Records from 2006 to 2023. Most recent: inspection, 28 September 2023.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 7
28 September 2023
PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7792706
11 November 2019
ISPS II Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6850388
12 December 2017
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6316777
26 October 2016
Deficiency Check · PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6027793
24 November 2010
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3895310
23 October 2006
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2806214
19 October 2006
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2804227
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 26 October 2016
Resolved
ALL SHIPS 300GT AND UPWARDS SHALL BE FITTED WITH AN ECHO-SOUNDING DEVICE, OR OTHER ELECTRONIC MEANS, TO MEASURE AND DISPLAY THE AVAILABLE DEPTH OF WATER. THE ECHO-DEPTH SOUNDER COULD NOT CONSISTENTLY DISPLAY THE DEPTH OF WATER. 74SOLAS(2014 cons.)V/19.2.2.3.1 Action taken: 17c
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 October 2016
Resolution: Received technician's report rectifying the deficiency for the echo-depth sounder. Report placed in docs.
Operations/Management › Drills/Instruction › Not Conducted
Issued 26 October 2016
Resolved
CREW MEMBERS WITH ENCLOSED SPACE ENTRY OR RESCUE RESPONSIBILITIES SHALL PARTICIPATE IN AN ENCLOSED SPACE AND RESCUE DRILL TO BE HELD ON BOARD THE SHIP AT LEAST ONCE EVERY TWO MONTHS. ENCLOSED SPACE DRILL IS 23 DAYS OVERDUE. 74SOLAS(2014 cons.)III/19 Action taken: 17c
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 October 2016
Resolution: Received record of enclosed space drill being conducted as well as pictures. Both placed in docs.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 23 October 2006
Resolved
Emergency lighting not operating at lifeboat embarkation station.
Action required: 705 - Other - as specified
Resolved 23 October 2006
Resolution: Emergency lighting fixed.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 23 October 2006
Resolved
Port side lifeboat station life buoy light inoperable.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 October 2006
Resolution: Replaced by crew.
Lifesaving › Lifebuoys › Immediately Available
Issued 23 October 2006
Resolved
Numerous life buoys restrained from float free arrangement.
Action required: 705 - Other - as specified
Resolved 23 October 2006
Resolution: Life buoys now float free.
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 23 October 2006
Resolved
Port side liferaft hydrostatic release not properly marked, unable to determine when device was place in service.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 October 2006
Resolution: Service dates were remarked.
Fire Fighting › Fire Hoses › Condition
Issued 23 October 2006
Resolved
Fire hose containment box was found with additional securing straps applied, preventing swift access to fire hose.
Action required: 705 - Other - as specified
Resolved 23 October 2006
Resolution: Removed additional strapping.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 23 October 2006
Resolved
Fire doors not performing self closure.
Action required: 705 - Other - as specified
Resolved 23 October 2006
Resolution: Found to be operating properly.