Records from 2016 to 2026. Most recent: inspection, 28 March 2026.
Inspection history · 45
28 March 2026
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8436956
23 February 2026
PSC B · COC-CVE Quarterly
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8312791
5 September 2025
Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8227539
25 August 2025
COC-CVE Annual · PSC A
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8217348
20 March 2025
In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8096709
24 February 2025
PSC B · COC-CVE Quarterly
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8083710
20 February 2025
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8081858
23 January 2025
Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8069204
26 August 2024
PSC A · COC-CVE Annual
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7989497
4 April 2024
Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7889837
25 March 2024
In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7884474
24 March 2024
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7884012
11 March 2024
Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7876924
26 February 2024
PSC B · COC-CVE Quarterly
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7869352
11 September 2023
Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7789227
28 August 2023
PSC A · COC-CVE Annual
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7777933
26 July 2023
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7752931
27 March 2023
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7657628
23 March 2023
PSC B · Ballast Water Examination · COC-CVE Quarterly
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7653482
26 September 2022
PSC A · COC-CVE Annual
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7563385
26 May 2022
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7472752
19 April 2022
Deficiency Check · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7433912
3 April 2022
COC-CVE Quarterly · Ballast Water Examination · PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7422289
13 October 2021
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7331649
4 October 2021
PSC A · Administrative Inspection · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7324863
28 September 2021
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7322367
28 April 2020
In-Service Inspection
Physical examination · USCG Southeast District (dp) · USCG Southeast District (CGD-SE) · Activity 6944878
31 March 2020
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6933845
30 March 2020
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6933175
14 January 2020
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6890642
7 December 2019
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6889284
12 October 2019
In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6833273
29 September 2019
COC-CVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6818519
25 March 2019
Deficiency Check · COC-CVE Quarterly · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6636764
29 September 2018
In-Service Inspection · Ballast Water Examination · ISPS III Exam · COC-CVE Annual
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6544733
31 March 2018
Ballast Water Examination · ISPS III Exam · COC-CVE Quarterly
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6369058
10 February 2018
In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6353145
9 December 2017
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7011170
30 September 2017
Ballast Water Examination · ISPS III Exam · COC-CVE Annual
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6277034
30 August 2017
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6255375
14 May 2017
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6166332
1 April 2017
COC-CVE Quarterly · ISPS III Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6108184
1 October 2016
ISPS III Exam · COC-CVE Annual · Ballast Water Examination
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6011474
2 April 2016
Ballast Water Examination · ISPS II Exam · COC-CVE Quarterly
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5843652
26 March 2016
Type not recorded
No type recorded · Station Galveston · USCG Heartland District (CGD-H) · Activity 5841124
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 August 2025
Resolved
09209 - All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner. A fresh water pipe was found with a leak that was spraying in the duct above the galley onto all electrical equipment with in the space.
74 SOLAS 04 II-1/45.1.3
16ac
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 September 2025
Resolved 5 September 2025
Resolution: Vessel submitted satisfactory class report attesting to the repairs on the fresh water pipe and all residual water on electrical equipment was cleaned.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 25 August 2025
Resolved
14104 - Any ship of 10,000 gross tonnage and above shall be fitted with oil filtering equipment complying with paragraph 7 of this regulation. PSCO observed the return line fitted with the three way valve duct taped and leaking water into the bilge.
MARPOL 2017 Annex I/14.2
10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 25 August 2025
Resolved 25 August 2025
Resolution: Pipe leading to the three way valve was replaced.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 25 August 2025
Resolved
07123 - Fire protection systems and fire-fighting systems and appliances shall be maintained ready for use. PSCO found a water mist nozzle with a blue ampule installed in a galley dishwashing space Deck 10 aft, plan states that a yellow ampule should be installed in that space.
74SOLAS 20 II-2/14.1.1
10c
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 25 August 2025
Resolved 25 August 2025
Resolution: The water mist nozzle in the dishwashing space deck 11 aft, was replaced with the appropriate yelllow ample.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 24 February 2025
Resolved
07105 Fire doors in main vertical zone bulkheads,galley boundaries, and stairway enclosures shall be self-closing and be capable of closing with an angle of inclination of up to 3.5* opposing closure. Fire doors #10.009, 9.061, and 9.068 were found not capable of self closing.
74SOLAS(09)II-2/9.4.1.1.4.1 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 24 February 2025
Resolved 24 February 2025
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 24 February 2025
Resolved
04110 Every crew member with assigned emergency duties shall be familiar with these duties before the voyage begins. The second coxswain of lifeboat #24 was not familiar with launching operations and could not identify the fuel shut off valve. 74SOLAS(20)III/19.2.1 10c
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 24 February 2025
Resolved 24 February 2025
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 25 March 2024
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present
regulations to ensure the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. The vessel’s port side funnel wing was damaged as a
result of a fire and the integrity and suitability of the exhaust piping and associated support structures for DG’s 1,2,4,Boiler 2, and the emergency compressor have been compromised
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 April 2024
Resolved 4 April 2024
Resolution: Repairs completed
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 26 February 2024
Resolved
11131 - Every crew member with assigned emergency duities shall be familiar with these duties before the voyage begins. Lifeboat# 25 crew members could not demonstrate familiarity with fire fighting systems onboard the lifeboat. Additionally, 03 crew members from the crew galley and 01 crew members from the aft main galley could not demonstrate nor explain fire fighting procedures for the galley they were assigned to. 74 SOLAS (20) III/19.2.1, Action: 16c
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2024
Resolved 11 March 2024
Resolution: CG attended and cleared via random sampling of crew for fire response/initial actions questioning.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 28 August 2023
Resolved
11131 - Every crew member with assigned emergency duties shall be familiar with theseduties before the voyage begins. Firs and second in command of life boats #12 and #19 and second in command of lifeboat #21 were not familiar with general vessel operations and/or launching procedures. 74SOLAS (20) III/19.2.1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 September 2023
Resolved 11 September 2023
Resolution: Vessel conducted training for all crew members assigned to the lifeboats. Personnel attended the vessel and questioned crew members and found their knowledge satisfactory.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 28 August 2023
Resolved
09298 - Cylinders (used for containing haxardous ships' stores that are compressed gases) must always be secured and, when not in use, they must be stowed in a rack in an upright position, with the valve protection cap in place. Multiple cylinders containing various compressed hazardous gasses were observed haphazardly secured on the secured on the aft mooring deck with rope or ratchet straps and not in racks. 46CFR 147.60(b)(1)
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 2 September 2023
Resolved 31 August 2023
Resolution: Vessel installed permanent brackets to properly stowe the bottles.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 28 August 2023
Resolved
11129 - Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in workingorde and ready for immediate use. Lifeboat #18 was found to have an inoperable VHF radio. Lifeboat #19 had a broken handrail. 74 SOLAS (20) III/20.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 28 August 2023
Resolved 28 August 2023
Resolution: VHF radio was replaced and broken handle was repaired by vessels crew.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 23 March 2023
Resolved
07123- Fire Safety - Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. 01 fire extinguisher and 1 semi portable fire extinguisher were blocked by vessel stores.
74 SOLAS 20 II-2/14.2.1.2
Action required: 10 - Deficiency Rectified
Resolved 23 March 2023
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 23 March 2023
Resolved
07123- Fire Safety- Structural fire protection, including fire-resisting divisions, and protection of openings and penetrations in these divisions, shall be kept in good order so as to ensure their required performance if a fire occurs. Fire door 5.036 was unable to close and latch due to a privacy curtains installed behind them.
74 SOLAS 20 II-2/14.2.1.1.1
Action required: 10 - Deficiency Rectified
Resolved 23 March 2023
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 23 March 2023
Resolved
07101 - Fire Prevention - In addition to complying with the specific provisions for fire integrity of bulkheads and decks of passenger ships, the minimum fire integrity of all bulkheads and decks shall be as prescribed in tables 9.1 and 9.2. Flammable liquid was observed being stored outside of a category 14 space.
74 SOLAS 20 II-2/9.2.2.3.1
Action required: 10 - Deficiency Rectified
Resolved 23 March 2023
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 23 March 2023
Resolved
02106 - Structural Conditions - The condition of the ship and its equipment shall be maintained to conform with the provision of the present regulations to ensure the ship in all respects will remain fit to proceed to sea. Lifeboat #18 was found to have a crack in structural frame supporting the cover of the vessel.
74 SOLAS 20 I/11
Action required: 10 - Deficiency Rectified
Resolved 23 March 2023
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 23 March 2023
Resolved
07105 - Fire Safety - The construction of doors and door frames in "A" class divisions, with the means of securing them when closed, shall provide resistance to fire as well as to the passage of smoke and flame equivalent to that of the bulkheads in which the doors are situated. Fire door leading into category 14 space was found to have a gap in excess of 25 mm at the bottom of the door.
74 SOLAS 20 II-2/9.4.1.1.2
Action required: 10 - Deficiency Rectified
Resolved 23 March 2023
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 3 April 2022
Resolved
Escape doors from public spaces that are normally latched shall be fitted with a means of quick release. Restaurants, lounges, and bars on deck 5 have twist locks in means of escape route.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 19 April 2022
Resolution: Twist locks were removed from escape routes in Category 8 spaces.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 4 October 2021
Resolved
Means of escape, including stairways and exits, shall be marked by lighting or photoluminescent strip indicators placed not more than 300 mm above the deck at all points of the escape route. the markings must enable passengers to identify the routes of escape and readily identify escape exits. corridor leading out of the hospital space has eight fixed chairs blocking the low location lighting.
Action required: 10 - Deficiency Rectified
Resolved 4 October 2021
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 October 2021
Resolved
Small enclosed rooms in a space that have less than 30% communicating openings to that space are considered separate spaces. joiner room between carpentry and upholstery rooms had its 30% communicating openings covered.
Action required: 10 - Deficiency Rectified
Resolved 4 October 2021
Construction/Loadline › Penetrations › Weld
Issued 10 February 2018
Resolved
The Administration shall satisfy itself that the general structural strength of the ship is adequate for the draught corresponding to the freeboard assigned. Multiple cracks were found in the outer tunnels of the three stern thrusters by divers originating in 2016. A recent crack was fount the inner tunnel of the stem thruster #3 causing minor water ingress, which has been permanently repaired. The crew, classification society and company have identified plans to repair the external cracks (50ab) **** Due to the nature of the damage and its location the above deficiency has been extended till the vessel's next dry dock February 2019.****
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 28 February 2019
Resolved 25 March 2019
Resolution: Vessel provided class report attesting to proper repairs of stern thrusters. See attached class doc.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Nozzles
Issued 1 October 2016
Resolved
Passenger ship shall be equipped w/an automatic sprinkler systm complying w/the requirements of the FSS Code, the number & arrangement of nozzles shall be such as to ensure an effective average distribution of water at least 5 liters per square meter. Multiple storage spaces had items stacked above max lvl required for nozzle to achieve required spray pattern. SOLAS 14/II-2/10.6.1.1 FSS 7/2.1.1.2
Condition: Placed in Improper Service
Due 1 October 2016
Resolved 1 October 2016
Resolution: Crew rectified the blocked nozzles on the spot allowing for proper spray pattern.