Records from 2006 to 2016. Most recent: inspection, 10 February 2016.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 9 December 2010
Resolved
Waterlight was inoperable; battery needs to be replaced.
Due 31 December 2010
Resolved 6 January 2011
Resolution: Waterlight was completely replaced and new battery was installed.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 9 December 2010
Resolved
Stbd nav light was inoperable.
Due 31 December 2010
Resolved 6 January 2011
Resolution: Stbd nav light bulb was replaced and proved to be operable.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 9 December 2010
Resolved
Tides/Currents tables were not onboard.
Due 31 December 2010
Resolved 6 January 2011
Resolution: Tides & currents tables were located onboard the vessel.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 9 December 2010
Resolved
Anchor was not of appropriate size for the vessel. Anchor onboard was rated for vessels of up to 24ft in length.
Due 31 December 2010
Resolved 6 January 2011
Resolution: Anchor was replaced with one fit for the vessel''s size.
Fire Fighting › Means of Escape › Emergency Lighting
Issued 9 December 2010
Resolved
Emergency lighting on canopy was inoperable.
Due 31 December 2010
Resolved 6 January 2011
Resolution: Emergency lighting was tested and proved to be operable.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 9 December 2010
Resolved
Emergency drills and training logs were not onboard.
Due 31 December 2010
Resolved 6 January 2011
Resolution: Emergency drills and training logbooks were verified on the vessel.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 9 December 2010
Resolved
Expired items in first aid kit need to be replaced.
Due 31 December 2010
Resolved 6 January 2011
Resolution: Expired first aid kit items were replaced with ones that were not expired.
Lifesaving › Lifebuoys › Serviceable
Issued 1 December 2009
Resolved
Properly renew worn out retroflective tape on vsl's life ring bouy and restencil vessels' name onto the same.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 January 2010
Resolved 25 January 2010
Personnel › Training › First Aid/CPR
Issued 1 December 2009
Resolved
Provide proof of First Aid training for 50% of your vsl's crew.
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 January 2010
Resolved 25 January 2010
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 1 December 2009
Resolved
Have onboard operating area tide/tidal current tables.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 January 2010
Resolved 25 January 2010
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 1 December 2009
Resolved
Provide the OCMI a copy of employees enrolled in your drug consortium program.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 January 2010
Resolved 25 January 2010
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 11 March 2009
Resolved
Renew/repair deteriorated grab line on the lifebuoy.
Due 25 March 2009
Resolved 1 April 2009
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 11 March 2009
Resolved
Replace one adult type-one PFD due to deterioration. Vessel is pax coumt reduced by one until new PFD is purchased.
Due 25 March 2009
Resolved 1 April 2009
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 11 March 2009
Resolved
Provide log book/records to include voyages, lifesaving and firefighting maintenance and required man overboard and fire drills.
Due 25 March 2009
Resolved 1 April 2009
Navigation › Piloting/Steering › Coast Guard Light List
Issued 11 March 2009
Resolved
Provide current light list.
Due 25 March 2009
Resolved 1 April 2009
Navigation › Piloting/Steering › US Coast Pilot
Issued 11 March 2009
Resolved
Provide current US Coast Pilot.
Due 25 March 2009
Resolved 1 April 2009
Navigation › Piloting/Steering › Marine Charts
Issued 11 March 2009
Resolved
Provide current/updated chart.
Due 25 March 2009
Resolved 1 April 2009
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 11 March 2009
Resolved
Provide complete first aid kit.
Due 25 March 2009
Resolved 1 April 2009
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 23 January 2008
Resolved
Missing pin and tag portable fire ext.
Condition: Improper/Lack of Maintenance
Due 8 February 2008
Resolved 14 February 2008
Resolution: Replaced pins on fire ext.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 23 January 2008
Resolved
Location of lifejacket storage
Condition: Improper/Lack of Maintenance
Due 8 February 2008
Resolved 14 February 2008
Resolution: Marked lifejack stowage locations
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 23 January 2008
Resolved
Missing anti syphon valve
Due 8 February 2008
Resolved 14 February 2008
Resolution: Install anti syphon valve
Lifesaving › Hand Flares › Quantity
Issued 23 January 2008
Resolved
Missing two night flares.
Condition: Improper/Lack of Maintenance
Due 8 February 2008
Resolved 14 February 2008
Resolution: Added two flares
Documentation › Markings/Placards › Lifejacket Placard
Issued 19 October 2006
Resolved
Properly label child L/J stowage.
Condition: Improper Installation
Due 2 November 2006
Resolved 20 October 2006
Resolution: Labeled.
Navigation › Piloting/Steering › Gyro Compass
Issued 19 October 2006
Resolved
Properly install missing Gyro compass.
Condition: Improper Installation
Due 2 November 2006
Resolved 20 October 2006
Resolution: Installed properly.
Documentation › Markings/Placards › Warning Signs
Issued 19 October 2006
Resolved
Properly label fuel tank emergency shut offs.
Condition: Placed in Improper Service
Due 2 November 2006
Resolved 20 October 2006
Resolution: Labeled.