Records from 2006 to 2026. Most recent: inspection, 18 May 2026.
Inspection history · 77
18 May 2026
Administrative Inspection
Administrative · Activities Europe · Activity 8375247
18 March 2026
Type not recorded
No type recorded · Activities Europe · Activity 8331767
12 January 2026
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8295225
27 October 2025
Administrative Inspection · Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8259195
2 September 2025
MSP Select Annual Oversight · Annual Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8225188
11 July 2025
Type not recorded
No type recorded · Activities Europe · Activity 8187780
19 June 2025
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8163225
24 May 2025
Type not recorded
No type recorded · Activities Europe · Activity 8150662
29 April 2025
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8156741
17 April 2025
Administrative Inspection
Administrative · Activities Europe · Activity 8113099
18 March 2025
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8095566
17 March 2025
Damage Survey · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8094871
17 March 2025
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 8109348
15 February 2025
Type not recorded
No type recorded · Activities Europe · Activity 8173108
21 January 2025
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 8068874
20 January 2025
Type not recorded
No type recorded · Activities Europe · Activity 8070735
5 January 2025
Administrative Inspection
Administrative · Activities Europe · Activity 8057571
25 September 2024
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 8009450
14 August 2024
Annual Inspection · Administrative Inspection · MSP Annual Oversight
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7980879
14 March 2024
Administrative Inspection
Administrative · Activities Europe · Activity 7878936
13 March 2024
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7943845
5 March 2024
Administrative Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7874388
24 February 2024
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7869697
15 February 2024
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7866291
15 February 2024
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7866548
8 November 2023
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7822293
13 October 2023
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7808116
28 August 2023
Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7778942
18 August 2023
Annual Inspection · MTSA/ISPS Verification · MSP Annual Oversight
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7771479
3 July 2023
Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7730615
23 January 2023
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7625815
12 December 2022
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7607689
1 August 2022
MSP Annual Oversight · Annual Inspection · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7521885
7 July 2022
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7499296
31 March 2022
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7422038
30 March 2022
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7421412
29 March 2022
MSP Select Additional Oversight – Risk Assessment · Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7421946
24 January 2022
Administrative Inspection
Administrative · Activities Europe · Activity 7384458
30 December 2021
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7376191
10 August 2021
Administrative Inspection · Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7282825
27 July 2021
MTSA/ISPS Verification · MSP COI Oversight
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7268733
27 May 2021
Administrative Inspection
Administrative · Activities Europe · Activity 7207944
25 February 2021
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7146436
16 February 2021
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7142367
31 October 2020
Examination of Repairs · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7087625
26 October 2020
Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7084222
22 September 2020
Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 7063167
21 September 2020
Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7062284
28 August 2020
Annual Inspection · MSP Annual Oversight
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7044903
17 August 2020
Administrative Inspection
Administrative · Activities Europe · Activity 7035671
3 August 2020
Administrative Inspection
Administrative · Activities Europe · Activity 7023071
3 August 2020
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7029075
12 July 2020
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7121757
11 July 2020
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7003259
3 March 2020
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6919948
29 February 2020
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6918028
23 January 2020
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6895153
29 July 2019
Annual Inspection · MTSA/ISPS Verification · DAPI Audit · MSP Annual Oversight
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6759260
22 February 2019
Administrative Inspection
Administrative · Activities Europe · Activity 6632449
8 February 2019
In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6622266
12 January 2019
Type not recorded
No type recorded · Activities Europe · Activity 6609893
4 October 2018
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6555100
30 July 2018
Ballast Water Examination · MSP Annual Oversight · DAPI Audit · Annual Inspection · MTSA/ISPS Verification · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6496260
12 July 2018
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6476900
21 June 2018
Administrative Inspection
Administrative · Activities Europe · Activity 6451044
7 June 2018
Administrative Inspection
Administrative · Activities Europe · Activity 6444831
31 July 2017
MTSA/ISPS Verification · DAPI Audit · Annual Inspection · MSP Annual Oversight · MARPOL Annex I Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6226441
21 December 2016
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6060898
18 December 2016
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6061822
14 September 2016
Administrative Inspection
Administrative · Activities Europe · Activity 6000346
1 September 2016
Type not recorded
No type recorded · Activities Europe · Activity 5989320
25 May 2016
COI Inspection · MTSA/ISPS Verification
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5886550
13 May 2016
Type not recorded
No type recorded · Activities Europe · Activity 5875971
10 May 2016
Administrative Inspection
Administrative · Activities Europe · Activity 5873270
31 March 2016
Deficiency Check · Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5844316
8 March 2016
Administrative Inspection
Administrative · Activities Europe · Activity 5828939
16 February 2016
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5819622
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 March 2025
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to ship or persons onboard. Vessel experienced a casualty with a failure of internal seal for stern tube causing a loss of lube oil.
Condition: Design Flaw
Action required: 60 - Rectify deficiencies prior to movement
Due 17 March 2025
Resolved 18 March 2025
Resolution: Vessel contacted technician to effect repairs. MIs refered to class and class conducted remote survey to clear discrep. Refer to final action report 2287604.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 25 September 2024
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use.
Vessel's rescue boat release hook is damaged and rescue boat cannot be readily released.
//74 SOLAS (20) III/20.2// 17a
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 October 2024
Resolved 26 September 2024
Resolution: MI recieved class report and short term CSSEC.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 15 February 2024
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Vessel master reported port lifeboat counter weight brake failed to operate during routine drills, rendering the lifeboat inoperable. Vessel is required to have repairs conducted and provide a technician's report and class documentation attesting to the proper operation of the port lifeboat and brake prior to departure from the Port of Charleston.
Action required: 15 - Rectify deficiencies by next port
Due 2 March 2024
Resolved 2 March 2024
Resolution: Accepted Lloyd's Register report# 2235349 (Uploaded) issued by Surveyor [name withheld] that outstanding Deficiency for Lifeboat Davit repairs have been satisfied.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 18 August 2023
Resolved
Only one type of release mechanism shall be used for similar survival craft carried on board the ship. Different release mechanisms were installed on the forward and float-free liferafts which do not match posted instructions. 74 SOLAS (20 Cons) III/16.4 16a
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 September 2023
Resolved 30 August 2023
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 18 August 2023
Resolved
The requirements for providing notice and reporting of marine casualties and for retaining voyage records are contained in subpart 4.05 of this chapter. Vessel's rescue boat winch motor failed around 30 May, 2023, but no notifications were made to either USCG or Class LR. Company is to conduct an investigation to determine the root cause, devlelop and implement any corrective action into the SMS to prevent future occurances. The effectiveness of the implemented corrective action to be verified at the next scheduled extermal audit.
Action required: 705 - Other - as specified
Due 24 November 2023
Resolved 8 November 2023
Resolution: Company Safety Manager provided a copy of the final investigaton report via email, rcvd 8Nov23
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 10 August 2021
Resolved
Vessel shall be escorted by one tug of at least 3,000 horsepower and one tug of 2,000 horsepower or one tug of at least 5,000 horsepower, or; Vessel shall be escorted by one tug of at least 50 ton bollard pull or two tugs of at least 50 ton aggregate pull while transiting Hampton Roads regulated navigation area as defined 33CFR 165.501(a)2.
Action required: 705 - Other - as specified
Due 11 August 2021
Resolved 11 August 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 27 July 2021
Resolved
Doors provided to ensure watertight integrity of internal openings are to be sliding watertight doors capable of being closed from the bridge. Shaft Alley's watertight door was incapable of being closed from the bridge. Prove proper operation to satisfaction of attending CGMI.74SOLAS(04)II-1/25-9.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 July 2021
Resolution: Witnessed proper operation of watertight door closure from bridge.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 27 July 2021
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provision of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Found excessive oil leaks and gear adrift throughout engine room, including unsecured 55 gallon oil drums. Clean and secure to satisfaction of attending CGMI. 74SOLAS(14)I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 July 2021
Resolution: Engine room was cleaned and secured to satisfaction of attending CGMI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 July 2021
Resolved
Oil used in pressure lubrication systems shall be such to ensure the safety of the ship. Found cracked weld on #1 SSDG lub oil filter. Repair crack to the satisfaction of the attending class surveyor. 74SOLAS(04)II-2/4.2.3.1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 August 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 July 2021
Resolved
The #3 SSDG went through an overhaul and experienced damage. Vessel failed to report damage to the classification society. Report damage and repair to the satisfaction of the attending class surveyor. 74SOLAS(14)I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 August 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 July 2021
Resolved
Vessel has numerous leaks on the main engine, to include the turbo. Repair engine and rectify leaks to the satisfaction of the attending class surveyor. 74SOLAS(14)I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 August 2021
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 27 July 2021
Resolved
Vessel has an unauthorized patch on the fire main system. Repair fire main piping properly to the satisfaction of the attending class surveyor. 74SOLAS(14)I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 August 2021
05 - Radio Communications › N/A - No Subsystem › MF/HF Radio installation
Issued 16 February 2021
Resolved
Ships must be provided with radio installations capable of complying with functional requirements prescribed by 47 CFR 80.1081 throughout its intended voyage.
Vessel reported GMDSS is not operational. Vessel is allowed to depart Sector Houston-Galveston AOR to Norfolk, VA to make repairs to the satisfaction of CG Marine Inspector.
Notify USCG Sector Houston-Galveston if anything changes from the plan. Failure to comply with this 835 will be in violation of US regulations and may result in penalties.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 March 2021
Resolved 25 February 2021
Resolution: Received Tech report#NOR0287934 stating satisfactory repairs to FURUNO MF/HF Radio serial#004563 are complete and system is fully operational.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 September 2020
Resolved
Lifejackets shall be so placed as to be readily accessible and thier position shall be plainly indicated. Port side embarkation area marked for four lifejackets, missing two.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 21 September 2020
Resolution: Cleared on the spot.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 21 September 2020
Resolved
Muster and embarkation stations shall be adequately illuminated by lighting supplied from the emergency source of electrical power. Light is out directly above liferafts.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 21 September 2020
Resolution: Cleared on the spot.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 28 August 2020
Resolved
Each power operated sliding door shall be provided with an individual hand operated mechanism. It shall be possible to open and close the door form both sides. The hand operated mechanism was not operating. 74 SOLAS (04) II-1/25-9.2
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 September 2020
Resolution: Accepted by Lloyd's.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 28 August 2020
Resolved
Fire integrity of bulkheads and decks of cargo ships shall be as described in II-1 Reg. 9. Fire stop in bridge radar enclosures and A-deck cable duct MCTs is missing and not installed iaw manufacturer's recommendations. 74 SOLAS (04) II-2/9.2.3.3.1
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 14 September 2020
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 28 August 2020
Resolved
Muster and embarkation stations shall be adequately illuminated by lighting supplied from the emergency source of electrical power. Lifeboat emergency lighting has fixtures that will not illuminate. 74 SOLAS (14) III/11.4
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 September 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 August 2020
Resolved
All ring life buoys shall be of an international or vivid reddish orange. Starboard ring life buoy iwo fwd six man liferaft is discolored. 74 SOLAS (14) III/7.1.1 & LSA II/1.2.2.6
Action required: 10 - Deficiency Rectified
Due 28 August 2020
Resolved 28 August 2020
Resolution: Administrative error, def was corrected on spot during inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 28 August 2020
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Found one immersion suit with a siezed zipper. 74 SOLAS (14) III/20.2
Action required: 10 - Deficiency Rectified
Due 28 August 2020
Resolved 28 August 2020
Resolution: Administrative error, deficiency was cleared on spot during inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 3 March 2020
Resolved
Vessel suffered a complete loss in way of the breaking system on the port launching system which bent the davit arms during an onboard drill rendering the lifeboat launching apparatus unserviceable.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 3 March 2020
Resolved 3 March 2020
Resolution: Vessel added additional liferafts to compensate for the absent lifeboat.
Engineering › Diesel Engine (auxiliary) › Nozzle, Injection (fuel injection)
Issued 21 December 2016
Resolved
Show proper operation of EDG under load.
Action required: 705 - Other - as specified
Due 29 December 2016
Resolved 27 December 2016
Resolution: Vessel showed proper operation of the EDG to the attending class surveyor.
Engineering › Diesel Engine (propulsion-direct drive) › Injector (fuel injection)
Issued 31 March 2016
Resolved
Vessel's #1 cylinder Injector Control Unit on the main engine was found leaking. Vessel's crew had to shutdown and secure #1 cylinder for transit to facility. Vessel is to repair or replace to the satisfaction of a class surveyor.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 31 March 2016
Resolved 31 March 2016
Resolution: Received class report from Lloyds Register (Class) attesting to reparis to the #1 ICU. Class conducted opertional test; all sat.