MAURY USCG vessel records
← All vessels

ZIM QINGDAO

ZIM QINGDAO is a 2006 freight ship. The Coast Guard has recorded 35 inspections since 2017, most recently in July 2023, along with 6 deficiencies and 6 operational controls.

Records from 2017 to 2023. Most recent: inspection, 30 July 2023.

Built
2006
Last inspected
30 July 2023
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 30 July 2023
…with no type recorded9
Operational controls None recorded without a removal date
Years with a record 7 calendar years (2017–2023)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9318163
856046
Flag
ISRAEL
Maury page id
psix-856046

Documentation record

Tonnage as PSIX records it39906 - Convention (Subpart B), Gross Ton
24504 - Convention (Subpart B), Net Ton
50729 - Dead Weight, Ton
67510 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 35

30 July 2023 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7755740
30 March 2023 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7659580
23 March 2023 In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7655459
23 March 2023 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7655771
22 March 2023 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7654566
12 September 2022 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7556784
26 October 2021 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7340074
5 June 2021 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7216071
12 April 2021 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7173422
11 April 2021 PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7172769
19 February 2021 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7142764
21 December 2020 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7114618
26 October 2020 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7084246
27 August 2020 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7043712
26 August 2020 PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7043031
22 August 2020 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7039834
2 July 2020 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6993253
24 June 2020 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6985459
6 May 2020 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6949334
2 May 2020 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6947187
27 September 2019 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6822391
20 September 2019 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6816481
4 August 2019 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6771907
28 July 2019 ISPS II Exam · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6763025
26 October 2018 ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6568599
2 September 2018 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6529575
28 August 2018 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6525381
13 July 2018 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6477567
12 July 2018 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6476382
24 May 2018 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6422546
9 January 2018 Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6334608
21 June 2017 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6182644
3 May 2017 Ballast Water Examination · In-Service Inspection · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6137775
3 May 2017 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6142024
23 January 2017 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6075061

Deficiency record · 6

15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 23 March 2023 Resolved
In meeting these requirements, the company should ensure that inspections are held at appropriate intervals. Vessel experienced fuel piping rupture in cargo hold number 6. Vessel SMS requires visual inspections of cargo holds every three months. Crew could not produce records of having conducted this inspection. ISM CODE 10.2.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 March 2023
Resolution: 24MAR23: Vessel provided satisfactory proof to the Coast Guard that shows the visual inspection required as per vessel's SMS of the cargo hold every three month is beeing carried out and has been logged.
01 - Certificates & Documentation › 011 - Ships Certificates › International Oil Pollution Prevention (IOPP)
Issued 22 March 2023 Resolved
...Every other ship of 400 gross tonnage and above shall be subject to the surveys specified below…an annual survey within three months before or after each anniversary date of this certificate. Anniversary date of IOPP is 30 August 2026. Certificate was improperly endorsed during special survey on 14 February 2023. MARPOL(17con) I/6.4
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 April 2023
Resolved 30 March 2023
Resolution: Administration reissued certificate and removed the endorsement that was added in error.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 22 March 2023 Resolved
Guard rails fitted on superstructure and freeboard decks shall have at least three courses. Bay 23 port side top railing was found detached from stantion and had excessive wasting. 66 ICLL 25.3
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 22 March 2023
Resolved 22 March 2023
Resolution: Crew fitted a temporary repair on railing to the satisfaction of Coast Guard until full maintenance and repair can take place.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 22 March 2023 Resolved
Where the contents and use of a space are such that there is doubt as to its classification for the purpose of this regulation…it shall be treated as a space within the relevant category having the most stringent boundary requirements. Flammable liquids found stored in unapproved container within engine room. 74 SOLAS (20 con) II-2/9.2.3.3.2.2.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 22 March 2023
Resolved 22 March 2023
Resolution: Crew removed flammable liquids from engine room space and into paint locker to the satisfaction of the Coast Guard.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 22 March 2023 Resolved
Stairways and lift trunks which penetrate more than a single deck shall be surrounded by at least “A-0” class divisions and be protected by self-closing doors at all levels. Two out of three doors in escape trunk from engine room railed to properly close. 74 SOLAS (20 con) II-2/9.2.3.4.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 22 March 2023
Resolved 22 March 2023
Resolution: Crew repaired doors to close properly.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 3 May 2017 Resolved
DOOR REQUIRED TO BE SELF CLOSING SHALL NOT BE FITTED WITH HOLD BACK HOOKS. PURIFIER ROOM IN ENGINE ROO HAD 02 DOORS WITH HOLDBACK HOOKS. (CLOTH AND FIREHOSE USED)
Action required: 705 - Other - as specified
Due 3 May 2017
Resolved 3 May 2017
Resolution: DEFICIENCY RECTIFIED ON THE SPOT

Ownership record