MAURY USCG vessel records Sign in
← All vessels

YC AZALEA

YC AZALEA is a 2004 tank ship. The Coast Guard has recorded 13 inspections since 2006, most recently in April 2025, along with 6 deficiencies and 2 operational controls.

Records from 2006 to 2025. Most recent: inspection, 15 April 2025.

Built
2004
Last inspected
15 April 2025
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9272682 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
856075
Flag
REPUBLIC OF KOREA
—
Maury page id
psix-856075

Inspections, by type

…with no type recorded5
Years with a record 8 calendar years (2006–2025)
The 13 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it12105 - Convention (Subpart B), Gross Ton
6352 - Convention (Subpart B), Net Ton
25511 - Displacement, Ton
19997 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 13

15 April 2025 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8112343
20 February 2025 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8082111
9 February 2025 Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8076898
16 November 2024 PSC B · COC-CHEM & TVE Renew
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8035549
24 January 2017 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6078680
9 August 2016 COC-CHEM & TVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5967183
10 August 2015 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5211693
27 August 2014 Construction Oversight · Deficiency Check · Damage Survey
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4966425
15 August 2014 Type not recorded
No type recorded · USCG WMSL Crew Charlie - Alameda · Activity 4958559
11 July 2008 MARPOL Annex I Examination · ISPS II Exam · Ballast Water Examination · COC-CHEM Renew · MARPOL Annex V Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3264495
23 September 2006 ISPS II Exam · Ballast Water Examination · COC-CHEM Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2784070
23 September 2006 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2785105
20 September 2006 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2783367

Deficiency record · 6

07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 16 November 2024 Resolved
The inert gas system shall be capable of inerting, purging, and gas-freeing empty tanks and maintaining the atmosphere in cargo tanks with the required oxygen contact; delivering IG with an oxygen content of no more than 5% by volume to the cargo tanks. PSCO observed IG System to be inoperable. Thus unable to provide required IG for flammable cargos. 74 SOLAS (20) II-2/4.5.5.3.1 / FSS Code Chapter 15.2.2.1.2.5
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 15 April 2025
Resolution: Received Class Report stating Nitrogen bottles were installed to replace the inoperable IG system. Def Cleared.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 November 2024 Resolved
All components in the transfer system are leak free except that a component in the transfer system, such as the packing glands of a pump may leak at a rate that does not exceed a capacity of the discharge containment provided during the transfer operation. PSCO Observed temporary repair to the NO.1 Bunkering Line. 33 CFR 156.120(p)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 21 January 2025
Resolution: PSC NOLA received a class report from Korean Register satisfying the requirement.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Quantity of CO2
Issued 27 August 2014 Resolved
0725 Machinery spaces of category A containing internal combustion machinery shall be provided with a fixed fire fighting system. Vessel reported fire in machinery repair shop and a subsequent release of the CO2 Fixed Fire Extinguishing System. SOLAS 09 CH11-2 REG 10 5.2.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 September 2014
Resolution: Repaired and corrected to the satisfaction of the attending Classification Representative.
Documentation › Certificates/Documents › IOPP Certificate
Issued 27 August 2014 Resolved
0150 An International Oil Pollution Prevention Certificate shall be issued for a period specified by the administration, which shall not exceed five years. Current IOPP Certificate has expired. MARPOL ANNEX 1REG 10 (1)
Action required: 705 - Other - as specified
Due 27 August 2014
Resolved 27 August 2014
Resolution: IOPP Certificate was validated.
Electrical › Electric Supply System (service) › Cable
Issued 27 August 2014 Resolved
0750: Where cables which are installed in hazardous areas introduce the risk of fire or explosion in the event of an electrical fault in such areas, special precautions against such risks shall be taken to the satisfaction of the Administration. Additionally, cables and wiring shall be installed and supported in such a manner as to avoid chafing or other damage. Cables and wiring...view narrative.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 September 2014
Resolution: Repaired and corrected to the satisfaction of the attending Classification Representative.
Electrical › Electric Generation Source (emergency) › Generator
Issued 27 August 2014 Resolved
1499 The electrical power available shall be sufficient to supply all those services that are essential for safety in an emergency, due regard being paid to such services as may have to be operated simultaneously. The ship's Emergency Generator is currently out of service needing a replacement of the voltage regulator and specific fuses. SOLAS 04 CH 11-1 REG 43 (2)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 September 2014
Resolution: Repaired and corrected to the satisfaction of the attending Classification Representative.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.