HAPPY CAT

HAPPY CAT is a 2006 passenger vessel (inspected). The Coast Guard has recorded 16 inspections since 2016, most recently in June 2026, along with 63 deficiencies — 2 with no resolution recorded — and 2 operational controls.

Records from 2016 to 2026. Most recent: inspection, 24 June 2026.

Built
2006
Last inspected
24 June 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 24 June 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDD7380
860183
Flag
UNITED STATES
Maury page id
psix-860183

Documentation record

Registered dimensions (L × B × D)43.0 ft × 18.0 ft × 4.4 ft
Registered tonnagegross 10 / net 8
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBERNARD E EYMANN · KEY WEST, FL, UNITED STATES · built 2006
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationTwin Hull
Hailing portISLAMORADA, FL
Trade endorsementsFishery
DocumentationValid · issued 11 September 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it10 - Simplified, Gross Ton
8 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

16 inspections, each with its date, unit and type; 63 deficiencies with the resolution recorded against each; 2 operational controls with the dates imposed and removed; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 16

24 June 2026 Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8406194
24 February 2026 Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8317512
1 May 2025 Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8082114
5 February 2024 COI Inspection · Plan Review "T" Boat · Drydock Exam · Examination of Repairs · Internal Structural Exam · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7860489
17 May 2023 Examination of Repairs · Plan Review "T" Boat
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7689773
14 September 2022 Deficiency Check · Annual Inspection · Examination of Repairs · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7558558
2 February 2022 Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7387426
28 June 2021 DAPI Audit · Deficiency Check · Annual Inspection · Examination of Repairs
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7238242
29 June 2020 Administrative Inspection · DAPI Audit · Internal Structural Exam · Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6990456
16 January 2020 Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6888541
21 June 2019 Internal Structural Exam · COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6720861
6 September 2018 Annual Inspection · Administrative Inspection · Internal Structural Exam · DAPI Audit · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6661268
31 January 2018 Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6538947
26 September 2017 Damage Survey
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6294294
1 June 2017 Annual Inspection · Internal Structural Exam · DAPI Audit · Deficiency Check · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6295753
19 January 2016 Administrative Inspection · Internal Structural Exam · DAPI Audit · Annual Inspection · Drydock Exam · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5797984

Deficiency record · 63

11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 24 June 2026 Resolved
Life float is missing floating light.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 July 2026
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 June 2026 Resolved
New retro needs to be put on life jackets.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 July 2026
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 June 2026 Resolved
Label fire buckets.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 June 2026
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 24 June 2026 No resolution recorded
Drills need to be conducted.
Action required: 50 - Rectify deficiencies w/in 30 days
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 24 June 2026 No resolution recorded
DAPI/ Crew licenses/ charts/ FCC operators license must be submitted to MI.
Action required: 50 - Rectify deficiencies w/in 30 days
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 1 May 2025 Resolved
Missing Emergency instructions.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2025
Resolved 21 May 2025
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 1 May 2025 Resolved
Renew old and moldy first aid kit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2025
Resolved 21 May 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 May 2025 Resolved
Remount life jacket donning placard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2025
Resolved 21 May 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 May 2025 Resolved
Renew retro tape on 06 life jackets.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2025
Resolved 21 May 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 May 2025 Resolved
Renew retro tape on ring buoy.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2025
Resolved 21 May 2025
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 1 May 2025 Resolved
No deckhand present can not conduct drills, Drill log needs to be updated.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2025
Resolved 21 May 2025
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 4 March 2024 Resolved
EPIRB was currently going off and un able to stop it. Have EPIRP serviced or replace. Vessel is restricted to one mile from shore until cleared.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 April 2024
Resolved 23 April 2024
Resolution: EPIRB was sent out for servicing, tested SAT
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 March 2024 Resolved
Life float was missing one paddle. Replace missing paddle.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 April 2024
Resolved 23 April 2024
Resolution: 1 new paddel was added.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 4 March 2024 Resolved
FCC Safety Certificate was missing. Must show proof of valid FCC Safety Certificate.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 April 2024
Resolved 23 April 2024
Resolution: Showed valid FCC Safety Certificate
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 4 March 2024 Resolved
Several items were missing and or expired from first aid kit. Replace all missing or expired items.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 April 2024
Resolved 23 April 2024
Resolution: New first aid kit with CG approval number 160.041 was on board.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 3 October 2022 Resolved
Life float is damaged and needs repairs, painting and re labeling. Must conduct repairs, re painting and labeling to the satisfaction of attending CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2022
Resolved 22 November 2022
Resolution: Repainted life float.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 3 October 2022 Resolved
Life float floating water light is missing. Vessel is restricted to day light hours only until cleared by the CG.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2022
Resolved 22 November 2022
Resolution: Light back on board and working properly
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 3 October 2022 Resolved
Life float is missing both paddles. Must replace missing paddles that are 4 feet in length or extend to 4 feet, label with vessels name.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2022
Resolved 22 November 2022
Resolution: Two new paddles onboard and labeled with vessels name.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 3 October 2022 Resolved
Hydrostatic Release is expired. Must replace hydrostatic release.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2022
Resolved 22 November 2022
Resolution: New Hydrostatic release onboard.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 3 October 2022 Resolved
First Aid kit was missing several items. Must replace all missing items.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2022
Resolved 22 November 2022
Resolution: New first aid kit on board.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 October 2022 Resolved
Blade and glass fuses were found during the inspection. Fuses must be of the cartridge type only and be listed by Underwriters Laboratories (UL). Must replace all fuses with the UL approved cartridge type as discussed.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2022
Resolved 22 November 2022
Resolution: Replaced all fuses with correct ones.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 20 September 2022 Resolved
Vessel failed to conduct Annual inspection within the 180 day (90 day before and 90 day after anniversary date of June 21st) window. Vessel must conduct annual inspection prior to carrying passengers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 October 2022
Resolution: Conducted annual inspection
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 2 February 2022 Resolved
Port quarter suffered damage to outer layers of FRP from a docking evolution. Damage is in a 4”x4” area with FRP removed and cracked to the foam core. Grind and renew to original layup.
Action required: 705 - Other - as specified
Resolved 8 February 2022
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 2 February 2022 Resolved
Identified a 10” crack in exterior layers of the FRP on the starboard side approx. midships. FRP is cracked to the foam core. Grind and renew to original layup.
Action required: 705 - Other - as specified
Resolved 8 February 2022
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 30 June 2021 Resolved
High water bilge alarm on STBD side not working. Must make repairs and test with CG Marine Inspector prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 July 2021
Resolved 8 July 2021
Resolution: Vessel made repairs, tested SAT.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 30 June 2021 Resolved
VHF radio was not working. Must make repairs and test to satisfaction of attending CG Marine Inspector. Vessel is registricted to 3 miles from shore.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 July 2021
Resolved 8 July 2021
Resolution: Installed new radio, test SAT
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 30 June 2021 Resolved
Life float is faded and needs repainting.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 July 2021
Resolved 9 September 2021
Resolution: Painted life float
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 June 2021 Resolved
Life ring buoy needs vessels name put on.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 July 2021
Resolved 9 September 2021
Resolution: Painted vessels name on life ring
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 June 2021 Resolved
Life ring buoy floating light is not working. Must make repairs or replace light. Vessel is registricted to day light hours only.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 July 2021
Resolved 8 July 2021
Resolution: Replaced floating light, test SAT
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 30 June 2021 Resolved
Alcohol swabs were expired. Must replace with enough to test entire crew in the event a Marine Casualty.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 July 2021
Resolved 9 September 2021
Resolution: New swabs ordered with experation date of 06-30-2022
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 30 June 2021 Resolved
First aid kit had expired items. Must replace expired items.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 July 2021
Resolved 9 September 2021
Resolution: Replaced missing items, all SAT
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 30 June 2021 Resolved
Both MDE guards around pulleys/belts are missing. Must replace missing guards. **update** Vessel is due for drydock winter of 2021/2022. Vessel will have new engine guards fab'ed during drydock.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 July 2021
Resolved 8 February 2022
Resolution: Rotating machinery guards have been installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 30 June 2021 Resolved
All water tight bulkhead penetrations needs re sealing. Must use CG approved sealant to seal all bulkhead penetrations to make water tight.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 July 2021
Resolved 9 September 2021
Resolution: Sealed all watertight bulkheads with fire stop sealant.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 29 June 2020 Resolved
All flares are expired. Renew with 12 red or 6 red and 6 orange flares.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 June 2020
Resolved 29 June 2020
Resolution: Owner purchased 12 red flares and placed it on the vessel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 June 2020 Resolved
First aid kit contents are expired. Renew kits or content. (Life boat kit).
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2020
Resolved 17 July 2020
Resolution: Brand new First Aid Kit that Meats CG criterial was purchased and placed on board.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 29 June 2020 Resolved
Ring buoy needs repairs. Renew line, name, and reflective material.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 July 2020
Resolved 17 July 2020
Resolution: Ring buoy effectively renewed the reflective material.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 29 June 2020 Resolved
Starboard engine room bilge doesn’t operate in auto. Repair/Renew.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 July 2020
Resolved 17 July 2020
Resolution: Auto bilge pump was purchase andproperly installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 June 2020 Resolved
Life jackets need new reflective material.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 July 2020
Resolved 17 July 2020
Resolution: Life jacket reflective tape was renewed.
14 - Pollution Prevention › 145 - MARPOL Annex V › Placards
Issued 29 June 2020 Resolved
MARPOL Placard needs to be posted.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 July 2020
Resolved 17 July 2020
Resolution: MARPOL Placard was purchased, renewed and posted.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 29 June 2020 Resolved
Fire extinguishers need annual inspection.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 July 2020
Resolved 17 July 2020
Resolution: Fire extinguishers were inspected.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 16 January 2020 Resolved
Grind down identified areas on hull to good glass and conduct repairs. Two areas on Port hull were found damaged/delaminated.
Action required: 705 - Other - as specified
Resolved 28 February 2020
Resolution: Hull repairs properly completed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 January 2020 Resolved
Replace Port shaft bearing (cutlass), bearing rubber was found damaged/detached from housing.
Action required: 705 - Other - as specified
Resolved 28 February 2020
Resolution: Both cutlass bearings replaced
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 16 January 2020 Resolved
Install all watertight hatch covers and make vessel available for re-inspection. Covers were removed to rebuild gaskets and latches.
Action required: 705 - Other - as specified
Resolved 28 February 2020
Resolution: All gaskets replaced
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 21 June 2019 Resolved
STBD engine room fire boy does not secure engine. Repair/Renew no later than 27Jun2019.
Action required: 705 - Other - as specified
Due 27 June 2019
Resolved 27 June 2019
Resolution: Fire Boy tech assessed the system and corrected the discrepency. All Sat.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 21 June 2019 Resolved
Aft navigation light needs new cover and bulb.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 June 2019
Resolution: Aft navigation light was replaced, verified. All Sat.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 21 June 2019 Resolved
Vessel required to carry 3 2.5 gallon fire buckets. Provide.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 June 2019
Resolution: 03 2.5 gallon fire buckets have been been placed on the vessel, and verified.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 21 June 2019 Resolved
Repaint and Rename life float.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 July 2019
Resolution: Life float has been repainted and named on both sides.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 21 June 2019 Resolved
Captain must have FCC Radio operators permit. Provide.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 July 2019
Resolution: Provided
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 6 September 2018 Resolved
Life float must be overhauled, renew lines, provide paddles, repair cracks, and paint.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 October 2018
Resolution: Repaired
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 6 September 2018 Resolved
Port and stbd navigation light lense are damaged, and must be renewed.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 October 2018
Resolution: Renewed
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 September 2018 Resolved
PFD's need new reflective material.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 October 2018
Resolution: Renewed
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 6 September 2018 Resolved
Required logs are not maintained. Provide log for drills, EPIRB tests, and survival craft maintenance.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 October 2018
Resolution: Provided
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 September 2018 Resolved
First aid kit is incomplete, renew.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 October 2018
Resolution: Renewed
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 6 September 2018 Resolved
Horn is not operating correctly. Repair or renew.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 October 2018
05 - Radio Communications › N/A - No Subsystem › Performance standards for radio equipment
Issued 6 September 2018 Resolved
Link VHF to GPS, input MMSI number.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 October 2018
Resolution: Linked
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 September 2018 Resolved
Fire extinguisher must be inspected annually. Provide proof of inspection.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 October 2018
Resolution: Inspected
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 September 2018 Resolved
BI fire extinguisher has been recalled. Provide new extinguisher.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 October 2018
Resolution: New extinguisher provided.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 6 September 2018 Resolved
All hatch seals are damaged. Repair hatches and seals.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 October 2018
Resolution: Repaired
Communications › Alarms/Indicators › High Water Alarm
Issued 1 June 2017 Resolved
High water visual alarm is extinguished. Repair/renew.
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 15 June 2017
Resolution: NEw bulb was installed and tested all sat.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 1 June 2017 Resolved
Fuel fill is not grounded.
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 15 June 2017
Resolution: Ground wires were installed.
Electrical › Electric Supply System (service) › Battery Installation
Issued 1 June 2017 Resolved
Battery under helm console is not in a protected box. provide battery box.
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 15 June 2017
Resolution: Battery Box was provided and battery is now protected.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 1 June 2017 Resolved
All Navigation publications are expired. Renew.
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 15 June 2017
Resolution: New publications were provided.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 1 June 2017 Resolved
Fire extinguisher service is expired and must be completed.
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 15 June 2017
Resolution: Inspection was completed.