Records from 2006 to 2022. Most recent: inspection, 17 October 2022.
Documentation record
Registered dimensions (L × B × D)46.5 ft × 15.0 ft × 6.5 ft
Registered tonnagegross 30 / net 24
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNEUVILLE BOAT WORKS INC · NEW IBERIA, LA, UNITED STATES · built 2007
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portCHAUVIN, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 24 June 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it30 - Simplified, Gross Ton
24 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 14
17 October 2022
Administrative Inspection
Administrative · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7579087
9 November 2020
Administrative Inspection
Administrative · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7092202
22 July 2020
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7019491
21 October 2019
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6839956
27 June 2018
Administrative Inspection · COI Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6457778
28 September 2017
Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6277088
14 June 2016
Hull Examination · Annual Inspection · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5907654
29 September 2015
Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5731784
11 June 2014
Internal Structural Exam · Annual Inspection · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4886027
14 June 2012
Drydock Exam · Examination of Repairs · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4343649
11 August 2011
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4112445
1 July 2008
Administrative Inspection · Hull Examination · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3248361
6 April 2007
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2904162
19 October 2006
Initial Construction-Excluding Oversight · Initial Certification · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2803774
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 17 October 2022
Resolved
A vessel to which this subchapter applies may not be operated without having on board a valid U.S. Coast Guard Certificate of Inspection (COI). On May 18, 2021, the [name withheld] was boarded by Sector New Orleans boarding team and identified the vessel to have 1 crewmember and 8 passengers aboard. On October 19, 2020, your office surrendered the vessels COI and requested to place the vessel in laid up status, subsequently approved by our office on November 10, 2022. It has been determined that your vessel was operating with passengers aboard without a valid COI. The [name withheld] shall not operate with cargo or passengers onboard until a valid COI is attained.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 June 2023
Resolution: Vessel to remain laid up and not operate commercially until a COI inspection is completed.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 21 October 2019
No resolution recorded
As appropriate for the intended voyage vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible. Vessel had charts dated for 30 Sept which required updates. 46 CFR 184.420
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 October 2019
No resolution recorded
he installation and location of portable fire extinguishers must be to the satisfaction of the Officer in Charge, Marine Inspection. Pilothouse portable fire extinguisher bracket was of the wall hook type allowing extinguisher to swing loosely. Provide an approved latch type bracket for existing extinguisher or renew extinguisher with a provided latch bracket. Space is required (1) 10-B:C. 46 CFR 181.520
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 21 October 2019
No resolution recorded
Life float water lights must be a floating water light approved under approval series 161.010 or other standard specified by the Commandant. Installed life float water light batteries were not of the approved type as noted on water light container which allowed light to float too low in the water. 46 CFR 180.175(f)(4)
Action required: 17 - Rectify deficiencies prior to departure
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 21 October 2019
No resolution recorded
The master shall operate the vessel keeping the safety of the passengers and crew foremost in mind by directing the vessel in order to prevent a casualty. Special attention should be paid to magnetic variation and deviation errors of the compass. Master could not locate compass deviation table. 46 CFR § 185.304(a)(8)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 10 August 2018
Resolved
Machinery Space bilge alarm is not working and needs to be fixed within 14 days.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 August 2018
Resolved 14 August 2018
Resolution: Bilge alarm was replaced with a new one. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 10 August 2018
Resolved
Lifejacket stowage locations need to be marked to accurately reflect the proper number of lifejackets stowed within. To be corrected within 14 days.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 August 2018
Resolved 14 August 2018
Resolution: Stowage markings were updated to accurately reflect the proper number of lifejackets contained within.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 August 2018
Resolved
A fixed CO2 system function test needs to be conducted in the presence of a CG Marine Inspector prior to the vessel operating.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 31 August 2018
Resolved 14 August 2018
Resolution: Witnessed successful completion of fixed CO2 system function test. All sat.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 11 August 2011
Resolved
Rudder room bilge alarm wiring junction box was being held with a tie wrap. Required box to be permanently secured using fasteners.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 August 2011
Resolution: Corrected.
Engineering › Bilge Water Management System › Piping
Issued 11 August 2011
Resolved
Electrical submersible bilge pump discharge hose did not have a check valve to prevent backflow from installed bilge system.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 August 2011
Resolution: Check valve was installed.
Lifesaving › Lifefloat › Markings
Issued 11 August 2011
Resolved
all of vsls waterlights markings were unreadable.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 August 2011
Resolution: Stenciled.