← All vessels
PLUM ISLAND
Passenger (Inspected) · Passenger Ship class · Built 2000s · USCG Northeast District (CGD-NE) · Other hulls named PLUM ISLAND
PLUM ISLAND is a 2007 passenger vessel (inspected). The Coast Guard has recorded 44 inspections since 2007, most recently in May 2026, along with 49 deficiencies, 1 operational control and 5 casualty investigations between 2007 and 2021.
Records from 2007 to 2026. Most recent: inspection, 21 May 2026.
- Built
- 2007
- Last inspected
- 21 May 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 49 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 5 investigations · 2007–2021
Identity
1196249
WDD7840
858429
Flag
UNITED STATES
367192060
Maury page id
psix-858429
Inspections, by type
…with no type recorded5
Years with a record
17 calendar years (2007–2026)
The 44 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)112.8 ft × 30.0 ft × 10.0 ft
Registered tonnagegross 93 / net 63
ITC dimensions (L × B × D)112.8 ft × 30.0 ft × 10.0 ft
ITC tonnagegross 257 / net 77
BuilderBLOUNT BOATS INC · WARREN, RI, UNITED STATES · built 2007
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portORIENT, NY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 5 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it93 - Regulatory (Subpart C or D), Gross Ton
257 - Convention (Subpart B), Gross Ton
63 - Regulatory (Subpart C or D), Net Ton
77 - Convention (Subpart B), Net Ton
257 - Convention (Subpart B), Gross Ton
63 - Regulatory (Subpart C or D), Net Ton
77 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDD7840MMSI 367192060 · active · compulsorily equipped · granted 14 April 2017, expires 5 June 2027
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 44
21 May 2026
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8378031
19 August 2025
Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8212832
9 September 2024
Examination of Repairs · Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7999237
5 June 2024
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7926321
7 August 2023
Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7754814
3 May 2023
Deficiency Check · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7662778
22 March 2022
Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7412264
30 November 2021
Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7363225
8 October 2021
Deficiency Check · Administrative Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7330740
23 September 2021
Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7311043
7 July 2021
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7248240
13 July 2020
Damage Survey
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7007639
2 July 2020
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6984713
26 September 2019
Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6799158
28 March 2019
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6650694
12 July 2018
Administrative Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6476516
29 March 2018
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6377351
22 March 2018
Examination of Repairs
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6376886
30 January 2018
Examination of Repairs
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6346484
16 November 2017
Damage Survey
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6308601
29 August 2017
Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6254731
27 July 2017
Internal Structural Exam · Drydock Extension
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6222310
15 February 2017
Deficiency Check · COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6088882
25 May 2016
Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5886529
19 April 2016
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5857785
3 February 2016
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5824695
2 September 2015
Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5233762
20 July 2015
Annual Inspection · Drydock Extension
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5190517
12 June 2014
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4890921
23 May 2014
Damage Survey
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 4866464
23 May 2014
Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 4873239
25 June 2012
Internal Structural Exam · COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4355760
23 April 2009
Drydock Extension
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3459020
21 October 2008
Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3348742
3 September 2008
Examination of Repairs · In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3316715
18 June 2008
Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3247095
7 May 2008
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3201019
15 January 2008
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3131964
20 November 2007
Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3102220
10 September 2007
Plan Review "T" Boat · Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3059940
16 July 2007
Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2996741
2 July 2007
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2984446
27 June 2007
COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2973938
26 February 2007
Inclining Experiment · Initial Certification · Deficiency Check · Construction Oversight
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2877707
Deficiency record · 49
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 9 September 2024
Resolved
C/R stbd side shell in way of the intake plenum to good metal.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 9 September 2024
Resolved
C/R port side shell in way of intake plenum to good metal.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 9 September 2024
Resolved
C/R fwd and aft bulkhead in way of port side plenum where wasted through to good metal.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 9 September 2024
Resolved
Descale areas in port and stbd intake plenums as necessary to identify the condition of steel to the satisfaction of the attending USCG MI.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 May 2023
Resolved
Regarding fire pump: Pump outlet must be fitted with a pressure gauge (60psi). Gauge is not working, replace. 46 CFR 181.300(b)
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 3 May 2023
Resolved
The COI must be posted such that all pages are visible in a conspicuous place where observation by passengers is likely. COI is not posted where visible to passengers. Post COI. 46 CFR 176.302
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 22 March 2022
Resolved
Complete but simple instructions for operation of a fixed gas fire extinguishing system must be located in a conspicuous place; at or near each pull box. Labeling for CO2 system has faded instructions on the deck bulkhead. Update label to be legible.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 March 2022
Resolved
Provide updated enrollment in a DAPI program with a list of current enrolled crew.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 22 March 2022
Resolved
Vessel must show proper operation of bilge suction, pump and bilge piping.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 7 July 2021
Resolved
Vessel was two days past due for the annual inspection. The COI was issued on 05Apr17. Vessel had to 05Jul21 to complete the inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 July 2021
Resolved
Reach rod for the fore peak bilge closure valve was not operational.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 July 2020
Resolved
Port generator produced sparks from the cooling air duct at start up.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 28 March 2019
Resolved
Provide DSC Capable radio at operating station & program in vessels MMSI #. Deficiency issued for failing to upgrade the VHF Radio by 20Jan2016. Per CVC Policy Letter 15-06.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 29 March 2018
Resolved
CO2 high pressure cylinders overdue for hydrostatic testing.
Engineering › Steering Gear System › Rudder Bearing
Issued 29 March 2018
Resolved
According to vessel operator, the port rudder seal is still weeping while the vessel is loaded. This is after attempted repair at drydock. Operator to provide plan for modification to rudder seal.
Engineering › Steering Gear System › Rudder
Issued 22 March 2018
Resolved
Conduct underway rudder exam.
Engineering › Steering Gear System › Rudder Bearing
Issued 30 January 2018
Resolved
Repair leaking port rudder bearing.
Engineering › Steering Gear System › Rudder Bearing
Issued 16 November 2017
Resolved
Port rudder was leaking water excessively
Engineering › Steering Gear System › Rudder Stock
Issued 15 February 2017
Resolved
Re-install bolt on port side rudder flange bearing.
Operations/Management › Drills/Instruction › Launching/Recovery of Survival Craft
Issued 15 February 2017
Resolved
Renew life-raft operating instruction placards.
Communications › Alarms/Indicators › High Water Alarm
Issued 19 April 2016
Resolved
Both port and starboard engine alarm panels located at the operating station were not working properly and did not have a functional audible alarm.
Engineering › Steering Gear System › Hydraulic Hose
Issued 21 July 2015
Resolved
Repair hydraulic leaks on piping at steering pump.
Engineering › Steering Gear System › Hydraulic Hose
Issued 21 July 2015
Resolved
Repair hydraulic leaks on bow thruster piping above the tunnel.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 12 June 2014
Resolved
Provide FCC Safety Certificate
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 12 June 2014
Resolved
Properly label lifejacket storage on upper deck.
Documentation › Markings/Placards › Lifejacket Placard
Issued 12 June 2014
Resolved
Provide lifejacket donning placard on upper deck.
Engineering › Sea-water System (primary cooling) › Piping
Issued 23 May 2014
Resolved
Bow thruster hydraulic oil cooler was discharging oil into seawater cooling water overboard discharge. Properly repair or replace bow thruster hydraulic oil cooler. Prove proper operation to satisfaction of CG Marine Inspector.
Engineering › Fuel Oil Service System › Valve, Control
Issued 25 June 2012
Resolved
Service starboard remote fuel shutoff so that it operates and resets properly. Due by the next drydock.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 7 May 2008
Resolved
Increase the size of the port side forward life jacket locker opening in aft conference pit.
Electrical › Electric Supply System (service) › Cable
Issued 7 May 2008
Resolved
Secure cable under port aft conference pit bench
Communications › Alarms/Indicators › Bilge Alarm
Issued 7 May 2008
Resolved
Provide better access to bilge high level alarm in galley space.
Communications › Alarms/Indicators › General Alarm
Issued 7 May 2008
Resolved
Prove proper operation of WTD alarm on the bridge for door form the E/R to the machinery space.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 7 May 2008
Resolved
Provide effective means to recover man over board. Provide means to get a victim to the deck to the rescue platform.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 7 May 2008
Resolved
Secure rescue platform in close proximity to loading doors
Engineering › Thrusters › Tunnel
Issued 7 May 2008
Resolved
Ensure bow thruster tunnel is installed IAW manufactures instructions. (excessive vibration)
Communications › Alarms/Indicators › Fire Alarm
Issued 7 May 2008
Resolved
Make repairs to fire alarm in the engine room
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 7 May 2008
Resolved
Repair gaskets on CO2 pull stations.
Engineering › Fuel Oil Service System › Piping
Issued 7 May 2008
Resolved
Provide effective means to isolate fuel from machinery space.
Electrical › Electric Supply System (service) › Cable
Issued 7 May 2008
Resolved
Remove wire nuts and secure wires IAW regulations on both main engines (at starters) and engine room fans.
Electrical › Electrical Distribution System (emergency) › Ground Detection
Issued 7 May 2008
Resolved
Make repairs to the battery charger circuit, clear ground.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 27 June 2007
Resolved
Stencil CO2 alarm in furnace space.
Construction/Loadline › Structures › Deck Plating
Issued 27 June 2007
Resolved
Provide addtional support for deck plates in front of swtichboard in the engine room.
Construction/Loadline › Structures › Scuttle
Issued 27 June 2007
Resolved
Provide proper scuttle for egress hatch in the furnace space and label it on the main deck.
Navigation › Piloting/Steering › Marine Charts
Issued 26 February 2007
Resolved
Prior to carrying passengers provide the appropriate charts, logs, manuals and publications for the operating area to the satisfaction of the attending marine inspector.
Personnel › Training › Familiarization Training
Issued 26 February 2007
Resolved
Prior to carrying passengers conduct a new to zone inspection to the satisfaction of the attending marine inspector.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 26 February 2007
Resolved
Prior to carrying passengers provide documentation that the crew is enrolled in an approved drug and alcohol program to the satisfaction of the attending marine inspector.
Operations/Management › Drills/Instruction › Not Conducted
Issued 26 February 2007
Resolved
Prior to carrying passengers conduct underway fire and person overboard drills to the satisfaction of the attending marine inspector.
Documentation › Certificates/Documents › FCC SSL
Issued 26 February 2007
Resolved
Prior to carrying passenger provide the FCC Station License and FCC Safety Certificate to the satisfaction of the attending marine inspector.
Engineering › Thrusters › Motor
Issued 26 February 2007
Resolved
Prove proper operation of the bow thruster to the satisfaction of the attending marine inspector.
Casualty record · 5
2 July 2007Routine · role: Involved in a Marine Casualty · activity 2984446
15 January 2008Routine · role: Involved in a Marine Casualty · activity 3131964
1 July 2013Routine · role: Involved in a Marine Casualty · activity 4697904
3 February 2016Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 5824695
30 November 2021Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 7363225
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.