Records from 2007 to 2026. Most recent: inspection, 21 May 2026.
Documentation record
Registered dimensions (L × B × D)112.8 ft × 30.0 ft × 10.0 ft
Registered tonnagegross 93 / net 63
ITC dimensions (L × B × D)112.8 ft × 30.0 ft × 10.0 ft
ITC tonnagegross 257 / net 77
BuilderBLOUNT BOATS INC · WARREN, RI, UNITED STATES · built 2007
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portORIENT, NY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 5 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it93 - Regulatory (Subpart C or D), Gross Ton
257 - Convention (Subpart B), Gross Ton
63 - Regulatory (Subpart C or D), Net Ton
77 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 26
21 May 2026
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8378031
19 August 2025
Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8212832
9 September 2024
Examination of Repairs · Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7999237
5 June 2024
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7926321
7 August 2023
Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7754814
3 May 2023
Deficiency Check · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7662778
22 March 2022
Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7412264
30 November 2021
Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7363225
8 October 2021
Deficiency Check · Administrative Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7330740
23 September 2021
Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7311043
7 July 2021
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7248240
13 July 2020
Damage Survey
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7007639
2 July 2020
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6984713
26 September 2019
Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6799158
28 March 2019
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6650694
12 July 2018
Administrative Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6476516
29 March 2018
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6377351
22 March 2018
Examination of Repairs
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6376886
30 January 2018
Examination of Repairs
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6346484
16 November 2017
Damage Survey
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6308601
29 August 2017
Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6254731
27 July 2017
Internal Structural Exam · Drydock Extension
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6222310
15 February 2017
Deficiency Check · COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6088882
25 May 2016
Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5886529
19 April 2016
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5857785
3 February 2016
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5824695
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 9 September 2024
Resolved
C/R stbd side shell in way of the intake plenum to good metal.
Action required: 60 - Rectify deficiencies prior to movement
Due 9 September 2024
Resolved 19 September 2024
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 9 September 2024
Resolved
C/R port side shell in way of intake plenum to good metal.
Action required: 60 - Rectify deficiencies prior to movement
Due 9 September 2024
Resolved 19 September 2024
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 9 September 2024
Resolved
C/R fwd and aft bulkhead in way of port side plenum where wasted through to good metal.
Action required: 60 - Rectify deficiencies prior to movement
Due 9 September 2024
Resolved 16 September 2024
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 9 September 2024
Resolved
Descale areas in port and stbd intake plenums as necessary to identify the condition of steel to the satisfaction of the attending USCG MI.
Action required: 60 - Rectify deficiencies prior to movement
Due 9 September 2024
Resolved 12 September 2024
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 May 2023
Resolved
Regarding fire pump: Pump outlet must be fitted with a pressure gauge (60psi). Gauge is not working, replace. 46 CFR 181.300(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2023
Resolved 8 May 2023
Resolution: completed
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 3 May 2023
Resolved
The COI must be posted such that all pages are visible in a conspicuous place where observation by passengers is likely. COI is not posted where visible to passengers. Post COI. 46 CFR 176.302
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2023
Resolved 8 May 2023
Resolution: completed
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 22 March 2022
Resolved
Complete but simple instructions for operation of a fixed gas fire extinguishing system must be located in a conspicuous place; at or near each pull box. Labeling for CO2 system has faded instructions on the deck bulkhead. Update label to be legible.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 April 2022
Resolved 9 April 2022
Resolution: provided
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 March 2022
Resolved
Provide updated enrollment in a DAPI program with a list of current enrolled crew.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 April 2022
Resolved 9 April 2022
Resolution: provided
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 22 March 2022
Resolved
Vessel must show proper operation of bilge suction, pump and bilge piping.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 22 March 2022
Resolved 23 March 2022
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 7 July 2021
Resolved
Vessel was two days past due for the annual inspection. The COI was issued on 05Apr17. Vessel had to 05Jul21 to complete the inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 July 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 July 2021
Resolved
Reach rod for the fore peak bilge closure valve was not operational.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 July 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 July 2020
Resolved
Port generator produced sparks from the cooling air duct at start up.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 July 2020
Resolved 20 July 2020
Resolution: Generator repaired.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 28 March 2019
Resolved
Provide DSC Capable radio at operating station & program in vessels MMSI #. Deficiency issued for failing to upgrade the VHF Radio by 20Jan2016. Per CVC Policy Letter 15-06.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 April 2019
Resolved 15 April 2019
Resolution: Vessel has on board VHF with DSC
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 29 March 2018
Resolved
CO2 high pressure cylinders overdue for hydrostatic testing.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 April 2018
Resolution: Received tech report for hydrostatic testing.
Engineering › Steering Gear System › Rudder Bearing
Issued 29 March 2018
Resolved
According to vessel operator, the port rudder seal is still weeping while the vessel is loaded. This is after attempted repair at drydock. Operator to provide plan for modification to rudder seal.
Action required: 705 - Other - as specified
Resolved 20 July 2018
Resolution: New lower bearing and upper seal/bearing installed.
Engineering › Steering Gear System › Rudder
Issued 22 March 2018
Resolved
Conduct underway rudder exam.
Action required: 705 - Other - as specified
Resolved 29 March 2018
Resolution: Underway examination of rudder conducted. No leaks observed.
Engineering › Steering Gear System › Rudder Bearing
Issued 30 January 2018
Resolved
Repair leaking port rudder bearing.
Due 23 March 2018
Resolved 5 April 2018
Resolution: Administratively closed. Multiple 835s entered for same deficiency.
Engineering › Steering Gear System › Rudder Bearing
Issued 16 November 2017
Resolved
Port rudder was leaking water excessively
Due 30 November 2017
Resolved 5 April 2018
Resolution: Administratively closed. Multiple 835s entered for same deficiency.
Engineering › Steering Gear System › Rudder Stock
Issued 15 February 2017
Resolved
Re-install bolt on port side rudder flange bearing.
Condition: Improper/Lack of Maintenance
Due 12 April 2017
Resolved 7 April 2017
Resolution: Bolt replaced.
Operations/Management › Drills/Instruction › Launching/Recovery of Survival Craft
Issued 15 February 2017
Resolved
Renew life-raft operating instruction placards.
Condition: Improper/Lack of Maintenance
Due 5 May 2017
Resolved 18 May 2017
Resolution: Placards renewed.
Communications › Alarms/Indicators › High Water Alarm
Issued 19 April 2016
Resolved
Both port and starboard engine alarm panels located at the operating station were not working properly and did not have a functional audible alarm.
Due 20 May 2016
Resolved 25 May 2016
Resolution: Prove proper operation of both port and starboard MDE alarm panel – They are working properly, there is an approx. 60 second delay before Murphy panels go into audible alarm if no engine RPMS are detected.