Records from 2016 to 2020. Most recent: inspection, 25 June 2020.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 25 June 2020
No resolution recorded
Vessel has let COI lapse; expiration dates was 07APR2020. Vessel cannot operate under COI until satisfactory COI inspection is complete.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 August 2019
Resolved
Lifering not readily accessible
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 August 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 August 2019
Resolved
Life jackets not readily accessible
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 August 2019
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 6 August 2019
Resolved
Inoperable high level bilge alarm
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 August 2019
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 6 August 2019
Resolved
Secure loose vent closure flange with bolts
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 August 2019
02 - Structural Conditions › N/A - No Subsystem › Bulkhead strength
Issued 2 July 2018
Resolved
Found hole in watertight bulkhead between collision bulkhead and machinery space. Crew sealed with 5200, corrected on the spot.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 2 July 2018
Resolved 2 July 2018
Resolution: Corrected on the spot
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 2 July 2018
Resolved
Forward high water alarm inoperable. High water alarm lights do not correspond to associated spaces. Repair/Replace to the satification of the attending MI.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 July 2018
Resolved 18 July 2018
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 2 July 2018
Resolved
Dead end wires in berthing area and head space. Remove or place in appropriate junction box.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 July 2018
Resolved 18 July 2018
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 2 July 2018
Resolved
No charts for operating area. Provide up to date charts.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 July 2018
Resolved 18 July 2018
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 2 July 2018
Resolved
Vessel's log books were missing and when found were not made up to date. Provide books with new entries for maintenance and training/drills.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 July 2018
Resolved 18 July 2018
Lifesaving › Lifefloat › Markings
Issued 5 July 2017
Resolved
Make repairs to life float, clean, install SOLAS retro-tape, label max passengers IAW 185.604.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 August 2017
Resolved 29 September 2017
Resolution: Liferaft was repaired
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 5 July 2017
Resolved
Obtain alcohol test strips IAW 46 CFR16.240
Condition: Invalid
Action required: 705 - Other - as specified
Due 5 August 2017
Resolved 28 September 2017
Resolution: Alcohol strips were provided.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 5 July 2017
Resolved
FCC safety certificate is expired, renew IAW 46 CFR 184.420
Condition: Invalid
Action required: 705 - Other - as specified
Due 5 August 2017
Resolved 28 September 2017
Resolution: Vessel operator was able to get FCC safety cert.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 5 July 2017
Resolved
Obtain smoke detector alarms and install IAW 46 CFR 181.400
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 August 2017
Resolved 28 September 2017
Resolution: Smoke detector was placed and working in accomidation space.
Communications › Alarms/Indicators › Bilge Alarm
Issued 5 July 2017
Resolved
Label high water and bilge lights on console IAW 46 CFR 182.530
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 5 August 2017
Resolved 28 September 2017
Resolution: Items were all labeled on the console.
Communications › Radio Communications › VHF Radiotelephone
Issued 5 July 2017
Resolved
Make DSC GPS operable IAW 47 CFR 80 & 46 CFR 184.520
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 August 2017
Resolved 28 September 2017
Resolution: DSC to GPS on the VHF radio was installed and working.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 5 July 2017
Resolved
Conduct emergency drills and log IAW 46 CFR 185.520
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 August 2017
Resolved 28 September 2017
Resolution: Drills being conducted quarterly.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 5 July 2017
Resolved
Obtain current navigation pubs and charts IAW 184.420
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 August 2017
Resolved 28 September 2017
Resolution: Charts and pubs were provided electronically with additional backup.
Engineering › Fuel Oil Service System › Filter
Issued 5 July 2017
Resolved
Replace raycor filter drain with plug type IAW 46 CFR 182.455
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 August 2017
Resolved 28 September 2017
Resolution: Plug was installed on bottom of raycor fuel filter bowl.
Construction/Loadline › Hull › Bracket
Issued 5 July 2017
Resolved
Clean around tanks, shown during exam, secure bonding wires IAW 46 CFR 176.800
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 August 2017
Resolved 28 September 2017
Resolution: Area was cleaned and wire was bonded.
Communications › Radio Communications › Satellite Communications Capability
Issued 5 July 2017
Resolved
Post exception letter for SAT phone IAW 47 CFR 80.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 August 2017
Resolved 28 September 2017
Resolution: Vessel was able to obtain FCC safety certificate, alleviating the need for sat phone.
Communications › Radio Communications › EPIRB
Issued 6 July 2016
Resolved
EPIRB Hydrostatic release must be renewed. Vessel cannot operate beyond 3 miles.
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 July 2016
Resolved 26 July 2016
Resolution: Replaced hydrostatic release
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 6 July 2016
Resolved
Alcohol testing strips not present. Vessel must remain with 2 hours of shore.
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 July 2016
Resolved 26 July 2016
Resolution: Approved testing devices provided.
Communications › Alarms/Indicators › Bilge Alarm
Issued 6 July 2016
Resolved
All high water visual alarms inoperative; lazarette and engine room float switches inop. Crewmembers must conduct and log visual inspections every 20 min. when underway.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 July 2016
Resolved 26 July 2016
Resolution: Indicator operating correctly
Fire Fighting › Remote Fuel Shutoff › General
Issued 6 July 2016
Resolved
Starboard emergency fuel shut-off handle must be replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 July 2016
Resolved 26 July 2016
Resolution: Handle replaced.
Engineering › Bilge Water Management System › Pump
Issued 6 July 2016
Resolved
Vessel does not have portable hand bilge pump. Provide portable hand bilge pump.
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 July 2016
Resolved 26 July 2016
Resolution: Hand pump provided.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 6 July 2016
Resolved
Required EAP Supervisor training not completed. Provide certificate of completion.
Condition: Invalid
Action required: 705 - Other - as specified
Due 10 August 2016
Resolved 31 August 2016
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 6 July 2016
Resolved
Post EAP hotline number for crewmembers and provide EAP policy for vessel.
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 July 2016
Resolved 26 July 2016
Resolution: EAP hotline posted
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 6 July 2016
Resolved
Crewmembers not listed on DAPI letter. Provide documentation of policy enrollment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 August 2016
Resolved 30 August 2016
Documentation › Safety/Response Plans/Programs › Waste Management Plan
Issued 6 July 2016
Resolved
Waste management plan not posted. Ensure waste management plan is posted.
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 July 2016
Resolved 26 July 2016
Resolution: Waste management plan posted
Navigation › Piloting/Steering › US Coast Pilot
Issued 6 July 2016
Resolved
Vessel could not provide current Coast Pilot. Provide current Coast Pilot for area.
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 July 2016
Resolved 26 July 2016
Resolution: Current Coast Pilot provided
Documentation › Certificates/Documents › Certificate of Inspection
Issued 6 July 2016
Resolved
COI not posted in a visible space for observation by passengers.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 July 2016
Resolved 26 July 2016
Resolution: COI posted
Lifesaving › Liferaft Equipment › First-aid Kit
Issued 6 July 2016
Resolved
First aid kid items expired. Provide current items in first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 July 2016
Resolved 26 July 2016
Resolution: Expired items replaced.
Lifesaving › Emergency Outfit › Flashlight
Issued 6 July 2016
Resolved
Portable light (flashlight) must be located at the access to the engine room.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 July 2016
Resolved 26 July 2016
Resolution: Flashlight provided outside of engine space access.
Documentation › Certificates/Documents › Permit, Other
Issued 6 July 2016
Resolved
All masters aboard vessel must provide current FCC Marine Radio Operator permit.
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 July 2016
Resolved 26 July 2016
Resolution: Provided valid permit
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 6 July 2016
Resolved
MSD holding tank valve must be locked at all times within 3 miles of shore.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 July 2016
Resolved 26 July 2016
Resolution: MSD locked in closed position
Fire Fighting › Means of Escape › Emergency Lighting
Issued 6 July 2016
Resolved
Vessel's emergency lighting must automatically actuate upon failure of main lighting system. Vessel may not embark on overnight trips until corrected.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 July 2016
Resolved 26 July 2016
Resolution: Emergency lighting operated correctly