BALTIC AMBITION is a 2006 tank ship. The Coast Guard has recorded 3 inspections since 2006, most recently in July 2009, along with 2 deficiencies and 1 operational control.
Records from 2006 to 2009. Most recent: inspection, 27 July 2009.
The 3 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Share this recordDownload vessel cardDownload QRMaury, US Coast Guard vessel record for BALTIC AMBITION, retrieved 18 September 2026. mauryrecords.com/v/psix-858582.html
Documentation record
Tonnage as PSIX records it23240 - Convention (Subpart B), Gross Ton 10110 - Convention (Subpart B), Net Ton 37300 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 3
27 July 2009PII Safety Exam · Ballast Water Examination · COC-CHEM Renew · ISPS II Exam
0950 - Electric Equipment in General - Dead ground phase C was identified in the 220V AC ground detection system. Ground needs to be located, isolated and repaired to the satisfaction of class society. SOLAS 74 as amended (2004 consolidated) Ch. II-1 Regulation 45. 50(a)
Action required: 705 - Other - as specified
Due 27 August 2009
Resolved 6 August 2009
Resolution: external light fixture was found with a leaking gland and water accumulation. The fitting was dismantled, dried, cleaned and reconditioned. The fitting was re-installed and 220V AC was tested in the presence of class survey with no issues noted.
Deck/Cargo › Vapor Control Systems › Fixed Vapor Collection Arms
Issued 27 July 2009Resolved
1199 - Cargo (other) - Vapor collection discharge flange was found with a threaded stud and determined not to be permanently affixed. Vapor collection stud must be permanently affixed to prevent removal of the stud and accidental connection of cargo lines. 46 CFR 39.20-1(e). 50(c)
Action required: 705 - Other - as specified
Due 27 August 2009
Resolved 6 August 2009
Resolution: Class surveyor (DNV) attested to permanent attachment of VCS flange stud.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.