Records from 2016 to 2025. Most recent: inspection, 22 December 2025.
Inspection history · 30
22 December 2025
CCSSC Examination · PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8283557
20 August 2025
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8219915
9 June 2025
CCSSC Examination · PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8155397
22 November 2024
PSC B · CCSSC Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8018680
11 April 2024
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7891108
11 March 2024
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7873018
2 September 2023
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7775559
10 February 2023
Administrative Inspection · PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7634054
4 August 2022
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7524540
15 March 2022
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7412065
25 January 2022
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7385457
21 July 2021
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7263067
22 April 2021
PSC B · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7175051
16 October 2020
PSC B · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7077174
28 September 2020
Deficiency Check · PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7066824
8 September 2020
Administrative Inspection · PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7052806
21 January 2020
Ballast Water Examination · PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6893135
4 December 2019
ISPS II Exam · Deficiency Check · Ballast Water Examination · CCSSC Examination · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6866910
18 October 2019
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6837272
6 June 2019
Ballast Water Examination · ISPS II Exam · PII Safety Exam · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6705187
6 December 2018
NPV Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6592736
6 June 2018
ISPS III Exam · CCSSC Examination · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6435121
6 December 2017
CCSSC Examination · MTSA Verification · Deficiency Check · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6318664
7 June 2017
Ballast Water Examination · CCSSC Examination · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6168159
13 December 2016
CCSSC Examination · MTSA Verification · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6057221
13 October 2016
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6021982
7 July 2016
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5932362
7 July 2016
Administrative Inspection · In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5933602
20 June 2016
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5913677
17 January 2016
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5798982
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 22 November 2024
Resolved
A ship except a ship of less than 26 feet in length, must have a placard of at least 5 by 8 inches, made of durable material fixed in a conspicuous place in each machinery space or at the bilge and ballast pump control station. PSCOs did not observe an oil discharge placard in the machinery space or at the bilge and ballast station.
33 CFR 155.450(a)
Code 10c
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 22 November 2024
Resolved 22 November 2024
Resolution: Rectified on the spot.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 11 March 2024
Resolved
The regulations of chapter V of the 1974 SOLAS Convention apply, as appropriate, to all ships to which this code applies, in particular: .16 regulation 20 Nautical Publications: All ships shall carry adequate and up-to-date charts.
PSCOs observed 03 years of missing chart corrections on chart 11468.
CCSSC (97) Ch 6 Reg. 6.1.2.16
74 SOLAS Ch 5 Reg. 20
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 March 2024
Resolution: Vessel purchased and has onboard new charts with updated corrections.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 10 February 2023
Resolved
Every ship of 100 gross tonnage... shally carry a garbage management plan... this plan shall provide written procedures for minimizing, collecting, storing, processing, and disposing of garbage. PSCO's observed no procedures specific to the ship or how they intend to be in compliance.
2017 MARPOL ANNEX V/10.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 March 2023
Resolved 27 February 2023
Resolution: Vessel produced an adequate revision of the Garbage Management Plan
12 - Dangerous Goods › N/A - No Subsystem › Special requirement
Issued 25 January 2022
Resolved
Ships intended for the carriage of dangerous goods shall comply with the special requirements as specified in Chapter II-2 of the 1974 SOLAS Convention...Arrangements shall be made to ensure immediate availability of a supply of water from the fire main at the required pressure...by suitably placed remote arrangements for the fire pumps.
Emergency fire pump has no remote start up arrangements.
CCSSC 3.25.1
74 SOLAS 20 cons. II-2/19.3.1
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 February 2022
Resolved 15 March 2022
Resolution: Recieved Flag and class report attesting to the instulation and operatin of new EFP with automatic remote start.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 22 April 2021
Resolved
All fire protection systems and appliances shall at all times be in good order. PSCO observed significant wastage on the time delay cylinder , and hose connections were found with significant rust built up.
CCSC 3.6.12
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 April 2021
Resolution: Vessel provided Flag Letter addressing correction of written deficiency. Photographs and service report provided informing of replacement of time delay cylinder. All documents uploaded.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 29 September 2020
Resolved
All fire protection systems and appliances shall at all times be in good order and available for immediate use while the ship is in service.. Fire detection panel on the bridge has a fault in the system. 02 detectors failed to indicate or alarm locally and in bridge when tested.
CCSS Code 3.6.12
Action required: 10 - Deficiency Rectified
Resolved 1 October 2020
Resolution: PSCOs witness satisfactory test of 03 heat detectors in engine room and notification on fire panel in the bridge without showing any fault.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 September 2020
Resolved
The table requires a minimum of 06 lifebuoy's that shall comply with the code... 02 lifebuoys maintained a permanent knot in the unapproved buoyant lifeline.
CCSS Code 4.12.1
Action required: 10 - Deficiency Rectified
Resolved 1 October 2020
Resolution: PSCOs verified life buoys replacements were in compliance with LSA code.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 8 September 2020
Resolved
Each operation described in paragraph 2 of this regulation shall be fully recorded without delay in the Oil Record Book Part I so that all entries in the book appropriate to that operation are completed...Sludge receipts dated 06FEB2020, 27FEB2020, and 05MARCH2020 have no corresponding entries in the oil record book.
MARPOL I/17.4
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 September 2020
Resolution: Deficiency rectified by Chief Engineer updating the Oil Record Book to include the missing entries.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil and oily mixtures from machinery spaces
Issued 8 September 2020
Resolved
The oil residues which cannot be discharged into the sea in compliance with this regulation shall be retained on board for subsequent discharge to reception facilities... Oil Record Book entries for discharge ashore dated 12AUG2020 and 19AUG2020 have no corresponding sludge receipts.
MARPOL I/15.9
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 September 2020
Resolution: Deficiency rectified by the facility providing the correct sludge receipts and adding them to the ship's binder while onboard.
04 - Emergency Systems › N/A - No Subsystem › Emergency steering position com./ compass reading
Issued 8 September 2020
Resolved
Ships shall comply with the following requirements of SOLAS Chapter V as they apply in relation to a ship of its description. All ships officers concerned with the operation and/or maintenance of steering gear shall be familiar with the operation of the steering systems fitted on the ship...Vessel's Chief Engineer was not familiar with the operational controls for emergency steering and could not operate it in a timely manner.
CCSSC Ch 6/Reg 6.5
74 SOLAS (14) V/26.3.2
Action required: 10 - Deficiency Rectified
Resolved 8 September 2020
Resolution: Chief Engineer was eventually able to start the emergency steering with prompting.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 21 January 2020
Resolved
Every liferaft shall be stowed with its painter permanently attached to the ship and with a flat-free arrangement so that the liferaft floats free and, if inflatable, inflates automatically when the ship sinks. PSCO's observed the painter on the port side liferaft was not properly connected to the weak link. CSCCS (2018) 4.9.5
Action required: 10 - Deficiency Rectified
Due 22 January 2020
Resolved 22 January 2020
Resolution: Crew member adjusted the location of the painter to the weak link in front of PSCO's.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 4 December 2019
Resolved
The owner of or the master of every ship to which this code applies shall ensure that the condition of the ship and its equipment is maintained to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship, persons on board or the environment. Fixed emergency fire pump space filled with smoke upon starting and continued to do so until personnel entered the space by donning breathing device to stop the motor. representing a danger to the ship and persons on board. CCSSC CH 1.11.1 17BC
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 December 2019
Resolution: Received Attestation Letter from flag state stating deficiency has been corrected. Chief Engineer found that the emergency fire pump had detached clamp on the flexible exhaust. The clamp was replaced. Pump was tested and found functioning properly.
01 - Certificates & Documentation › 013 - Documents › Fire control plan - all
Issued 4 December 2019
Resolved
All ships shall be proved with a fire control plan to the satisfaction of the Administration. The exhibited fire control plan is not approved by the Administration and is not indicated as being issued for this vessel. Fire control plan does not have "A" Class fire boundaries indicated around machinery space. CCSSC Ch.3.13 16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 December 2019
Resolved 23 December 2019
Resolution: Flag attestation recieved and reviewed for updated and approved plan.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 December 2019
Resolved
Vessels shall conduct qualified individual notification exercises which must be conducted quarterly. Ship had no record of qualified individual drills. Crew did not recognize or know the Q.I. number. 33CFR155.1060(a)(1) 10c
Action required: 10 - Deficiency Rectified
Resolved 4 December 2019
01 - Certificates & Documentation › 012 - Crew Certificates › Manning specified by the minimum safe manning doc
Issued 18 October 2019
Resolved
EACH ADMINISTRATION SHALL...HOLD COMPANIES FOR THE ASSIGNMENT OF SEAFARERES FOR SERVICE ON THEIR SHIPS....TO ENSURE THAT....ITS SHIPS ARE MANNED IN COMPLIANCE WITH THE APPLICABLE SAFE MANNING REQUIREMENTS OF THE ADMINISTRATION. THE VESSEL IS PROVIDED A MINIMUM SAFE MANNING DOCUMENT FROM THE REPUBLIC OF PANAMA THAT REQUIRES THE VESSEL TO OPERATE WITH A CHIEF AND SECOND ENGINEER, BOTH CERTIFIED IN ACCORDANCE WITH THE MINIMUM REQUIREMENTS OF CHAPTER III/3 OF STCW. THE SECOND ENGINEER ONBOARD COULD PRODUCE A CERTIFICATE ATTESTING TO THE MINIMUM REQUIREMENTS OF III/I. THE VESSEL ENTERED COTP ZONE MIAMI ON 18OCT19 WITH ONLY ONE MARINER POSESSING THE CORRECT CERTIFICATION FOR III/3. WHILE IN PORT, THE VESSEL OBTAINED A NEW SECOND ENGINEER MEETING THE REQUIREMENTS OF III/3 AS SPECIFIED ON THE MANNING REQUIREMENT. 78 STCW (2017 CONS.) REG 1/14.1.2
Action required: 10 - Deficiency Rectified
Due 18 October 2019
Resolved 18 October 2019
Resolution: VESSEL HAD A NEW ENGINEER REPORT TO THE SHIP WITH THE CORRECT CERTIFICATIONS.
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 6 June 2019
Resolved
14101 - Pollution Prevention - Oil residue may be disposed of directly from oil residue tanks through the standard discharge connection or any other approved means of disposal. Ships IOPP Supplement Form "A" stated that the ship was fitted with a standard discharge connection; however, the ship could not provide the standard discharge connection for inspection. - MARPOL (2014) Annex I Reg. 12.2.
Action required: 10 - Deficiency Rectified
Due 20 June 2019
Resolved 25 June 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 6 June 2019
Resolved
01199 - Certificates & Documentation - Vessels greater than or equal to 300 GT must submit a signed and certified, complete and accurate Notice of Intent (NOI) in accordance with the requirements of appendix E. Ship could not provide electronic or paper copy of NOI and the ship has not submitted annual reports. - 2013 VGP 1.5.1.1
Action required: 10 - Deficiency Rectified
Due 20 June 2019
Resolved 25 June 2019
04 - Emergency Systems › N/A - No Subsystem › Shipboard Marine Pollution emergency operations
Issued 6 June 2019
Resolved
04112 - Emergency Systems - Vessels shall conduct qualified individual notification exercises which must be conducted quarterly. Ship could not provide evidence of qualified individual notification drills being conducted.
Action required: 10 - Deficiency Rectified
Resolved 6 June 2019
Resolution: Master of the vessel conducted a QI notification while PSC team was on board and recorded drill in the ship's log.
Fire Fighting › Fire Pumps › Pressure
Issued 6 June 2018
Resolved
0740- The main fire pump shall be capable of delivering for internal firefighting purposes on board. Main fire pump has a ruptured bleed valve rendering the fire pump inoperable-ccssc (2015) ch.3.3.2
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 9 June 2018
Resolved 8 June 2018
Resolution: Bleed valve was replaced and in working condition
Fire Fighting › Fixed CO2 Fire Extinguishing System › Quantity of CO2
Issued 6 June 2018
Resolved
0725- In every ship, one of the fixed fire extinguishing systems referred to in 3.10.1 shall be provided for the protection of any space containing internal combustion type machinery. CO2 system on board is not operational due to repair. CCSSC (2015) ch. 3.10.3
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 9 June 2018
Resolved 8 June 2018
Resolution: CO2 lines and pull stations have been replaced
Personnel › Training › Fire Fighting Basic
Issued 6 December 2017
Resolved
CCSSC (2015 rev.) 4/4.17.5 - Each crew member shall be familiar with the use of the ship's lifesaving appliances, including survival craft equipment, fire-fighting equipment, and emergency procedures before a voyage begins. Crew was not familiar with firefighting equipment used on board.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 December 2017
Resolved 8 December 2017
Resolution: Received flag attestation and witnessed donning/operation of the equipment.
Documentation › Markings/Placards › Warning Signs
Issued 6 December 2017
Resolved
74 SOLAS (14 consolidated)V/26.3.1 - Simple operating instructions with a block diagram showing the change over procedures for remote steering gear control systems and steering gear power units shall be permanently displayed on the navigation bridge and in the steering compartment. Vessel did not have a block diagram of steering gear arrangement.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 December 2017
Resolved 8 December 2017
Resolution: Sighted block diagram.
Operations/Management › Drills/Instruction › Not Conducted
Issued 6 December 2017
Resolved
CCSSC (2015 Rev.) The Master shall ensure that the frequency of enclosed space drills shall not exceed quarterly. Crew has not done drills.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 December 2017
Resolved 8 December 2017
Resolution: Sighted record of drills for confined space entry with calibrated equipment and updated drill schedule.
Lifesaving › Hand Flares › Approval
Issued 7 June 2017
Resolved
0640-Distress Flares- Every ship shall be provided with no less than six hand held red flare signals. Vessel had only recreational use hand held red flare signals on board. CCSSC Ch 4.14
Action required: 705 - Other - as specified
Due 7 June 2017
Resolved 7 June 2017
Resolution: Agent brought SOLAS approved hand held signal flares to the vessel in the required quantities.
Pollution Prevention/Response › Prevention Equipment › Annex VI
Issued 21 June 2016
Resolved
EVERY SHIP OF 100 GROSS TONS AND ABOVE SHALL CARRY A GARBAGE MANAGEMENT PLAN WHICH THE CREW SHALL FOLLOW. THE CREW IS NOT FOLLOWING THE PLAN. FOOD WASTE NOT COMMUTED OR GROUND IS BEING DISCHARGED BETWEEN 3-12 NAUTICAL MILES FROM NEAREST LAND ACCORDING TO DESIGNATED PERSON IN CHARGE. VESSEL DOES NOT HAVE A GRINDER, THEREFORE PER VESSEL'S PLAN, ALL FOOD WILL BE STORED AND DISCHARGED AT NEXT PORT.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 June 2016
Resolution: Attended vsl, verified Flag/Class reports, cleared def.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 21 June 2016
Resolved
EVERY SHIP OF 400 GROSS TONS AND ABOVE SHALL BE PROVIDED WITH A GARBAGE RECORD BOOK. EACH DISCHARGE TO THE SEA OR TO A RECEPTION FACILITY SHALL BE PROMPTLY RECORDED, SIGNED BY THE MASTER, AND INCLUDE POSITION OF THE SHIP. VESSEL IS NOT COMPLETING RECORD BOOK ENTRIES PROPERLY-NO SHIP POSITION IS LISTED FOR DISCHARGE OF FOOD SINCE 4MAR2015, RECEPTION FACILITY RECEIPTS DO NOT MATCH RECORD BOOK, MASTE
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 June 2016
Resolution: Attended vsl, verified flag/class reports, cleared def.
Engineering › Sea-water System (primary cooling) › Piping
Issued 21 June 2016
Resolved
CCSSC CH 2 / REG 2.30.2.1.3: MEANS SHOULD BE PROVIDED WHEREBY NORMAL OPERATIONS OF PROPULSION MACHINERY CAN BE SUSTAINED OR RESTORED EVEN THOUGH ONE OF THE ESSENTIAL AUXILIARIES BECOMES INOPERATIVE. SPECIAL CONSIDERATIONS SHOULD BE GIVEN TO THE MALFUNCTIONING OF SOURCES OF WATER PRESSURE. COOLING LINES ON THREE PRIME MOVERS FOUND LEAKING AND IMPROPERLY REPAIRED.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 July 2016
Resolved 7 July 2016
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 21 June 2016
Resolved
CCSSC CH 2 / REG 2.16.2: MOVING PARTS OF MACHINERY WHICH ARE SO EXPOSED AS TO CAUSE ACCIDENTS SHOULD BE PROPERLY GUARDED. EXPOSED PORTIONS OF BOTH PORT AND STARBOARD SIDE PRIME MOVERS FOUND UNGUARDED.
Action required: 705 - Other - as specified
Due 5 July 2016
Resolved 7 July 2016
Documentation › Logs/Records › Ballast Water Reporting Form
Issued 21 June 2016
Resolved
THE MASTER, OWNER, OPERATOR, AGENT OR PERSON IN CHARGE OF A VESSEL MUST PROVIDE BALLAST WATER REPORTING FORMS TO THE NATIONAL BALLAST INFORMATION CLEARINGHOUSE AT LEAST 24 HOURS PRIOR TO ARRIVAL AT U.S. PORTS OR PLACE OF DESTINATION. PERSON IN CHARGE OF SUBMITTING REPORTS DID NOT SUBMIT REPORTS AS REQUIRED.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 7 July 2016