Records from 2016 to 2026. Most recent: inspection, 15 April 2026.
Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
Documentation record
Registered dimensions (L × B × D)153.3 ft × 36.0 ft × 12.0 ft
Registered tonnagegross 193 / net 131
ITC dimensions (L × B × D)153.3 ft × 36.0 ft × 12.0 ft
ITC tonnagegross 567 / net 170
BuilderMARINER LLC · HOUMA, LA, UNITED STATES · built 2009
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 31 March 2026 · expires 30 April 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it193 - Regulatory (Subpart C or D), Gross Ton
567 - Convention (Subpart B), Gross Ton
131 - Regulatory (Subpart C or D), Net Ton
1198 - Displacement, Ton
659 - Dead Weight, Ton
170 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 21
15 April 2026
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8327714
21 January 2026
Type not recorded
No type recorded · USCGC YELLOWFIN (WPB 87319) · USCG Southeast District (CGD-SE) · Activity 8301034
24 September 2025
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8240365
1 April 2025
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8103478
4 October 2024
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8015752
26 August 2024
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7989464
19 January 2024
Administrative Inspection · MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7847107
21 December 2023
Cargo Tank Internal · Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7841570
17 April 2023
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7669926
24 November 2021
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7356978
17 November 2021
Cargo Tank Internal · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7352668
21 April 2021
Periodic Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7179626
11 May 2020
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6951268
10 April 2020
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6937862
7 February 2019
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6621966
29 January 2019
Hull Examination · Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6616947
15 May 2018
Type not recorded
No type recorded · Station Lake Charles · USCG Heartland District (CGD-H) · Activity 6414646
8 February 2018
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6352451
12 January 2017
Deficiency Check · Administrative Inspection · Periodic Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6071985
9 January 2017
Administrative Inspection · Internal Structural Exam · Drydock Exam · Cargo Tank Internal
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6068068
25 February 2016
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5822106
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 15 April 2026
Resolved
On all US documented vessel at least 75 percent of all
crew excluding officers must be US citizens. Vessel had
only 1 unlicensed crewmember out of 3 that
was a US citizen.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 15 April 2026
Resolution: Vessel provided an alternate crew with US citizen status.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 19 January 2024
Resolved
In each crew berthing area and wash area, the owner or operator must display information in a visible location regarding sexual assault and sexual harassment, retaliation, and drug and alcohol usage and the procedures and resources to report crimes, including sexual assault and sexual harassment IAW 46 USC 11101 and CVC Policy Letter 23-04. Vessel had not yet equipped each berthing areas and wash area.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 February 2024
Resolved 1 February 2024
Resolution: Vessel Rep provided update to SASH policy sign after ODYSSEA SPIRIT inspection.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 19 January 2024
Resolved
Vessels shall maintain a master key control system,
control access and use of master keys, and observe specific information handling protocols as
required IAW 46 USC 3301 and CVC Policy Letter 23-06. Vessel did not have a master key control system or policy in place as the master key was given to the licensed bridge officer on watch.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 February 2024
Resolved 20 February 2024
Resolution: Master [name withheld] added to SMS.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 19 January 2024
Resolved
Fire and abandon ship drills must be held on each vessel, normally on alternate weeks; nor shall be held as part of, nor immediately before or after the other. Vessel was conducting fire and abandon ship drills immediately before or after the other. 10C - MIs educated master, crew and company personnel. Recommended revising drill requirement sheet to reflect above requirement.
Action required: 10 - Deficiency Rectified
Resolved 19 January 2024
Resolution: Educated master, crew and vessel rep on requirements of alternate weeks.
14 - Pollution Prevention › N/A - No Subsystem › VGP: General
Issued 17 April 2023
Resolved
Nontank vessels carrying oil as fuel for propulsion operating on the navigable waters of the U.S. that are 400 Gross tons or more under the convention measurement system are to maintain a Non-Tank Vessel Response Plan; vessel did not have required plan.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2024
Resolved 9 May 2023
Resolution: NTVRP developed and CG approved as of 04MAY23.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 24 November 2021
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 December 2021
Resolved 24 November 2021
Resolution: New certificate onboard.
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 24 November 2021
Resolved
Loadline must be permanently marked to the satisfaction of the assigning authority. Loadline on side of vessel did not match loadline certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 December 2021
Resolved 10 December 2021
Resolution: ABS surveyor measured to ensure that the AB line matched the “Summer” line at exactly 1’8” and 1/8. Loadline marking was reapplied to match the loadline cert.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 24 November 2021
Resolved
Stand by vessels must have at least two searchlights. Two out of three searchlights were inoperable.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 December 2021
Resolved 10 December 2021
Resolution: Installed new lightbulbs for the searchlights.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 November 2021
Resolved
Instruction placards for lifejackets. Placards onboard do not match type/style of lifejackets onboard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 December 2021
Resolved 8 December 2021
Resolution: New life jacket placards were installed on board.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 21 April 2021
Resolved
The center of the loadline ring shall be placed amidships and at a distance equal to the assigned summer freeboard. The center of the ring was lined up with the winter freeboard. Additionally, the loadline marks were not painted on their correct marks.
46 CFR 42.13-25
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2021
Resolved 22 April 2021
Resolution: Repainted loadlines.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 21 April 2021
Resolved
Each muster station and embarkation station must be adequately illuminated by lighting supplied from the emergency source of power. Stbd liferafts muster/embarkation station was not lit under emergency power.
46 CFR 133.110(d)
Action required: 17 - Rectify deficiencies prior to departure
Due 21 April 2021
Resolved 22 April 2021
Resolution: Replaced light bulb.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 11 May 2020
Resolved
Vessel rudder angle indicator on aft steering station was misaligned. Vessel rep to adjust indicator.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 11 May 2020
Resolved 11 May 2020
Resolution: Corrected prior to completion of inspection.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 11 May 2020
Resolved
Identified emergency lights in the engine room that were inoperable. Vessel rep replaced lights prior to inspection completion.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 11 May 2020
Resolved 11 May 2020
Resolution: VSL replaced lights prior to completion of the inspection
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 May 2020
Resolved
Vessel was using the incorrect lifejacket donning placard for the lifejackets equipped on the vessel. Vessel Rep to replaces placards with the correct instructions.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 11 May 2020
Resolved 11 May 2020
Resolution: VSL printed correct lifejacket donning placards before completion of inspection.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 7 February 2019
Resolved
Return F/O line on Port Main Diesel Engine leaking against bulkhead behind switchboard. Vital system piping needs repair.
Action required: 60 - Rectify deficiencies prior to movement
Due 7 February 2019
Resolved 7 February 2019
Resolution: New return fuel line collar installed.
Engineering › Pressure Vessel › Marking and Stamping
Issued 8 February 2018
Resolved
Clean/ remove paint from port PV data plate.
Action required: 705 - Other - as specified
Due 22 February 2018
Resolved 22 February 2018
Resolution: Received picture of cleaned off PV data plate.
Operations/Management › Pollution › Compliance with Transfer Procedures
Issued 8 February 2018
Resolved
Provide line diagram for transfer procedures at fuel transfer controls.
Action required: 705 - Other - as specified
Due 22 February 2018
Resolved 22 February 2018
Resolution: Received copy of fuel transfer diagram and statement from Ops manager that it had been posted at transfer station.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 8 February 2018
Resolved
Properly secure MOB rescue platform to vessel to prevent shifting in sea state when deployed.
Action required: 705 - Other - as specified
Due 22 February 2018
Resolved 22 February 2018
Resolution: Received picture of MOB platform secured to vessel via chain.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 8 February 2018
Resolved
Shorten line attached to MOB harness to prevent crew member from floating too far aft during MOB recovery.
Action required: 705 - Other - as specified
Due 22 February 2018
Resolved 8 February 2018
Resolution: Witnessed crew cut and splice line to appropiate length.
Electrical › Electrical Distribution System (service) › Switch
Issued 8 February 2018
Resolved
Properly label location for range disconnect breaker.
Action required: 705 - Other - as specified
Due 22 February 2018
Resolved 8 February 2018
Resolution: Signage was created and posted before the end of the inspection.
Electrical › Electrical Distribution System (emergency) › Distribution Panel Bus
Issued 12 January 2017
Resolved
Provide properly labled fire alarm panel on bridge.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 January 2017
Resolved 15 January 2017
Resolution: Properly labled fire alarm panel.
Electrical › Electric Generation Source (service) › Ground Indicator
Issued 12 January 2017
Resolved
Ground indicator for #2 gen was not working properly.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 January 2017
Resolved 12 January 2017
Resolution: 3rd party located the issue and corrected the item.
Engineering › Compressed Air System (start air) › Valve
Issued 12 January 2017
Resolved
P/S air recievers had improper pop off valves.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 January 2017
Resolved 12 January 2017
Resolution: Corrected on the spot. Replaced with new valves.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 25 February 2016
Resolved
Vessel was not conducting Maintenance IAW it's SMS during warm stack. Required vessel rep to comply with Vessel SMS
Due 25 March 2016
Resolved 25 March 2016
Resolution: Met with Odyssea, they amended their SMS to cover all CG and manufacturer requirements while warm stacked.