERS WIHT NETWORK ACCESS WRE NOT LOCKED AND COMPUTER IN ECR HAD LOGIN USERNAME AND PASSWORD POSTED ON MONITOR. REQUIRE INTERNAL AUDIT TO ENSURE SMS CYBER HYGIENE IMPLEMENTATION. 74SOLAS(20) IX/3.1, ISM CODE 1.4
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 May 2024
Resolved
02108 - EACH SEPERATE CIRCUIT SHALL BE PROTECTED AGAINST SHORT CIRCUIT. FOUND LARGE QUANTITY OF CIRCUIT BREAKERS/FUSES IN ENGINE CONTROL ROOM MAIN SWITCHBOARD AND E-GEN HAVE OVERRATED CIRCUIT PROTECTION INSTALLED. INSPECT ALL BREAKERS AND ENSURE APPROPRIATE RATED BREAKER IS INSTALLED.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 16 May 2022
Resolved
A food ration totalling not less than 10000KJ for each person the lifeboat is permitted to accommodate; these rations shall be kept in airtight packaging. 8 of the 20 food rations in the lifeboat were found not airtight due to damaged packaging.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 2 June 2021
Resolved
Each liferaft or group of liferafts shall be stowed with a float-free arrangement complying with the requirements of paragraph 4.1.6 of the code so that each flotas free and, if inflatable, inflates automatically when the ship sinks. Liferaft painter line attached to ship preventing float free arrangemens.
10 - Safety of Navigation › N/A - No Subsystem › Voyage data recorder (VDR)/Simplified Voyage data recorder(S-VDR)
Issued 25 May 2021
Resolved
INOP W/ DEFECTIVE FRM (FINAL RECORDING MEDIUM)
Lifesaving › Rescue Boat › Hull (rigid)
Issued 8 August 2017
Resolved
Maintenance, testing, and inspections of life saving appliances shall be carried out based on the guidelines developed by the organization. The rescue boat has multiple material discrepancies (through fiberglass hull fractures, fractures on transom on both sides of outboard, failed rub rail, and fiberglass separation at stern arch fastening).
Lifesaving › Lifebuoys › Serviceable
Issued 8 August 2017
Resolved
Before ship leaves port and at all times during the voyage all life saving appliances shall be in working order. Both 4 kg bridge wing lifebuoys are in unserviceable condition.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 8 August 2017
Resolved
Every ship other than an oil tanker of 400 GT shall carry a SOPEP approved by the administration. Ships SOPEP requires testing of all pollution prevention equipment and bilge systems monthly. Chief Engineer stated that currently the OWS is not being run as a complete unit. Only the Oil Content Meter is being tested.
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 8 August 2017
Resolved
Rudder indicators to determine and display rudder angle are to be readable from the conning station. The repeater on the STBD bridge wing shows a 5 degree difference from the main bridge rudder angle indicator when rudder is 35 degrees to port or stbd.
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 8 August 2017
Resolved
Machinery spaces of CAT A above 500 M3 shall be protected by an approved fixed water based system. The infrared detector for the incinerator has a non manufacturer focus tube installed.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 8 August 2017
Resolved
Firefighting appliances shall be kept in good working order. Multiple fire extinguishers were unserviceable due to kinked discharge hose. Ships spares were used to replace.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 27 September 2007
Resolved
REPAIR HOLE IN DISCHARGE PIPING ON OWS. CLASS TO ATTEST TO PROPER OPERATION OF OILY WATER SEPARATOR.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.