Records from 2007 to 2020. Most recent: inspection, 25 June 2020.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 25 June 2020
No resolution recorded
Vessel has let COI lapse; expiration dates was 07APR2020. Vessel cannot operate under COI until satisfactory COI inspection is complete.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 August 2019
Resolved
Lifering not readily accessible
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 August 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 August 2019
Resolved
Life jackets not readily accessible
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 August 2019
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 6 August 2019
Resolved
Inoperable high level bilge alarm
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 August 2019
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 6 August 2019
Resolved
Secure loose vent closure flange with bolts
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 August 2019
02 - Structural Conditions › N/A - No Subsystem › Bulkhead strength
Issued 2 July 2018
Resolved
Found hole in watertight bulkhead between collision bulkhead and machinery space. Crew sealed with 5200, corrected on the spot.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 2 July 2018
Resolved 2 July 2018
Resolution: Corrected on the spot
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 2 July 2018
Resolved
Forward high water alarm inoperable. High water alarm lights do not correspond to associated spaces. Repair/Replace to the satification of the attending MI.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 July 2018
Resolved 18 July 2018
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 2 July 2018
Resolved
Dead end wires in berthing area and head space. Remove or place in appropriate junction box.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 July 2018
Resolved 18 July 2018
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 2 July 2018
Resolved
No charts for operating area. Provide up to date charts.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 July 2018
Resolved 18 July 2018
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 2 July 2018
Resolved
Vessel's log books were missing and when found were not made up to date. Provide books with new entries for maintenance and training/drills.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 July 2018
Resolved 18 July 2018
Lifesaving › Lifefloat › Markings
Issued 5 July 2017
Resolved
Make repairs to life float, clean, install SOLAS retro-tape, label max passengers IAW 185.604.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 August 2017
Resolved 29 September 2017
Resolution: Liferaft was repaired
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 5 July 2017
Resolved
Obtain alcohol test strips IAW 46 CFR16.240
Condition: Invalid
Action required: 705 - Other - as specified
Due 5 August 2017
Resolved 28 September 2017
Resolution: Alcohol strips were provided.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 5 July 2017
Resolved
FCC safety certificate is expired, renew IAW 46 CFR 184.420
Condition: Invalid
Action required: 705 - Other - as specified
Due 5 August 2017
Resolved 28 September 2017
Resolution: Vessel operator was able to get FCC safety cert.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 5 July 2017
Resolved
Obtain smoke detector alarms and install IAW 46 CFR 181.400
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 August 2017
Resolved 28 September 2017
Resolution: Smoke detector was placed and working in accomidation space.
Communications › Alarms/Indicators › Bilge Alarm
Issued 5 July 2017
Resolved
Label high water and bilge lights on console IAW 46 CFR 182.530
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 5 August 2017
Resolved 28 September 2017
Resolution: Items were all labeled on the console.
Communications › Radio Communications › VHF Radiotelephone
Issued 5 July 2017
Resolved
Make DSC GPS operable IAW 47 CFR 80 & 46 CFR 184.520
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 August 2017
Resolved 28 September 2017
Resolution: DSC to GPS on the VHF radio was installed and working.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 5 July 2017
Resolved
Conduct emergency drills and log IAW 46 CFR 185.520
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 August 2017
Resolved 28 September 2017
Resolution: Drills being conducted quarterly.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 5 July 2017
Resolved
Obtain current navigation pubs and charts IAW 184.420
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 August 2017
Resolved 28 September 2017
Resolution: Charts and pubs were provided electronically with additional backup.
Engineering › Fuel Oil Service System › Filter
Issued 5 July 2017
Resolved
Replace raycor filter drain with plug type IAW 46 CFR 182.455
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 August 2017
Resolved 28 September 2017
Resolution: Plug was installed on bottom of raycor fuel filter bowl.
Construction/Loadline › Hull › Bracket
Issued 5 July 2017
Resolved
Clean around tanks, shown during exam, secure bonding wires IAW 46 CFR 176.800
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 August 2017
Resolved 28 September 2017
Resolution: Area was cleaned and wire was bonded.
Communications › Radio Communications › Satellite Communications Capability
Issued 5 July 2017
Resolved
Post exception letter for SAT phone IAW 47 CFR 80.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 August 2017
Resolved 28 September 2017
Resolution: Vessel was able to obtain FCC safety certificate, alleviating the need for sat phone.
Communications › Radio Communications › EPIRB
Issued 6 July 2016
Resolved
EPIRB Hydrostatic release must be renewed. Vessel cannot operate beyond 3 miles.
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 July 2016
Resolved 26 July 2016
Resolution: Replaced hydrostatic release
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 6 July 2016
Resolved
Alcohol testing strips not present. Vessel must remain with 2 hours of shore.
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 July 2016
Resolved 26 July 2016
Resolution: Approved testing devices provided.
Communications › Alarms/Indicators › Bilge Alarm
Issued 6 July 2016
Resolved
All high water visual alarms inoperative; lazarette and engine room float switches inop. Crewmembers must conduct and log visual inspections every 20 min. when underway.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 July 2016
Resolved 26 July 2016
Resolution: Indicator operating correctly
Fire Fighting › Remote Fuel Shutoff › General
Issued 6 July 2016
Resolved
Starboard emergency fuel shut-off handle must be replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 July 2016
Resolved 26 July 2016
Resolution: Handle replaced.
Engineering › Bilge Water Management System › Pump
Issued 6 July 2016
Resolved
Vessel does not have portable hand bilge pump. Provide portable hand bilge pump.
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 July 2016
Resolved 26 July 2016
Resolution: Hand pump provided.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 6 July 2016
Resolved
Required EAP Supervisor training not completed. Provide certificate of completion.
Condition: Invalid
Action required: 705 - Other - as specified
Due 10 August 2016
Resolved 31 August 2016
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 6 July 2016
Resolved
Post EAP hotline number for crewmembers and provide EAP policy for vessel.
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 July 2016
Resolved 26 July 2016
Resolution: EAP hotline posted
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 6 July 2016
Resolved
Crewmembers not listed on DAPI letter. Provide documentation of policy enrollment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 August 2016
Resolved 30 August 2016
Documentation › Safety/Response Plans/Programs › Waste Management Plan
Issued 6 July 2016
Resolved
Waste management plan not posted. Ensure waste management plan is posted.
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 July 2016
Resolved 26 July 2016
Resolution: Waste management plan posted
Navigation › Piloting/Steering › US Coast Pilot
Issued 6 July 2016
Resolved
Vessel could not provide current Coast Pilot. Provide current Coast Pilot for area.
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 July 2016
Resolved 26 July 2016
Resolution: Current Coast Pilot provided
Documentation › Certificates/Documents › Certificate of Inspection
Issued 6 July 2016
Resolved
COI not posted in a visible space for observation by passengers.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 July 2016
Resolved 26 July 2016
Resolution: COI posted
Lifesaving › Liferaft Equipment › First-aid Kit
Issued 6 July 2016
Resolved
First aid kid items expired. Provide current items in first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 July 2016
Resolved 26 July 2016
Resolution: Expired items replaced.
Lifesaving › Emergency Outfit › Flashlight
Issued 6 July 2016
Resolved
Portable light (flashlight) must be located at the access to the engine room.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 July 2016
Resolved 26 July 2016
Resolution: Flashlight provided outside of engine space access.
Documentation › Certificates/Documents › Permit, Other
Issued 6 July 2016
Resolved
All masters aboard vessel must provide current FCC Marine Radio Operator permit.
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 July 2016
Resolved 26 July 2016
Resolution: Provided valid permit
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 6 July 2016
Resolved
MSD holding tank valve must be locked at all times within 3 miles of shore.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 July 2016
Resolved 26 July 2016
Resolution: MSD locked in closed position
Fire Fighting › Means of Escape › Emergency Lighting
Issued 6 July 2016
Resolved
Vessel's emergency lighting must automatically actuate upon failure of main lighting system. Vessel may not embark on overnight trips until corrected.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 July 2016
Resolved 26 July 2016
Resolution: Emergency lighting operated correctly
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 1 April 2009
Resolved
Prove vessel has a drug testing program per 46 CFR 16.
Action required: 705 - Other - as specified
Due 1 May 2009
Resolved 29 April 2009
Resolution: Vessel has provided proof of drug testing program enrollment.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 1 April 2009
Resolved
Replace expired batteries on lifefloat waterlights per 46 CFR 185.726.
Action required: 705 - Other - as specified
Due 1 May 2009
Resolved 29 April 2009
Resolution: There are new batteries in the lifefloat waterlights.
Engineering › Bilge Water Management System › Not Operational
Issued 1 April 2009
Resolved
Prove proper operation of high water level alarm in lazarette per 46 CFR 182.530.
Action required: 705 - Other - as specified
Due 1 May 2009
Resolved 29 April 2009
Resolution: High water level alarm in lazarette operates properly.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 1 April 2009
Resolved
Prove proper operation of navigation lights per 46 CFR 183.420. Vessel shall operate during daylight hours only until cleared.
Action required: 705 - Other - as specified
Due 1 May 2009
Resolved 29 April 2009
Resolution: All navigation lights operate properly.
Communications › Radio Communications › EPIRB
Issued 1 April 2009
Resolved
Replace expired hydrostatic release on EPIRB per 46 CFR 185.740.
Action required: 705 - Other - as specified
Due 1 May 2009
Resolved 29 April 2009
Resolution: There is a new hydrostatic release installed for the EPIRB.
Lifesaving › Lifefloat › Serviceable
Issued 1 April 2009
Resolved
Repair wasted area of stbd lifefloat per 46 CFR 180.175. Vessel shall operate with no more than 15 persons on board until cleared.
Action required: 705 - Other - as specified
Due 1 May 2009
Resolved 29 April 2009
Resolution: The stbd lifefloat has been properly repaired.
Operations/Management › Vessel Safety Management › Emergency Preparedness
Issued 1 April 2009
Resolved
Display specific vessel information including name on emergency broadcast placard per 46 CFR 184.506.
Action required: 705 - Other - as specified
Due 1 May 2009
Resolved 29 April 2009
Resolution: Emergency broadcast placard has been updated with vessel specific information.
Documentation › Markings/Placards › Lifejacket Placard
Issued 1 April 2009
Resolved
Provide donning instruction placards for all types of PFD's on board per 46 CFR 185.516.
Action required: 705 - Other - as specified
Due 1 May 2009
Resolved 29 April 2009
Resolution: Donning placards for all types of PFD''s are displayed.
Communications › Audible Communications › Bell
Issued 1 April 2009
Resolved
Provide and install bell per navigation rule 33.
Action required: 705 - Other - as specified
Due 1 May 2009
Resolved 29 April 2009
Resolution: Vessel has a bell.
Engineering › Generator (propulsion-electric) › Battery
Issued 1 April 2009
Resolved
Replace broken wing nuts on battery terminals and tighten leads per 46 CFR 183.350.
Action required: 705 - Other - as specified
Due 1 May 2009
Resolved 29 April 2009
Resolution: Wing nuts have been replaced and the leads are tight on the battery terminals.
Pollution Prevention/Response › Prevention Equipment › Portable Containment
Issued 18 March 2008
Resolved
Provide a container for the relief hose for the breather for crankcase on both main engines as per 46 CFR 176.800
Due 18 April 2008
Resolved 21 April 2008
Resolution: Containers provided.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 18 March 2008
Resolved
Prove proper operation of the starboard fuel shutoff valve as per 46 CFR 182.455
Due 18 April 2008
Resolved 21 April 2008
Resolution: Shutoff valve tested sat.
Electrical › Electric Generation Source (service) › Overcurrent Device
Issued 18 March 2008
Resolved
Prove generator is deratted to 80% as per 46 CFR 182.455
Due 18 April 2008
Resolved 21 April 2008
Resolution: Generator has a 50 amp breaker and should be deratted to no more than 64 amps (80% of 83 amps - full load capcity).
Lifesaving › Lifefloat › Paddle
Issued 18 March 2008
Resolved
Properly attach the paddles to the lifefloats as per 46 CFR 180.175
Due 18 April 2008
Resolved 21 April 2008
Resolution: Paddles attached.
Lifesaving › Lifefloat › Markings
Issued 18 March 2008
Resolved
Properly label the vessel name on the lifefloat paddles and life ring as per 46 CFR 185.604
Due 18 April 2008
Resolved 21 April 2008
Resolution: Properly labeled.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 18 March 2008
Resolved
Properly label the storage for the lifefjackets with the correct number being stowed as per 46 CFR 180.78
Due 18 April 2008
Resolved 21 April 2008
Resolution: Added lifejackets to meet storage labels.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 31 May 2007
Resolved
Provide a fire detecting system for overnight accommodation space as required by 46 CFR 181.400
Action required: 705 - Other - as specified
Due 1 July 2007
Resolved 11 June 2007
Resolution: Provided a fire detecting system for overnight accomodation space.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 31 May 2007
Resolved
Mark lifejacket stowage areas with total number of lifejackets in each area as required by 46 CFR 185.604
Action required: 705 - Other - as specified
Due 1 July 2007
Resolved 11 June 2007
Resolution: Marked lifejacket stowage ares with the total number of lifejackets in each area.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 31 May 2007
Resolved
Provide lights for each lifejacket as required by 46 CFR 180.75
Action required: 705 - Other - as specified
Due 1 July 2007
Resolved 11 June 2007
Resolution: Provided lights for each lifejacket.
Electrical › Electric Generation Source (service) › Panelboard
Issued 31 May 2007
Resolved
Provide a nameplate that states "This generator has been derated to 80% of maximum output as per 46CFR183.320" to be posted on the generator
Action required: 705 - Other - as specified
Due 1 July 2007
Resolved 11 June 2007
Resolution: Provided nameplate stating the generator has been derated to 80% of maximum output.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 31 May 2007
Resolved
Mark emergency exits in clearly legible letters "EMERGENCY EXIT, KEEP CLEAR" as required by 46CFR185.606
Action required: 705 - Other - as specified
Due 1 July 2007
Resolved 11 June 2007
Resolution: Marked emergency exits in clearly legible letters "EMERGENCY EXIT, KEEP CLEAR".