Records from 2019 to 2026. Most recent: inspection, 22 May 2026.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 March 2026
Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. PSCO observed sea water overboard piping that was fitted with a ball valve providing direct access to engine room space. This modification was not indicated on any ship approved drawings and presents a flooding hazard.
74 SOLAS (CON)
II-2/26.1
17ac
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 March 2026
Resolution: Received, reviewed and accepted class report from NKK stating the deficiency was rectified.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 March 2026
Resolved
Surfaces with temperatures above 220 degrees Celsius which may be impinged as a result of a fuel system failure shall be properly insulated. PSCO observed insulation removed from the turbo charger.
74 SOLAS (con)
II-2/4.2.2.6.1
17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 March 2026
Resolution: Received, reviewed and accepted class report from NKK stating the deficiency was rectified.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 March 2026
Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. PSCO observed insulation removed from steam piping above boiler feed water tank and replaced with aluminum foil.
74 SOLAS (CON)
II-1/26.1
17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 March 2026
Resolution: Received, reviewed and accepted class report from NKK stating the deficiency was rectified.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 3 March 2026
Resolved
Oil residue sludge tank shall be provided and the tanks may be fitted with drains, with manually operated self- closing valves and arrangements for subsequent visual monitoring of the settled water that lead to an oily bilge water holding tank or bilge well. PSCO observed a manually operated self closing valve with a bracket installed to defeat the self closing mechanism.
MARPOL Annex 1/12.3.3.1 10c
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 3 March 2026
Resolved 3 March 2026
Resolution: Crew removed bracket from valve.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 3 March 2026
Resolved
The company should establish procedures to ensure that the ship is maintained in accordance with the provisions of the relevant rules and regulations established by the company. the operational nature of the deficiencies noted above provide objective evidence of a serious failure of the implementation of the ISM code. An internal audit report satisfactory to the OCMI must be submitted within 90 days.
74 SOLAS (CON)
IX/3 ISM Code 10.1
ac
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 June 2026
Resolved 30 April 2026
Resolution: Received proper documentation from Panama satisfying the requirement.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 12 August 2019
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. Vessel arrived loaded with Alumina Hydrate, a group B, Hazardous in Bulk, Cargo not listed as an authorized cargo on the IMSBC certificate issued by NKK. 74 SOLAS (14) I/11 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 August 2019
Resolution: Vessel provided NKK report clearing the vessel to carry the cargo of Alumina Hydrate.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 12 August 2019
Resolved
All ships shall carry an up-to-date copy of Volume III of teh IAMSAR Manual. The vessel does not have the 2019 IAMSAR Manual onboard. 74 SOLAS (14) V/21.2
Action required: 10 - Deficiency Rectified
Resolved 12 August 2019
Resolution: Vessel received 2019 copy of IAMSAR onboard prior to end of exam.