MAURY USCG vessel records Sign in
← All vessels

SPIRIT OF INDEPENDENCE

SPIRIT OF INDEPENDENCE is a 1995 passenger vessel (inspected). The Coast Guard has recorded 31 inspections since 2008, most recently in August 2025, along with 107 deficiencies and 2 operational controls.

Records from 2008 to 2025. Most recent: inspection, 22 August 2025.

Built
1995
Last inspected
22 August 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDE2236
855184
Flag
UNITED STATES
366056000, 367529640, 367697830 (licence lapsed)
Maury page id
psix-855184

Inspections, by type

Years with a record 15 calendar years (2008–2025)
The 31 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)61.5 ft × 17.0 ft × 8.0 ft
Registered tonnagegross 41 / net 37
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJ.C.WATERS · INDEPENDENCE, MO, UNITED STATES · built 1995
Hull materialSteel
PropulsionAuxiliary Sail
Hull shapeSail (Distinct Keel)
Hull configurationMonohull
Hailing portKEY WEST, FL
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 30 June 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it41 - Simplified, Gross Ton
37 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDI4357MMSI 367697830 · expired · voluntarily equipped · granted 20 October 2015, cancelled 7 March 2026
WDG3787MMSI 367529640 · expired · compulsorily equipped · granted 9 May 2012, cancelled 9 July 2022
WDE2236MMSI 366056000 · expired · compulsorily equipped · granted 10 November 2007, cancelled 13 January 2018
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 31

22 August 2025 Deficiency Check · COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8213580
11 August 2025 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8207132
5 September 2024 Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8014235
5 August 2024 Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7967538
12 June 2023 Deficiency Check · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7714246
5 June 2023 Administrative Inspection · In-Service Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7709316
9 May 2023 COI Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7679332
14 December 2022 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7609144
2 September 2022 Administrative Inspection · Internal Structural Exam · Drydock Exam · Examination of Repairs · In-Service Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7554955
9 August 2022 Annual Inspection · Deficiency Check · In-Service Inspection · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7527794
20 October 2021 In-Service Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7332826
9 August 2021 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7281568
13 October 2020 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7075990
1 September 2020 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7042500
17 September 2019 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6813685
10 September 2019 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6808700
10 April 2018 Internal Structural Exam · Drydock Exam · COI Inspection · DAPI Audit · Administrative Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6388860
15 May 2017 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6146293
24 March 2017 Examination of Repairs · Damage Survey · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6126106
15 August 2016 Annual Inspection · Internal Structural Exam · Deficiency Check · Drydock Exam · DAPI Audit · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5974491
5 October 2015 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5975051
1 October 2014 Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4999243
7 May 2012 Deficiency Check · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4307410
6 January 2012 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4223063
30 November 2010 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3901302
16 November 2010 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3885723
21 October 2010 Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3871902
21 October 2010 In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3883393
15 January 2010 Annual Inspection · DAPI Audit
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3660071
22 October 2008 Initial Certification
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2829040
20 October 2008 Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3144339

Deficiency record · 107

07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 12 August 2024 Resolved
A pre-engineered fixed gas fire extinguishing system must automatically shut down all engines that draw intake air from within the protected space and have a means to reset (override position). Prove proper operation of the Fireboy's automatic shutdown and override prior to carrying passengers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 August 2024
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 5 August 2024 Resolved
Provide and document Employee Assistance Program training to all crewmembers. Personnel in a supervisory position must receive 60 minutes of training.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 August 2024
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 13 June 2023 Resolved
Vessel operator reported a leak in their dry exhaust piping in the vibration baffle. Repair leak or replace baffle and suitably insulate section prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 June 2023
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 9 May 2023 Resolved
Install hand tiller and demonstrate auxiliary steering prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 May 2023 Resolved
All child size life jackets are stowed below deck. Move child size life jackets to a stowage location on deck and mark location.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 May 2023
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 9 May 2023 Resolved
Replace all expired medications in the vessel's first aid kit.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 May 2023
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 2 September 2022 Resolved
Conduct post Mast Inspection sea trials prior to carrying passengers under sail.
Action required: 705 - Other - as specified
Resolved 26 October 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 August 2022 Resolved
Life jackets must be stored in convenient places distributed throughout the accommodation spaces. All life jackets are being stored in below deck accommodation spaces with no life jackets stored on deck. Store 24 life jackets on deck for the maximum normal contingent of passengers and crew on board during excursion voyages.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 August 2022
Resolved 26 October 2022
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 12 August 2022 Resolved
Each EPIRB must be tested monthly and logged or otherwise documented. Develop an EPIRB log and test monthly.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 August 2022
Resolved 26 October 2022
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 12 August 2022 Resolved
Update the vessel's Sail Rigging Preventative Maintenance Plan with routine maintenance and inspection conducted by the crew as well as a the current inventory with installation dates. Provide electronic copy to US Coast Guard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 August 2022
Resolved 17 April 2023
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 12 August 2022 Resolved
On vessel's with overnight accommodations, Fire fighting training must include monthly emergency egress drills. Conduct and log or otherwise document the training.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 August 2022
Resolved 26 October 2022
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 9 August 2022 Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel did not undergo an annual inspection prior to August 9, 2022 and must undergo one prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 August 2022
Resolution: Conducted Annual Inspection.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 29 October 2021 Resolved
The master shall keep a correct, written count of all passengers that embark on and disembark from the vessel. Prior to departing on a voyage, the passenger count must be communicated verbally or in writing and available at shore at the vessel's normal berthing location or with a representative and shall be available to the Coast Guard upon request. Passenger count not kept ashore and passenger count not logged for 27OCT21 voyage.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 November 2021
Resolved 8 November 2021
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 29 October 2021 Resolved
Each vessel must be equipped with a public address system. A battery powered bullhorn may serve as the PA system if the bullhorn's batteries are continually maintained at a fully charged level. Bullhorn not sufficient currently for communication throughout vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 November 2021
Resolved 12 August 2022
Resolution: Bullhorn checked and cleared during Annual Inspection.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 28 October 2021 Resolved
Each accommodation space on a vessel with overnight accommodations for passengers must be fitted with an independent modular smoke detecting and alarm unit. 4 of 6 smoke detectors tested were inoperable. Vessel not permitted to carry overnight passengers until rectified.
Action required: 705 - Other - as specified
Due 28 October 2021
Resolved 29 October 2021
Resolution: Batteries replaced.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 30 August 2021 Resolved
Required training not logged in over three months.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 September 2021
01 - Certificates & Documentation › 013 - Documents › Ship specific plans for the recovery of persons from the water
Issued 30 August 2021 Resolved
Vessel's crew did not demonstrate sufficient familiarity with abandon ship procedures.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 September 2021
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 30 August 2021 Resolved
Crew did not display sufficient familiarity with firefighting procedures.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 September 2021
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 30 August 2021 Resolved
Fuel shutoff valves were not fully functional.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 September 2021
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 30 August 2021 Resolved
Vessel's paper charts date to 1985 and have not been updated. GPS was not updated.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 September 2021
Resolved 7 September 2021
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 30 August 2021 Resolved
Aspirin and eye wash in first aid kit is expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 September 2021
Resolved 7 September 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 August 2021 Resolved
Insufficient number of alcohol testing swabs were available onboard, alcohol testing swabs were expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 September 2021
Resolved 12 August 2022
Resolution: Resolved during the 2022 Annual Inspection.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 9 August 2021 Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel is overdue for annual inspection. Anniversary date is 09MAY.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 August 2021
Resolved 30 August 2021
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 16 October 2020 Resolved
Vessel's original current COI was not present onboard.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2020
Resolved 25 November 2020
Resolution: Sector KW provided signed replacement COI to vessel.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 13 October 2020 Resolved
Approved sail plan was not available on board.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2020
Resolved 25 November 2020
Resolution: Sector KW provided electronic copy of Sail Plan to the vessel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 October 2020 Resolved
01 crewmember is not listed on drug consortium, must be added prior to sailing with that crewmember.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 25 November 2020
Resolution: Vessel provided current certificate of compliance with all crew members enrolled.
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 13 October 2020 Resolved
Emergency broadcast placard was not posted.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2020
Resolved 25 November 2020
Resolution: Sector KW provided emergency broadcast placard to be posted at radio operating station.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 October 2020 Resolved
Child lifejackets were stowed together with adult lifejackets.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2020
Resolved 25 November 2020
Resolution: Lifejackets stowage is labeled, adult and children sizes are no longer stowed together.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 September 2020 Resolved
Through hull valves must be made available for inspection at drydock. Not all valves passing through the skin of the ship below the waterline were able to be verified to function properly. Make valves available for inspection to the satisfaction of the attending Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 September 2020
Resolved 6 October 2020
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 30 September 2020 Resolved
Provide Preventative Maintenance Plan for sail rigging in accordance with NVIC 02-16 to OCMI for review.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2020
Resolved 6 October 2020
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 30 September 2020 Resolved
Hatch cover for chain locker does not have a retention device to ensure the cover is not lost. Ensure cover is properly secured to vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2020
Resolved 6 October 2020
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 September 2020 Resolved
Vessel must be made available for drydock and internal structural examination in accordance with the Certificate of Inspection prior to the carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 September 2020
Resolved 30 September 2020
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 23 September 2019 Resolved
Replace gasket on Engine Room watertight deck hatch, gasket is dry rotted.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 October 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 23 September 2019 Resolved
Provide access to space forward of collision bulkhead, unable to open watertight hatch.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 October 2019
Resolution: Access gained, gasket needed on deck level.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 September 2019 Resolved
Permanently mount submersible bilge pump to hull in Engine Room.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 October 2019
Resolution: Pump mounted to hull
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 September 2019 Resolved
Provide portable hand bilge pump that is able to dewater each watertight compartment (Forward, Engine Room, and Lazarette).
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 October 2019
Resolution: Portable diaphragm pump provided and stored in middle compartment.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 23 September 2019 Resolved
Bilge high level visual indicators shall be readily visible at operating station, or provide visual relay at operating station with sign to indicate location of specific indication of compartments.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 October 2019
Resolution: Obstructions removed in front of high water alarms.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 September 2019 Resolved
Remove all dead-ended wires from vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 October 2019
Resolution: All dead-ended wires have been removed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 September 2019 Resolved
Generator starting batteries shall be provided with the following: securing straps, tray to contain electrolyte if spilled, protection to ungrounded terminals.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 October 2019
Resolution: Battery box provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 September 2019 Resolved
Main engine starting battery terminal connections shall be made with permanent connections, wing nut on grounded connection.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 October 2019
Resolution: Terminal nuts replaced with locking nuts.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 September 2019 Resolved
All cables and wire shall be installed with metal supports spaced no more than 24". Wires near forward A/C and battery box for starting motors found coiled and laying on deck.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 October 2019
Resolution: All electrical wires supported.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 23 September 2019 Resolved
Provide up to date paper copies of the following publications for the area of operation: US Coast Pilot [name withheld], Tide tables, Currents.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 October 2020
Resolution: All charts and publications were available.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 23 September 2019 Resolved
Provide FCC Safety Certificate of VHF radio installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 October 2019
Resolution: FCC safety certificate provided.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 23 September 2019 Resolved
Post all pages of Stability Letter at operating station
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 October 2020
Resolution: Original stability letter was posted.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 23 September 2019 Resolved
Provide PFD donning placard on main deck
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 October 2020
Resolution: PFD donning placard was posted.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 23 September 2019 Resolved
Relocate Child PFD's to an area that is unable to be locked, mark stowage location.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 October 2019
Resolution: PFD's locate din forward compartment.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 September 2019 Resolved
Vessels generator is restricted from use until it can be operationally tested to ensure fixed fire detection system will automatically shutdown generator upon activation.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 October 2020
Resolution: Generator was satisfactorily tested to automatically shutdown with fixed fire detection system.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 September 2019 Resolved
Replace Engine exhaust piping hangers, hangers were found melted. Hangers must be of a noncombustible material.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 October 2019
Resolution: Hangers replaced with metal straps.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 23 September 2019 Resolved
Provide installation dates for all rigging components listed in Appendix (1) to Enclosure (1) of NVIC 02-16.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 October 2019
Resolution: Completed, copy received.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 23 September 2019 Resolved
Make available a Rigging Preventative Maintenance Program that provides a level of detail commensurate with Appendix (2) to Enclosure (1) of NVIC 02-16 (Rigging Inventory/Preventative Maintenance Inspection Template (Sample)) or propose a mutually acceptable third party to survey the rigging and provide a report with a level of detailed commensurate with either Appendix (3) or (4) to Enclosure (1) of NVIC 02-16
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 October 2019
Resolution: PMP provided.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 23 September 2019 Resolved
Replace shackle on bob stay connection point to hull.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 October 2019
Resolution: Shackle replaced.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 23 September 2019 Resolved
Replace/repair rusted chain links on bob stay near hull connection point.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 October 2019
Resolution: Chain replaced
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 23 September 2019 Resolved
Conduct MOB and Fire drill in the presence of attending MI, weather was heavy at the time of inspection.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 September 2019
Resolution: Satisfactory MOB drill conducted.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 September 2019 Resolved
Provide manufactures manual for desired cooking equipment to be installed on board.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 October 2019
Resolution: Vessel will purchase MAGMA grills
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 September 2019 Resolved
Provide adequate waste receptacles constructed on noncombustible materials with no openings in side or bottom.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 October 2019
Resolution: Metal trashcan provided.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 September 2019 Resolved
Provide documentation for mattresses onboard that comply with either The U.S. Department of Commerce "Standard for Mattress Flammability" (FF 4-72.16) and do not contain polyurethane foam, or IMO Resolution A.688(17) and mattresses tested to that standard may contain polyurethane foam.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 January 2021
Resolution: Matresses will not be used until authorized ones are purchased.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 23 September 2019 Resolved
Mark all emergency exits (03) on both sides in 2-inch letters with “EMERGENCY EXIT, KEEP CLEAR”.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 October 2019
Resolution: All 3 exits marked on both sides
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 23 September 2019 Resolved
Remove securing devices on emergency exit hatches, hatches shall be readily available at all times and be capable of being opened from either side.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 October 2019
Resolution: Securing devices removed.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 23 September 2019 Resolved
Update safety procedures to include having passengers on voyages over 24hours don life jackets during orientation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 October 2020
Resolution: Safety procedures are updated.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 23 September 2019 Resolved
Provide direction to patrol watchmen during nighttime, direction shall include frequency of patrols, areas to patrol, what notice shall be given in the event of an emergency. Direction shall be posted at operating station.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 October 2020
Resolved 16 October 2020
Resolution: Watchmen directions are updated.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 17 September 2019 Resolved
Conduct/complete annual inspection, COI anniversary date listed on current COI is May 9th,2018. Annual inspection must have been completed within 3 months before or after of anniversary date between February 21st, 2019 and August 9th, 2019.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 September 2019
Resolution: Completed annual inspection.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 9 May 2018 Resolved
Pre-engineered fixed gas fire extinguishing system must have an audible and visible alarm that activates upon discharge. No audible or visible indication when only generator is operational and system is activated. Generator does shutdown when system is activated.
Action required: 705 - Other - as specified
Due 23 May 2018
Resolved 22 May 2018
Resolution: Proved proper shutdown of generator when fireboy is activated.
Communications › Public Address System › Loudspeaker
Issued 9 May 2018 Resolved
Vessel must be equipped with a general alarm system, portable public address system may be used if an unique sound can be produced to indicate an emergency. Passenger brief shall include this alarm for overnight guests.
Action required: 705 - Other - as specified
Due 23 May 2018
Resolved 23 July 2018
Resolution: VERIFIED SYSTEM IS FUNCTIONAL
Communications › Radio Communications › VHF Radiotelephone
Issued 9 May 2018 Resolved
Provide GPS input for VHF radio.
Action required: 705 - Other - as specified
Due 23 May 2018
Resolved 23 July 2018
Resolution: VHS HAS GPS INPUT
Documentation › Markings/Placards › Warning Signs
Issued 9 May 2018 Resolved
Relabel/mark forward emergency exit.
Action required: 705 - Other - as specified
Due 23 May 2018
Resolved 23 July 2018
Resolution: EMERGENCY EXIT LABELED
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 9 May 2018 Resolved
Mark vessel name on STBD bow.
Action required: 705 - Other - as specified
Due 23 May 2018
Resolved 22 May 2018
Resolution: Name marked on STBD bow.
Communications › Radio Communications › EPIRB
Issued 9 May 2018 Resolved
Replace hydrostatic release for EPIRB installation so EPIRB will float free.
Action required: 705 - Other - as specified
Due 23 May 2018
Resolved 22 May 2018
Resolution: New hydrostatic release installed.
Electrical › Lighting (emergency) › Switch
Issued 9 May 2018 Resolved
Emergency lighting must be fitted along the line of escape to the main deck from all passenger and crew accommodation spaces. Lighting must automatically actuate upon loss of normal power. If not equipped with a single source of emergency power for lighting, the lighting must have individual batteries that: activate upon loss of normal power, be permanently installed, connected to a automatic battery charger and have capacity for a minimum of 2 hours of continuous operation.
Action required: 705 - Other - as specified
Due 29 June 2018
Resolved 23 July 2018
Resolution: 03 EMERGENCY LIGHTS ACTIVATED UPON SHUTTING DOWN OF DC POWER
Communications › Radio Communications › VHF Radiotelephone
Issued 15 May 2017 Resolved
VHF Radio did not have GPS input as required for DSC.
Action required: 705 - Other - as specified
Due 19 June 2017
Resolved 18 August 2017
Construction/Loadline › Hull › Side Shell
Issued 24 March 2017 Resolved
Conduct survey of vessel bottom due to collision with another vessel to satisfaction of attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 March 2017
Resolution: Hired diver took underwater footage of vessels hull, only paint scrapes were found on port side hull.
Construction/Loadline › Hull › Side Shell
Issued 24 March 2017 Resolved
Crop and renew inset in hull on port side below chine.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 April 2017
Resolution: Insert completed.
Lifesaving › Lifebuoys › Serviceable
Issued 15 August 2016 Resolved
Replace port and starboard lifebuoys prior to carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 September 2016
Resolution: Lifebouys replaced, re-stenciled and put into service.
Lifesaving › Lifefloat › Serviceable
Issued 15 August 2016 Resolved
Repair/Renew port and starboard life floats, vessel restricted to 3NM until completed.
Action required: 705 - Other - as specified
Due 15 September 2016
Resolved 26 August 2016
Resolution: Lifefloats removed from vessel and amended route on COI.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 15 August 2016 Resolved
Replace/Renew life ring light, vessel restricted to daylight operations until completed.
Action required: 705 - Other - as specified
Due 15 September 2016
Resolved 3 September 2016
Resolution: New light put into service and attached to lifebouy.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 15 August 2016 Resolved
Contents of first aid kit expired, replace expired contents.
Action required: 705 - Other - as specified
Due 15 September 2016
Resolved 3 October 2016
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 15 August 2016 Resolved
Rail courses exceed 4 inches, submit plans for approval prior to conducting repairs.
Action required: 705 - Other - as specified
Due 15 September 2016
Resolved 15 September 2016
Resolution: Owner submitted plans for adding 4" rail courses. See attached plans.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 15 August 2016 Resolved
Post all pages of most recent COI and Stability letter.
Action required: 705 - Other - as specified
Due 15 September 2016
Resolved 15 September 2016
Resolution: COI and Stability Letter properly mounted in near operating station.
Personnel › Certificates/Documents/Licenses › Certificate, CPR Course Completion
Issued 15 August 2016 Resolved
Crew needs CPR training.
Action required: 705 - Other - as specified
Due 15 September 2016
Resolved 3 October 2016
Documentation › Manuals/Policy Documentation › Instructions for On-board Maintenance (lifesaving)
Issued 15 August 2016 Resolved
Maintain logs for crew training, emergency training and life saving maintenance.
Action required: 705 - Other - as specified
Due 15 September 2016
Resolved 3 October 2016
Operations/Management › Drills/Instruction › Launching/Recovery of Survival Craft
Issued 15 August 2016 Resolved
Post emergency instructions.
Action required: 705 - Other - as specified
Due 15 September 2016
Resolved 3 October 2016
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 15 August 2016 Resolved
Clearly mark stowage space of PFD's.
Action required: 705 - Other - as specified
Due 15 September 2016
Resolved 15 September 2016
Resolution: PFD's removed from cabin closet, stored in plain sight in cabin.
Fire Fighting › Fire Bucket › Quantity
Issued 15 August 2016 Resolved
Vessel missing fire bucket and all buckets need to be properly marked.
Action required: 705 - Other - as specified
Due 15 September 2016
Resolved 15 September 2016
Resolution: 03 Buckets put into service and stenciled.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 15 August 2016 Resolved
Operator needs to present FCC operator permit to marine inspector.
Action required: 705 - Other - as specified
Due 15 September 2016
Resolved 18 October 2016
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 15 August 2016 Resolved
Provide rigging inspection program to include all standing and running rigging.
Action required: 705 - Other - as specified
Due 15 September 2016
Resolved 3 October 2016
Personnel › Certificates/Documents/Licenses › License, GMDSS Radio Operator
Issued 5 October 2015 Resolved
Provide operator with a Marine Radio Operator Permit.
Action required: 705 - Other - as specified
Due 9 October 2015
Resolved 28 November 2016
Resolution: Cleared during annual inspection
Documentation › Certificates/Documents › FCC SSL
Issued 5 October 2015 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 9 October 2015
Resolved 9 October 2015
Operations/Management › Drug and Alcohol Testing › Testing, Random
Issued 5 October 2015 Resolved
Provide complete USCG Drug Testing Program.
Action required: 705 - Other - as specified
Due 9 October 2015
Resolved 9 October 2015
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 5 October 2015 Resolved
Log training, drills, and lifesaving equipment testing/maintenance.
Action required: 705 - Other - as specified
Due 9 October 2015
Resolved 28 November 2016
Resolution: Closed during annual inspection
Communications › Alarms/Indicators › High Water Alarm
Issued 5 October 2015 Resolved
Mount lazarette high water alarm.
Action required: 705 - Other - as specified
Due 9 October 2015
Resolved 9 October 2015
Engineering › Steering Gear System › Rudder Stock
Issued 5 October 2015 Resolved
Make emergency steering operable.
Action required: 705 - Other - as specified
Due 9 October 2015
Resolved 9 October 2015
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 5 October 2015 Resolved
Properly label all life preserver locations.
Action required: 705 - Other - as specified
Due 9 October 2015
Resolved 28 November 2016
Resolution: Closed during annual inspection
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 5 October 2015 Resolved
Service all fire extinguishing equipment.
Action required: 705 - Other - as specified
Due 9 October 2016
Resolved 9 October 2015
Lifesaving › Lifefloat › Float-free Link
Issued 1 October 2014 Resolved
Provide appropriate weak link for starboard life float.
Action required: 705 - Other - as specified
Due 17 October 2014
Resolved 11 December 2014
Engineering › Bilge Water Management System › Hose
Issued 1 October 2014 Resolved
Remove excess 12 volt bilge pump discharge hoses from the machinery space bilge pump system.
Action required: 705 - Other - as specified
Due 17 October 2014
Resolved 11 December 2014
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 1 October 2014 Resolved
Label remainder of Adult PFD storage locations.
Due 17 October 2014
Resolved 12 December 2014
Documentation › Certificates/Documents › Certificate of Inspection
Issued 1 October 2014 Resolved
Post all pages of the Certificate of Inspection.
Action required: 705 - Other - as specified
Due 17 October 2014
Resolved 11 December 2014
Documentation › Certificates/Documents › Stability Letter
Issued 1 October 2014 Resolved
Post all pages of the Stability Letter.
Action required: 705 - Other - as specified
Due 17 October 2014
Resolved 11 December 2014
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 1 October 2014 Resolved
Update and post emergency instructions.
Action required: 705 - Other - as specified
Due 17 October 2014
Resolved 11 December 2014
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 1 October 2014 Resolved
Provide closure devices for machinery space vent openings. Closures should be vapor tight. I recommend non-combustible closure devices. Closure devices must be readily available and mounted near the vicinity of the vent.
Action required: 705 - Other - as specified
Due 17 October 2014
Resolved 12 December 2014
Communications › Radio Communications › EPIRB
Issued 1 October 2014 Resolved
Register EPIRB with NOAA and replace expired hydrostatic release.
Action required: 705 - Other - as specified
Due 17 October 2014
Resolved 11 December 2014
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 6 January 2012 Resolved
Provide proof of servicing for all fire fighting equipment.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2012
Resolution: All equipment was checked for servicing tags; all sat. Fireboy was tested; main engine and generator shutdown properly and override switch was tested as well, all sat.
Engineering › Bilge Water Management System › Pump
Issued 6 January 2012 Resolved
Provide proper operation of all bilge pumps.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2012
Resolution: Vessel has three electric submersible pumps; one located amidship in the accomodation space, one in the engine room, and one in the master''s cabin (smaller pump that is plumbed directly to the master''s sink drain. Two main spaces tested sat.
Communications › Radio Communications › EPIRB
Issued 6 January 2012 Resolved
Provide proof of EPIRB NOAA registration.
Due 20 January 2012
Resolved 7 May 2012
Resolution: Vessel owner provided an updated EPIRB registration form.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 16 November 2010 Resolved
Generator in machinery space does not automatically shut down with activation of Fireboy. Do not use generator with passengers onboard until automatic shut down is installed IAW 46CFR 181.420 (a) (3) within 14 days from date of inspection.
Due 30 November 2010
Resolved 30 November 2010
Resolution: Generator installed with automatic shutdown. Proved proper operation.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 16 November 2010 Resolved
Provide proof of servicing for all portable fire extinguishers and pre-engineered fixed firefighting system IAW 46CFR 176.810 within 14 day from date of inspection.
Due 30 November 2010
Resolved 30 November 2010
Resolution: Portable fire extinguishers and pre-engineered fixed fire fighting system were serviced IAW 46CFR 176.810.
Lifesaving › Lifefloat › Serviceable
Issued 16 November 2010 Resolved
Life float is damaged. Repair or replace IAW 46CFR 185.700 within 14 days from date of inspection. Limited to 30 total persons.
Due 30 November 2010
Resolved 30 November 2010
Resolution: Owner repaired life float with [name withheld] repair kit.
Engineering › Fuel Oil Service System › Piping
Issued 7 January 2010 Resolved
Provide flame shield bowl under fuel filter IAW 46 CFR 182.455 within 30 days.
Action required: 705 - Other - as specified
Due 11 February 2010
Resolved 15 January 2010
Resolution: Fuel filter flame shield installed. Received proof of installation via email picture to the satisfaction of the CG Marine Inspector.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.