MAURY USCG vessel records Sign in
← All vessels

KNOTTS ISLAND

KNOTTS ISLAND is a 1962 passenger vessel (inspected). The Coast Guard has recorded 68 inspections since 1987, most recently in July 2023, along with 62 deficiencies — 2 with no resolution recorded — and 1 casualty investigation in 2018.

Records from 1987 to 2023. Most recent: inspection, 13 July 2023.

Built
1962
Last inspected
13 July 2023
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDJ4550
Flag
UNITED STATES
367778770
Maury page id
psix-85691

Inspections, by type

…with no type recorded8
…past their stated due date2
Years with a record 30 calendar years (1987–2023)
The 68 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)66.8 ft × 28.0 ft × 6.6 ft
Registered tonnagegross 99 / net 54
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
Builderbuilder not recorded · WILMINGTON, DE, UNITED STATES · built 1962
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portHULL, MA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 17 August 2026 · expires 31 August 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it99 - Regulatory (Subpart C or D), Gross Ton
54 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDJ4550MMSI 367778770 · active · compulsorily equipped · granted 23 March 2017, expires 23 March 2027
WTQ5176MMSI 367165770 · expired · compulsorily equipped · granted 9 February 2007, cancelled 1 July 2017
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 68

13 July 2023 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7741634
1 December 2020 Deficiency Check · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7101459
22 October 2020 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7093098
15 September 2020 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7058490
25 July 2019 Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6760791
11 September 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6538019
24 July 2018 Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6489354
11 June 2018 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6442252
4 June 2018 Damage Survey · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6435570
8 May 2017 COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6141107
28 June 2016 Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5922155
6 May 2016 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5870486
31 March 2016 Drydock Extension · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5844455
28 September 2010 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3858730
24 March 2010 Drydock Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3702757
26 March 2009 Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3440349
22 April 2008 Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3189870
6 March 2008 Hull Examination · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3159590
18 April 2007 COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2923926
11 April 2006 Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2621784
7 March 2006 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2597550
27 April 2005 Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2343850
16 April 2004 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2045163
27 February 2004 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2014195
15 April 2003 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1869465
22 April 2002 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1607837
18 April 2002 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1607729
4 May 2001 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1469682
16 April 2001 Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1062651
10 May 2000 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1361487
3 March 2000 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1404909
13 October 1999 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1393258
6 May 1999 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1128452
19 April 1999 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1126749
11 March 1999 Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 804453
24 August 1998 Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1132203
11 May 1998 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 791317
9 February 1998 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 774209
18 May 1997 Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1091468
29 April 1997 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1095085
7 June 1996 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 877710
7 June 1996 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1190479
29 April 1996 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1082729
11 April 1996 Deficiency Check · Plan Review "T" Boat
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1080717
18 March 1996 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1077540
22 February 1996 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 885312
29 January 1996 Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1355710
1 May 1995 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1177961
12 May 1994 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 859486
6 April 1994 Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 855848
16 March 1994 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1166843
13 May 1993 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 831671
5 June 1992 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 952043
14 May 1992 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 953603
7 April 1992 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 950609
18 February 1992 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1254184
11 February 1992 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1267151
22 November 1991 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 941148
15 May 1991 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1228828
11 June 1990 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1231274
16 May 1990 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1212335
2 June 1989 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1040743
13 July 1988 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 897684
20 June 1988 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 896024
31 March 1988 Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 992048
11 March 1988 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1033311
22 July 1987 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1021809
12 June 1987 COI Inspection · Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1337918

Deficiency record · 62

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 13 July 2023 No resolution recorded
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel is overdue for an Annual Inspection. Complete Annual Inspection prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 July 2023 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 13 July 2023 No resolution recorded
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel is overdue for drydock examination and internal structural examination. Complete credit Hull Exam prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 July 2023 — due date passed with no resolution recorded
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 18 December 2020 Resolved
Penetrations of required watertight bulkheads by any rigid plastic pipe systems are prohibited, except when: Each such penetration is accomplished using a metallic fitting, welded or otherwise attached to the bulkhead by an accepted method; and an acceptable metallic shutoff valve is installed adjacent to the through bulkhead fitting. This valve shall be operable from above the bulkhead deck. There is a plastic sewage pipe penetrating the watertight bulkhead between the engine room and the tank space without valves. 46 CFR 182.40-1
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 January 2021
Resolved 29 January 2021
Resolution: Bulkhead penetration was capped with a 2.5" steel threaded steel plug. PVC sewage pipe disconnected, system no longer in service as per Master [name withheld]
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 1 December 2020 Resolved
The vessel fire pump must be capable of pumping at a pressure not less than 60 psi. The gauge on the pump was reading ~32 psi. Ensure the pump is capable of meeting the minimum pumping pressure.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 December 2020
Resolution: Observed the correct operation of the firepump.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 1 December 2020 Resolved
At each inspection for certification the marine inspector shall require that all observed unsafe practices and hazardous situations be corrected. The exhaust lagging on the main service generator is saturated with oil and is creating a fire hazard. Identify the source of the leak, make permanent repairs and install new lagging. 46 CFR 176.25-50
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 December 2020
Resolution: Observed the replacement of the lagging.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 1 December 2020 Resolved
At each inspection for certification the marine inspector shall require that all observed unsafe practices and hazardous situations be corrected. The main service generator is leaking oil and creating a fire hazard. Identify the source of the leak and make permanent repairs. 46 CFR 176.28-50
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 December 2020
Resolution: Observed the source of the leak was secured.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 1 December 2020 Resolved
At each inspection for certification the marine inspector shall require that all observed unsafe practices and hazardous situations be corrected. One of the lube oil lines which connect to the main service generator is leaking oil and creating a fire hazard. Identify the source of the leak and make permanent repairs. 46 CFR 176.28-50
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 December 2020
Resolution: Observed the source of the leak was secured.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 1 December 2020 Resolved
The vessel shall have visual and audible alarms at the operating station to indicate a high water level in each normally unmanned space. The vessel has no bilge high level alarms installed. Install the required bilge alarms in each unmanned space.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 December 2020
Resolution: A new high water alarm system was installed and operable
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 1 December 2020 Resolved
Flexible hose designed for use with hose clamps may be installed with two clamps, at both ends of the hose. There are two lube oil hoses connecting to the main service generator which are not double clamped on both ends. Add clamps to both ends of each line.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 December 2020
Resolved 18 December 2020
Resolution: Both ends are now double clamped.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 1 December 2020 Resolved
Battery connections must be made with permanent type connectors. There are four batteries in the engine room which are utilizing temporary connectors. Replace the temporary connectors with permanent connectors. 46 CFR 183.05-20(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 December 2020
Resolved 18 December 2020
Resolution: The temp connections have been replaced with perm. connections.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 1 December 2020 Resolved
The compass must be illuminated. The compass lacks a light. Ensure the compass has illumination.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 December 2020
Resolution: Verified the correct operation of the light.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 1 December 2020 Resolved
The vessel shall have appropriate charts for the intended voyage that are up to date. The vessel’s charts are not up to date or corrected. Ensure up to date charts are on board.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 December 2020
Resolved 29 December 2020
Resolution: Updated chart onboard.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 1 December 2020 Resolved
Each lighting fixture globe, must have a guard or be made of high strength material. The port light fixture in the engine room is cracked. Replace the light fixture.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 December 2020
Resolved 18 December 2020
Resolution: Confirmed that the light fixture was replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 1 December 2020 Resolved
Penetrations of required watertight bulkheads by any rigid plastic pipe are prohibited. The fuel tank space has a plastic pipe penetrating the watertight bulkhead into the engine room. Report back to the USCG what system this is part of. After reporting the system, submit a plan proposal for addressing the penetration.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 December 2020
Resolved 18 December 2020
Resolution: Upon visiting vessel for a deficiency check, a new deficiency was issued via a second CG835V with a requirement to make the penetration compliant with 46 CFR 182.40-1
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 1 December 2020 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. The port navigation light cover is cracked and not watertight. Make the cover watertight.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 December 2020
Resolved 14 January 2021
Resolution: Lens replaced in kind.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 December 2020 Resolved
Each ring life buoy on a vessel must meet the requirements in 46 CFR 160.050. All three ring buoy's on board have unserviceable grab lines. Replace each ring buoy with a serviceable ring buoy.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 December 2020
Resolved 18 December 2020
Resolution: Ring buoys were replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 July 2019 Resolved
A vessel must be provided with bilge pumps in accordance with Table 182.520(a). Table requires two fixed power pumps. Vessel's bilge pump cannot de-water any spaces.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 August 2019
Resolution: Witnessed satisfactory operation of bilge pump dewatering a void space.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 July 2019 Resolved
Shut-off valves installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel stop fuel flow when servicing accessories. The shutoff valve at the tank shall be operable from outside the tank compartment, preferably from an accessible position on the weather deck. Vessel operator could not close fuel shut off valve.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Resolved 25 July 2019
Resolution: Vessel crew worked shut off valve to ensure proper operability.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 July 2019 Resolved
Th minimum capacity of power fire pump shall be 50 gallons per minute at a pressure of not less than 60 pounds per square inch at the pump outlet. The pump outlet shall be fitted with a pressure gauge. The fire pressure gauge read 40 psi at the pump outlet while testing the fire main
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2019
Resolved 15 August 2019
Resolution: Vessel's fire pump cannot produce 60 psi but does provide an adequate stream of water from the discharge side of fire hose.
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 25 July 2019 Resolved
Each entrance to a space storing carbon dioxide cylinders, a space protected by carbon dioxide systems, or any space into which carbon dioxide might migrate must be conspicuously marked as stated in 46 CFR 185.612 (g) The entrance to the space storing CO2 cylinders is not marked.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 August 2019
Resolution: Visually inspected newly affixed warning sign to entrance of space containing CO2 cylinders.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 11 September 2018 Resolved
Vsl is broadcasting invalid MMSI, Vsl is broadcasting Invalid Call Sign and Vsl is broadcasting no dimension information (AIS Antenna Position ABCD values equals 0)
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 15 August 2019
Resolution: Verified that AIS information was updated and displaying correct information.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 July 2018 Resolved
Repair steering gear piping and prove proper operation while exercising steering system.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 August 2018
Resolution: Steering gear piping replaced with satisfactory operation of steering system.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 24 July 2018 Resolved
Replace buoyant apparatus with life float. 46CFR 180.205
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 August 2018
Resolution: Vessel is requesting COI amendment to change route type to operate on a LBS within one mile of land. IAW 46CFR180.207(d) new route will not require vessel to carry survival craft.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 24 July 2018 Resolved
Repair/replace vessel's compass and prove proper operation away from dock. 46 CFR 184.402
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 August 2018
Resolved 24 August 2018
Resolution: Received copy of compass deviation card dated 22AUG2018
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 24 July 2018 Resolved
Repair hole in deck at Stbd bow.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 August 2018
Resolved 17 August 2018
Resolution: Hole in deck repaired; clad welded.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 July 2018 Resolved
Remove dead-end wires under operating station or terminate in junction box. 46 CFR 183.200(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 August 2018
Resolved 17 August 2018
Resolution: Electronic module associated with dead-end wires removed until proper installation can be performed.
Construction/Loadline › Hull › Hull Plating
Issued 31 March 2016 Resolved
Crop and renew hole on bulkhead between engine room and lazarette on port side.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2016
Resolved 6 May 2016
Resolution: Clad welding permitted to complete repair. Repair SAT.
Construction/Loadline › Hull › Longitudinal Frame
Issued 31 March 2016 Resolved
02 Frames on STBD side of lazarette are wasted. Crop and renew.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2016
Resolved 6 May 2016
Resolution: Review of additional stiffeners added showed increased structure in the space. SAT.
Construction/Loadline › Structures › Scuttle
Issued 26 March 2009 Resolved
Hatch covers exposed to the weather missing retaining device.
Action required: 705 - Other - as specified
Due 26 April 2009
Resolved 13 April 2009
Lifesaving › Line-Throwing Appliances › Lines
Issued 26 March 2009 Resolved
Lines on all liferings wasted. Replace to original condition.
Action required: 705 - Other - as specified
Due 26 April 2009
Resolved 13 April 2009
Fire Fighting › Ventilation Systems › Ducts
Issued 6 March 2008 Resolved
Provide method to secure natural ventilation
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2008
Resolved 26 March 2009
Resolution: O3 vent closures to enginge compartment constructed and found to be satisfactory.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 11 April 2006 Resolved
Replace two child size life jackets
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 April 2006
Resolved 11 April 2006
Resolution: Replaced same.
Communications › Alarms/Indicators › Bilge Alarm
Issued 11 April 2006 Resolved
Replace inoperative high leval alarm in engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 April 2006
Resolved 11 April 2006
Resolution: Replaced same.
Lifesaving › Lifejacket/PFD (General)
Issued 15 April 2003 Resolved
Prior to carrying passengers less than 90 pounds (child) repair retro tape on 6 child life jackets. LEGACY COMPONENT DESC: Retroreflective Material
Action required: 705 - Other - as specified
Due 29 April 2003
Resolved 23 April 2003
Lifesaving › Lifejacket/PFD (Type I)
Issued 15 April 2003 Resolved
Vessel is limited to 51 adult passengers until 1 more adult life jacket is provided.
Action required: 705 - Other - as specified
Due 29 April 2003
Resolved 23 April 2003
Engineering
Issued 15 April 2003 Resolved
Remove portable gas tank from vessel.
Action required: 705 - Other - as specified
Due 29 April 2003
Resolved 23 April 2003
Lifesaving › Buoyant Apparatus
Issued 22 April 2002 Resolved
Replace the sea painter on the B.A.
Due 1 May 2002
Resolved 10 May 2002
Engineering › Bilge Water Management System
Issued 22 April 2002 Resolved
Repair the reach rod for the collision bulkhead bilge valve.
Condition: Unknown
Due 1 May 2002
Resolved 10 May 2002
Electrical › Electrical Distribution System (service)
Issued 22 April 2002 Resolved
Place drip pans over the aft engine room distribution panels. LEGACY COMPONENT DESC: Switchboard
Condition: Unknown
Due 1 May 2002
Resolved 10 May 2002
Electrical › Electric Generation Source (emergency)
Issued 22 April 2002 Resolved
Replace/Recharge the battery for the emergency generator.
Condition: Unknown
Due 10 May 2002
Resolved 10 May 2002
Lifesaving
Issued 22 April 2002 Resolved
Prove proper replacement of the EPIRB battery. Vsl operation is limited to 3 miles from shore until requirement is met.
Due 1 May 2002
Resolved 10 May 2002
Navigation
Issued 4 May 2001 Resolved
Install permanent pin in starboard steering ram.
Condition: Unknown
Due 18 May 2001
Resolved 18 May 2001
Navigation
Issued 4 May 2001 Resolved
Provide current compass deviation table for magnetic compass.
Condition: Unknown
Due 18 May 2001
Resolved 18 May 2001
Lifesaving
Issued 4 May 2001 Resolved
Provide "no smoking" sign on vessel's cargo deck.
Condition: Unknown
Due 18 May 2001
Resolved 18 May 2001
Construction/Loadline
Issued 3 March 2000 Resolved
RENEWED 4X5 FOOT BOTTOM PLATE IN THE #2 VOID STARBOARD SIDE INWAY OF AFT_x001C_ BULKHEAD STARBOARD SIDE CHINE.
Condition: Unknown
Due 3 March 2000
Resolved 3 March 2000
Construction/Loadline
Issued 19 April 1999 Resolved
PROVIDE HIGH LEVEL BILGE ALARM FOR AFT STEERING COMPARTMENT.
Condition: Unknown
Due 7 May 1999
Resolved 6 May 1999
Fire Fighting
Issued 11 May 1998 Resolved
PROVE ADEQUATE (60 PSI) OUTLET PRESSURE FROM FIRE PUMP AS PER 46 CFR 181.300(b).
Condition: Unknown
Due 28 May 1998
Resolved 28 May 1998
Documentation
Issued 29 April 1997 Resolved
PROVIDE A COPY OF THE 1996 MIS REPORT. THIS CAN BE CLEARED VIA FAX TO [phone withheld].
Condition: Unknown
Due 6 May 1997
Resolved 18 May 1997
Documentation
Issued 29 April 1997 Resolved
POST THE EMPLOYER DRUG AND ALCOHOL POLICY STATEMENT INCLUDING THE LOCAL DRUG AND ALCOHOL TELEPHONE NUMBERS. THIS CAN BE CLEARED VIA FAX TO [phone withheld].
Condition: Unknown
Due 6 May 1997
Resolved 18 May 1997
Construction/Loadline
Issued 29 April 1996 Resolved
DECK DRAIN LINE WASTED AND HOLED STARBOARD SIDE. LINE LOCATED OVER THE FUEL TANK. CROP TO GOOD STEEL AND RENEW LINE AS ORIGINAL.
Condition: Unknown
Due 11 June 1996
Resolved 11 June 1996
Construction/Loadline
Issued 29 April 1996 Resolved
OVERBOARD DISCHARGE VALVES FROZEN. FREE UPAND PROVE PROPER OPERATION OF ALL OVERBOARD DISCHARGE VALVES.
Condition: Unknown
Due 11 June 1996
Resolved 11 June 1996
Lifesaving
Issued 29 April 1996 Resolved
BUOYANT APPARATUS COVERING CHECKED AND CRACKED. LIFELINE BECKETS DETERIORATED AND BROKEN. RENEW OR REPAIR AS ORIGINAL.
Condition: Unknown
Due 29 April 1996
Resolved 29 April 1996
Deck/Cargo
Issued 29 April 1996 Resolved
SUBMIT PLAN FOR NEWLY INSTALLED DAVIT PORT SIDE MAIN DECK, INCLUDING MANUFACTURES SPECS, HUL MODIFICATIONS, PIPING AND MACHINERY.
Condition: Unknown
Due 11 June 1996
Resolved 11 June 1996
Electrical
Issued 22 February 1996 Resolved
Locate and properly repair indicated electrical ground in vessel.
Condition: Unknown
Due 22 February 1996
Resolved 29 February 1996
Construction/Loadline
Issued 22 February 1996 Resolved
RENEW GASKET TO LAZARETTE HATCH ON FAR PORT SIDE, NO LATER THAN 01 MARCH 96
Condition: Unknown
Due 22 February 1996
Resolved 22 February 1996
Accommodation/Occupational Safety
Issued 22 February 1996 Resolved
PROPERLY CONNECT PIPING IN LAZARETTE COMPARTMENT TO THE FRESH WATER FILL LINE.
Condition: Unknown
Due 22 February 1996
Resolved 22 February 1996
Documentation
Issued 22 February 1996 Resolved
PROVIDE COMPLETE PLANS, IN TRIPLICATE, TO THIS OFFICE FOR PROPOSED MODIFICATIONS TO BOW FOR BOW RAMP INSTALLATION.
Condition: Unknown
Due 22 February 1996
Resolved 22 February 1996
Construction/Loadline
Issued 16 March 1994 Resolved
18" X 18" INSERT COMPLETED PORT QUARTER SIDE SHELL IN VICINITY OF ENGINE EXHAUST.
Condition: Unknown
Due 16 March 1994
Resolved 24 March 1994
Navigation
Issued 14 May 1992 Resolved
MAKE PERMANENT REPAIR TO BROKEN FLOOD LIGHT FIXTURE FOR THE MAIN DECK_x001C_ AREA. ABOVE ITEM TO BE COMPLETED PRIOR TO 28 MAY 1992 TO THE SATISFACTION OF AN ATTENDING COAST GUARD INSPECTOR.
Condition: Unknown
Due 8 June 1992
Resolved 8 June 1992
Construction/Loadline
Issued 11 June 1990 Resolved
BOTTOM PLATE WASTED IN ENGINEROOM BILGE CENTERLINE BENEATH SS GENERATOR. 7FT LONG 1.5FT WIDE INSERT MADE TO WASTED PORT AND STDB GARBOARD STRAKES.
Condition: Unknown
Due 11 June 1990
Resolved 11 June 1990
Fire Fighting
Issued 12 June 1987 Resolved
MOUNT BII FIRE EXTINGUISHER FOWARD ACCOMODATION SPACE
Condition: Unknown
Due 12 June 1987
Resolved 12 June 1987
Lifesaving
Issued 12 June 1987 Resolved
PROCURE ELEVEN TYPE I ADULT PFD'S
Condition: Unknown
Due 12 June 1987
Resolved 12 June 1987

Casualty record · 1

11 June 2018Routine · role: Involved in a Marine Casualty · activity 6442252
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.