Records from 2016 to 2025. Most recent: inspection, 27 August 2025.
Inspection history · 15
27 August 2025
Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8205571
20 May 2025
Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8116137
9 May 2024
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7909135
16 October 2023
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7806776
21 August 2023
Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7773278
2 November 2022
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7589333
19 August 2021
Drydock Exam · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7292048
22 August 2019
Internal Structural Exam · Administrative Inspection · COI Inspection · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6791350
9 November 2018
Damage Survey · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6578384
19 October 2018
Damage Survey · Administrative Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6566713
14 March 2018
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6368967
19 January 2018
Hull Examination · Deficiency Check · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6338430
13 March 2017
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6100463
23 May 2016
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5882138
13 April 2016
Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5847140
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 May 2024
Resolved
Vessel is required to carry a minimum of one 40-B:C portable fire extinguisher in vicinity of the machinery space. No 40-B:C fire extinguisher was on board. Outfit vessel with required number of portable fire extinguishers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 May 2024
Resolution: New 40 b:c fire ext placed on board
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 May 2024
Resolved
Vessel must carry one floating waterlight approved IAW 46CFR161.010. Waterlight was installed with wrong battery type. Replace battery with approved type.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2024
Resolved 16 May 2024
Resolution: New battery installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 9 May 2024
Resolved
Gauges to indicate lubricating oil pressure must be provided for all propulsion engines installed in the vessel and must be readily visible at the operating station. Oil pressure gauge not functioning. Repair guage.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2024
Resolved 16 May 2024
Resolution: Eng gauges funtioning properly
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 9 May 2024
Resolved
Vessel must be equipped with at least two operable portable battery lights located at the operating station and at the access to the propulsion machinery space. No functioning flashlights onboard. Outfit vessel with required portable battery lights.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2024
Resolved 16 May 2024
Resolution: Portable lights placed onboard
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 9 November 2018
Resolved
The vessel sustained various damage to the hull and structures as a result of hurricane Michael. Provide repair plan to MSD Panama City for review and approval.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 August 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 November 2018
Resolved
Due to the nature of the damage and inabilityto inspect the bottom of the pontoons, the vessel must be dry-docked for a complete inspection.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 August 2019
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 19 January 2018
Resolved
Repair 2 fiberglass cracks on seat mounting surface
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 February 2018
Resolved 14 March 2018
Resolution: repair conducted
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 19 January 2018
Resolved
Repair 2 weld fracture on aft step and properly secure step access
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 February 2018
Resolved 14 March 2018
Resolution: repair conducted
Construction/Loadline › Hull › Hull Plating
Issued 19 January 2018
Resolved
Repair identified 3 fiberglass cracks on inner pontoon hull
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 February 2018
Resolved 14 March 2018
Resolution: repair conducted
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 19 January 2018
Resolved
Properly wire aft all around light. Vessel is restricted to daylight operation only
Action required: 705 - Other - as specified
Due 2 February 2018
Resolved 14 March 2018
Resolution: repair conducted
Electrical › Electric Generation Source (service) › Panelboard
Issued 19 January 2018
Resolved
Properly connect wires under console to a terminal strip.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 February 2018
Resolved 14 March 2018
Resolution: repair conducted
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 19 January 2018
Resolved
Tighten loose screw in canopy mounting surface stbd side mid ship
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 February 2018
Resolved 14 March 2018
Resolution: repairs conducted.