MAURY USCG vessel records
← All vessels

YUNQUE PRINCESS

YUNQUE PRINCESS is a 2006 passenger vessel (inspected). The Coast Guard has recorded 16 inspections since 2016, most recently in September 2025, along with 34 deficiencies — 1 with no resolution recorded —, 3 operational controls and 3 casualty investigations between 2006 and 2017.

Records from 2006 to 2025. Most recent: inspection, 16 September 2025.

Built
2006
Last inspected
16 September 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 16 September 2025
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 7 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDP4817
855726
Flag
UNITED STATES
Maury page id
psix-855726

Documentation record

Registered dimensions (L × B × D)66.6 ft × 28.0 ft × 9.2 ft
Registered tonnagegross 75 / net 51
ITC dimensions (L × B × D)66.6 ft × 28.0 ft × 9.2 ft
ITC tonnageNot recorded
BuilderKVICHAK MARINE INDUSTRIES · SEATTLE, WA, UNITED STATES · built 2006
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portFAJARDO, PR
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 1 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it75 - Regulatory (Subpart C or D), Gross Ton
51 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 16

16 September 2025 Internal Structural Exam · Hull Examination · Drydock Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8234981
17 June 2025 Deficiency Check · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8160123
3 February 2025 Administrative Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8074146
11 August 2024 Deficiency Check · Damage Survey
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7979362
19 March 2024 Deficiency Check · COI Inspection · DAPI Audit
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7872553
6 December 2023 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7834654
25 August 2023 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7776773
12 October 2022 Internal Structural Exam · Damage Survey
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7576002
11 February 2022 Internal Structural Exam · Hull Examination
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7394732
15 November 2019 Drydock Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6856180
6 October 2017 Damage Survey
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6284300
20 September 2017 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6290924
3 March 2017 Annual Inspection · Examination of Repairs · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6098460
23 November 2016 Drydock Exam · Internal Structural Exam · Hull Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6046719
29 September 2016 Administrative Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6012138
14 March 2016 Deficiency Check · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5849393

Deficiency record · 34

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 October 2025 No resolution recorded
Portside shaft tunnel was found with 25% wastage during YR2025 dry dock. Shaft tunnel shall be replaced at the next dry dock in YR2027. Code 705 This deficiency shall be cleared prior dry dock in YR2027.
Action required: 705 - Other - as specified
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 17 June 2025 Resolved
Each opening in a watertight bulkhead must have a means to close it watertight. The following watertight bulkheads in number 2 void starboard side were found to have penetrations: a. bulkhead between the collision and void 2 with 1 hole in the outer side of the bulkhead due to incomplete weld. b. Bulkhead in void 2 forward of the fuel tanks with 02 holes due to incomplete weld. Provide a temporary means to cover the penetrations until next dry dock in September 2025. 46 CFR 171.111
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 June 2025
Resolution: A temporary epoxy based compund was applied until permanent repair is connudcted during next dry dock.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 17 June 2025 Resolved
Each opening in a watertight bulkhead must have a means to close it watertight. The following watertight bulkheads in number 2 void starboard side were found to have penetrations: a. bulkhead between the collision and void 2 with 1 hole in the outer side of the bulkhead due to incomplete weld. b. Bulkhead in void 2 forward of the fuel tanks with 02 holes due to incomplete weld. Conduct permanent repairs during next dry dock credit in September 2025. 46 CFR 171.111 and 46 CFR 176.600 (d) Code 705
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 September 2025
Resolved 22 October 2025
Resolution: Insert was welded.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 17 June 2025 Resolved
Electrical equipment on a vessel must be installed and maintained to:(a) Provide services necessary for safety under normal and emergency conditions;(b) Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock;(c) Minimize accidental personnel contact with energized parts; and (d) Prevent electrical ignition of flammable vapors. Dead-end electrical wiring was found under the operating station. 46 CFR 183.200.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2025
Resolved 30 June 2025
Resolution: Corrected.
01 - Certificates & Documentation › 012 - Crew Certificates › Evidence of Basic Training
Issued 17 June 2025 Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI. (2) All alcohol testing devices used to meet the requirements of this part must be currently listed on either the Conforming Products List (CPL) titled “Modal Specifications for Devices To Measure Breath Alcohol” or “Conforming Products List of Screening Devices To Measure Alcohol in Bodily Fluids,” which are published periodically in the Federal Register by National Highway Traffic Safety Administration (NHTSA). Alcohol testing swabs date was found expired. 46 CFR 4.06-15, code 16C.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2025
Resolved 30 June 2025
Resolution: An alcohol breathalized BAC approved by DOT was purchased and placed on board, and 20 strips where also purchased.
01 - Certificates & Documentation › 012 - Crew Certificates › Evidence of Basic Training
Issued 17 June 2025 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2025
Resolved 30 June 2025
Resolution: Training provided and posted placard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 February 2025 Resolved
This part contains requirements for the design, construction, installation, and operation of propulsion and auxiliary machinery, piping and pressure systems, steering apparatus, and associated safety systems. Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Received loss of propulsion on port engine due to the sea chest valve being secured causing the engine to overheat. Conduct sea trials to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 February 2025
Resolved 4 February 2025
Resolution: Conducted Sat sea trials.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 August 2024 Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Vessel experienced fire in Port Engine Room. Pre-engineered fire extinguishing system deployed extinguishing the fire. Portable extinguishers were used after the pre-engineered system completed deploying to ensure fire was extinguished. Vessel may not conduct repairs until Marine Inspector attends the vessel and assesses damages. Repairs will require repair proposal. Vessel may not operate until found satisfactory by the attending Marine Inspector.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 August 2024
Resolution: Turbo, oil supply line, oil return line, coolant line and exhaust manifold was replaced. Oil on lagging and equipment was cleaned. Sea trial conducted at normal operating RPM's. Repairs found satisfactory by attending Marine Inspectors.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 August 2024 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Crank Case Breather hoses broken. Repairs will require repair proposal. Vessel may not operate until found satisfactory by the attending Marine Inspector.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 August 2024
Resolution: Crank case breathers were repaired and hose routed to the bilge. Repair found satisfactory by attending Marine Inspector.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 August 2024 Resolved
Connections and terminations to all conductors must retain the original electrical, mechanical, flame-retarding, and, where necessary, fire-resisting properties of the cable. All connecting devices must be suitable for copper stranded conductors. The connections must be made within an enclosure and the insulated cap of the connector must be secured. Dead end wires found
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 August 2024
Resolved 30 August 2024
Resolution: Dead end wires secured and found satisfactory by the attending Marine Inspector.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 19 March 2024 Resolved
A durable placard must be posted next to all radiotelephone installations with the emergency broadcast instructions and information, specific to the individual vessel. The emergency broadcast placard was for a Fishing Vessel. No vessel name was on the placard.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 19 March 2024
Resolved 21 March 2024
Resolution: Correct placard installed. Vessel rep provided picture of laminated placard.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 19 March 2024 Resolved
The following vessels must have on board a properly installed, operational Coast Guard type-approved AIS. A self-propelled vessel of 65 feet or more in length, engaged in commercial service. The vessel's length is 66.6 feet in length. Install an AIS Class A device required by 33 CFR 164-46(b)(1) or Class B device required by33 CFR 164.46(b)(2).
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 March 2024
Resolved 26 March 2024
Resolution: A Gramin AIS 800 unit was installed Class A. Received text message with attached photos showing the AIS setup screen was correctly programed and AIS tracking a target while moored to the dock.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 March 2024 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. The first aid kit was missing: a. 6 each burn prep - 10c b. 3 each compress bandages - 10c c. 1 each triangle bandage - 10c d. Instructions - outstanding
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 April 2024
Resolved 21 March 2024
Resolution: Vessel rep provided a photo of an American Red Cross First Aid Guide that was placed in the first aid kit..
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 March 2024 Resolved
The emergency instructions must be designed to address the particular equipment, arrangement, and operation of each individual vessel. During the man overboard drill a crew member tending the safety line for the crew member at the bottom of the recovery platform was observed not wearing a lifejacket nor tethered to the vessel, this presents an unsafe operation that is not addressed by the Emergency Instructions.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 19 March 2024
Resolved 20 March 2024
Resolution: Emergency instructions amended to require all deckhand involved in man over board to wear lifejackets.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 October 2022 Resolved
Check Port and STBD shafts for roundness and proper alignment.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 January 2024
Resolution: SAT tests were conducted
Lifesaving › Lifefloat › Painter
Issued 8 March 2017 Resolved
Connect each life float to painter connected to weak ling connected to vessel
Action required: 705 - Other - as specified
Due 24 March 2017
Resolved 9 March 2017
Lifesaving › Lifefloat › Markings
Issued 8 March 2017 Resolved
Replace label/name/passenger count on life floats
Action required: 705 - Other - as specified
Due 24 March 2017
Resolved 27 March 2017
Lifesaving › Lifefloat › Platform
Issued 8 March 2017 Resolved
Remove extra equipment from life floats.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 March 2017
Resolved 9 March 2017
Electrical › Lighting (service) › Lighting Fixture
Issued 8 March 2017 Resolved
Replace broken light covers and bulbs throughout.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 March 2017
Resolved 27 March 2017
Operations/Management › Passenger Operations › Safety Orientation
Issued 8 March 2017 Resolved
Label max pax for second deck on fwd steps
Action required: 705 - Other - as specified
Due 24 March 2017
Resolved 27 March 2017
Documentation › Certificates/Documents › Certificate of Inspection
Issued 8 March 2017 Resolved
Post all pages of the COI at the operating station
Action required: 705 - Other - as specified
Due 24 March 2017
Resolved 9 March 2017
Documentation › Certificates/Documents › Stability Letter
Issued 8 March 2017 Resolved
Post all pages of the stability letter at the operating station.
Action required: 705 - Other - as specified
Due 24 March 2017
Resolved 9 March 2017
Operations/Management › Drills/Instruction › Not Conducted
Issued 8 March 2017 Resolved
Post Current DAPI sticker
Action required: 705 - Other - as specified
Due 24 March 2017
Resolved 9 March 2017
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 8 March 2017 Resolved
Replace bad reflective tape on PFDs
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 March 2017
Resolved 27 March 2017
Lifesaving › Lifefloat › Retroreflective Material
Issued 8 March 2017 Resolved
Replace bad reflectice tape on life floats
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 March 2017
Resolved 27 March 2017
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 8 March 2017 Resolved
Replace reflective tape on aft lifering
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 March 2017
Resolved 27 March 2017
Engineering › Steering Gear System › Rudder
Issued 8 March 2017 Resolved
Prove proper operation of both rudders. The STBD rudder is not working.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 March 2017
Resolved 9 March 2017
Resolution: Performed sea trials to prove proper operation of the rudder.
Fire Fighting › Fire Pumps › Pressure
Issued 14 March 2016 Resolved
Prove proper operation of fire pump.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 March 2016
Resolved 25 March 2016
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 14 March 2016 Resolved
Provide 11 additional lifejackets. Vessel will be reduced to 142 total persons on board until lifejackets are made available.
Condition: Invalid
Action required: 705 - Other - as specified
Due 28 March 2016
Resolved 25 March 2016
Engineering › Steering Gear System › Hydraulic Hose
Issued 14 March 2016 Resolved
Renew hydraulic steering gear hose on port side actuator.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 March 2016
Resolved 25 March 2016
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 March 2016 Resolved
Replace wire connectors with approved type on distribution panel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 March 2016
Resolved 25 March 2016
Electrical › Lighting (service) › Lighting Fixture
Issued 14 March 2016 Resolved
Provide guard covers for all lighting fixtures.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 March 2016
Resolved 25 March 2016
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 14 March 2016 Resolved
Pre-engineered fixed gas fire extinguishing system must automatically shut down generator located in starboard engine space.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 March 2016
Resolved 25 March 2016
Operations/Management › Vessel Activity › Loading
Issued 14 March 2016 Resolved
Renew Safety Wire for Loading Ramp.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 March 2016
Resolved 25 March 2016

Casualty record · 3

30 December 2006Routine · role: Involved in a Marine Casualty · activity 2852123
4 October 2011Routine · role: Involved in a Marine Casualty · activity 4176309
20 September 2017Routine · role: Involved in a Marine Casualty · activity 6290924
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.