STEILACOOM II

STEILACOOM II is a 2006 passenger vessel (inspected). The Coast Guard has recorded 63 inspections since 2007, most recently in March 2026, along with 33 deficiencies, 1 operational control and 12 casualty investigations between 2007 and 2026.

Records from 2007 to 2026. Most recent: inspection, 14 March 2026.

Built
2006
Last inspected
14 March 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDD5115
861363
Flag
UNITED STATES
367153930
Maury page id
psix-861363

Inspections, by type

…with no type recorded13
Years with a record 16 calendar years (2007–2026)
The 63 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)198.6 ft × 68.0 ft × 16.0 ft
Registered tonnagegross 97 / net 66
ITC dimensions (L × B × D)198.6 ft × 68.0 ft × 16.0 ft
ITC tonnagegross 1,732 / net 484
BuilderNICHOLS BROS BOAT BUILDERS INC · FREELAND, WA, UNITED STATES · built 2006
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSTEILACOOM, WA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 12 June 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1732 - Convention (Subpart B), Gross Ton
97 - Regulatory (Subpart C or D), Gross Ton
484 - Convention (Subpart B), Net Ton
66 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDJ4656MMSI 367153930 · active · compulsorily equipped · granted 30 March 2017, expires 30 March 2027
WDD5115MMSI 367153930 · cancelled · voluntarily equipped · granted 5 December 2006, cancelled 5 December 2016
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 63

14 March 2026 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8351038
5 December 2025 Vessel Attendance · Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8278370
3 October 2025 Deficiency Check · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8236519
4 September 2025 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8218789
9 May 2025 Internal Structural Exam · Underwater Inspection in lieu of Drydock
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8136750
7 March 2025 Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8261433
18 January 2025 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8065181
5 December 2024 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8043969
25 October 2024 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8021317
13 June 2024 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7934444
18 October 2023 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7810889
29 March 2023 Plan Review (Other than "T") · Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7664747
25 February 2023 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7641794
24 February 2023 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7656604
17 January 2023 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7622832
3 November 2021 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7344771
12 October 2021 Annual Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7327666
18 May 2021 Internal Structural Exam · Underwater Inspection in lieu of Drydock
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7199502
1 February 2021 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7134377
26 October 2020 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7075825
25 May 2020 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6960313
18 October 2019 DAPI Audit · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6835140
7 February 2019 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6622008
28 December 2018 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6603658
30 October 2018 DAPI Audit · MTSA Verification · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6569166
18 September 2018 Administrative Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6543596
13 September 2018 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6540103
13 August 2018 Deficiency Check · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6510737
12 May 2018 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6414488
20 April 2018 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6395292
23 February 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6360531
13 October 2017 Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6264672
3 October 2017 Damage Survey · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6294815
3 May 2017 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6150129
10 January 2017 Underwater Inspection in lieu of Drydock · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6068590
30 November 2016 Annual Inspection · MTSA/ISPS Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6050979
18 April 2016 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5857103
29 February 2016 Examination of Repairs
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5823925
29 February 2016 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5824078
23 February 2016 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5820239
1 May 2012 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4299152
14 December 2011 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4208453
8 December 2011 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4204521
14 September 2011 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4152851
16 February 2011 COI Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3912683
19 January 2011 Drydock Extension · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3933894
20 February 2010 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3697429
17 February 2010 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3692733
9 January 2010 Deficiency Check · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3660268
19 December 2009 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3654649
6 March 2009 Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3430547
6 March 2009 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3431609
9 February 2009 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3413641
20 January 2009 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3395620
17 November 2008 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3377531
7 November 2008 Drydock Extension
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3359015
15 September 2008 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3327650
14 August 2008 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3303060
25 March 2008 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3171251
17 March 2008 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3166199
5 February 2008 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3142289
21 January 2008 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3131641
30 December 2007 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3229066

Deficiency record · 33

07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 3 October 2025 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspection of electrical equipment and systems, including the following: (h)Operational test of all emergency electrical systems. During test of emergency lighting observed the following issues with e-lights as marked/shown on FCP: -inoperable emergency lighting (3) in engine room -missing retro-reflective lighting strip on bottom step leading out of engine room -inoperable emergency light (1) near elevator, car deck. -inoperable lighted "EXIT" signs in main pax cabin.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2025
Resolved 4 November 2025
Resolution: Recieved pictures attesting to all emergency lighting operable.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 3 October 2025 Resolved
At each initial and subsequent inspection for certification, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment, including the following: (7)Inspection and testing of smoke and fire detecting systems (including sensors and alarms) and fire confining appliances (such as fire screen doors and fire dampers).As prescribed on the approved fire control plan, the double leaf doors leading to the main passenger cabin on both #1 and #2 end are required to be self-closing doors. On each end, one of the two door leafs did not fully close when tested.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2025
Resolved 17 November 2025
Resolution: received video attesting to proper closure of doors
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 3 October 2025 Resolved
Each door, hatch, or scuttle, used as a means of escape, must be capable of being opened by one person, from either side, in both light and dark conditions. The method of opening a means of escape must be obvious, rapid, and of adequate strength. Both doors leading to the main passenger cabin on #1 and #2 end have deadbolt locks on the upper part of the door. If locked from the inside, passengers pushing on the normal crash bar door opening device would not be able to open the door and egress from the main passenger cabin.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2025
Resolved 8 December 2025
Resolution: While attending vessel for DD/ISE, attending MI confirmed that locks had been changed out to the double-sided key style, all satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 25 October 2024 Resolved
Each ring life buoy must be marked with Type II retroreflective material approved in accordance with § 164.018 in subchapter Q of this chapter, or other standard specified by the Commandant. MI observed 01 ring life buoy on the #1 end upper deck Type II SOLAS tape to be deteriorated by UV light and requires replacement.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 November 2024
Resolved 31 October 2024
Resolution: Recieved photgraph providing sufficent evidence of deficency being corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 25 October 2024 Resolved
Each battery used in an item of lifesaving equipment, except inflatable survival craft equipment, must be replaced during the annual inspection if the expiration date of the battery has passed. The expiration date of the battery may be marked on the battery in clearly legible letters or the owner or managing operator may have a record of the expiration date from the manufacturer of a battery marked with a serial number. MI observed floating waterlight on the #2 end of upper deck ring life buoy to have an expired battery which requires replacement.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 November 2024
Resolved 31 October 2024
Resolution: Recieved photgraph providing sufficent evidence of deficency being corrected.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 20 June 2023 Resolved
Before construction or conversion of a vessel intended for small passenger service, the owner of the vessel shall submit plans, manuals, and calculations indicating the proposed arrangement, construction, and operations of the vessel, to the Marine Safety Center for approval. The plans, manuals and calculations required to be submitted and the disposition of these plans are set forth in Part 116, Subpart B of this subchapter. Vessel modified steering control system during drydock. Approval from MSC is pending.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 July 2023
Resolved 7 July 2023
Resolution: Received MSC plan approval for steering. Serial: E2-2302283
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 25 February 2023 Resolved
Low power alarm indicated on the number 1 generator. Troubleshooting uncovered 2 faulty injectors on the fuel system not allowing the generator to make full power.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 March 2023
Resolved 8 March 2023
Resolution: USCG witnessed 30 minute load test on #1 generator. ALLSAT
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 May 2021 Resolved
During the Internal Structure Exam, as required by 46 CFR 115.600, inspectors noted an inset that exceeds the allowable standards. The inset is located in the #1 End, void #3 on the stbd fwd end, between fr 16 & 17. The inset was supposed to be corrected at the last DDX but was overlooked due to the yard filing for bankruptcy. Needs to be corrected at next DDX.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 May 2023
Resolved 24 May 2023
Resolution: Inset cropped and renewed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 October 2020 Resolved
#1 air receiver relief valve did not properly open at its set point. Demonstrate test of relief valve to USCG inspector. Cross connect valve is to remain open.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 November 2020
Resolved 12 November 2020
Resolution: Vessel operator replaced relief valve for #1 air receiver. Vessel operator sent pictures and certificate from manufacturer showing tests performed on valve replacement.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 October 2020 Resolved
Stow child sized lifejackets IAW Fire Control Plan.
Action required: 10 - Deficiency Rectified
Due 26 October 2020
Resolved 27 October 2020
Resolution: Vessel put childrens lifejackets in bag to separate from adult lifejackets within compartment.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 October 2019 Resolved
The remote operated valve for the collision bulkhead bilge suction in the steering compartment did not operate/valve is seized. 46CFR119.500(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 November 2019
Resolved 1 November 2019
Resolution: Attended vesel and verified proper operation of ROVs.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 October 2019 Resolved
The positive end of the power cable connected to the #2 Main engine ECM has exposed terminals. 46CFR120.200(b)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 November 2019
Resolved 22 October 2019
Resolution: Operator installed proper electrical cover and provided photo for proof.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 October 2019 Resolved
The power supply under the #2 end console is laying loose and needs to be properly secured. 46CFR120.220(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 November 2019
Resolved 22 October 2019
Resolution: Operator properly installed and secured power supply, provided photo for proof.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 August 2018 Resolved
13199 - Propulsion must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its design limitations. CPP system cooling failure on one of two shafts. - 46 CFR 119.200
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 August 2018
Electrical › Electric Supply System (service) › Battery Installation
Issued 20 April 2018 Resolved
One of the vital batteries was overheating and found to be bad.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2018
Resolved 24 April 2018
Resolution: Vessel representative provided documentaion that batteries were replaced and deficiency has been corrected.
Documentation › Certificates/Documents › Permit, Other
Issued 18 April 2016 Resolved
It was discovered that the Vessel was allowing passengers to take propane tanks onboard without a proper permit. Vessels representative has been notified and a proper permit must be acquired by 20MAY16. In the interim Vessel is required to follow the guidelines stated in the Washington State Ferry permit and procedure for portable Propane Cylinders.
Due 20 May 2016
Resolved 3 May 2016
Resolution: Due to approved but unpublished changes to the CFR DOT is no longer issuing theese permits. The contents of the permits were incorporated to 49CFR176.90 and will be published 27JAN17.
Engineering › Steering Gear System › Pump
Issued 29 February 2016 Resolved
Vessel experienced steering failure on both ends. Repair steering systems to the satisfaction of the attending Marine Inspector.
Action required: 705 - Other - as specified
Due 7 March 2016
Resolved 15 March 2016
Resolution: Pump motor, circuit board and fuse replaced. Sea Trials All Sat.
Communications › Alarms/Indicators › General Alarm
Issued 23 February 2016 Resolved
Prove proper operation of the general alarm in accordance with 46CFR113.25
Action required: 705 - Other - as specified
Due 1 March 2016
Resolved 23 February 2016
Electrical › Electric Generation Source (service) › Generator
Issued 19 January 2011 Resolved
Replace J/W High temp shut-down switch on No. 2 Ship Service Generator.
Action required: 705 - Other - as specified
Due 27 January 2011
Resolved 27 January 2011
Resolution: Replaced.
Lifesaving › Hand Flares › Expired
Issued 9 January 2010 Resolved
All six required hand flares were expired. Prove required distress signals are onboard prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 January 2010
Resolved 9 January 2010
Resolution: Proper distress signals were installed.
Engineering › Steering Gear System › Solenoid Valve
Issued 6 March 2009 Resolved
Demonstrate proper operation of #1 end steering system.
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 March 2009
Resolved 7 March 2009
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 9 February 2009 Resolved
Prove proper operation of direction 1 port and starboard running lights (upper) to the on scene marine inspector in accordance with 46CFR120.420.
Action required: 705 - Other - as specified
Due 17 February 2009
Resolved 12 February 2009
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 6 February 2009 Resolved
Prove proper operation of CO2 discharge alarms in the engine room in accordance with 46CFR118.400.
Due 9 February 2009
Resolved 9 February 2009
Resolution: Vessel rep had pipes to alarms cleaned and retested alarms. Alarms appeared satisfactory.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 6 February 2009 Resolved
Life ring markings were faded and not adequately visible. Provide proper life ring markings in accordance with 46CFR122.604.
Due 9 February 2009
Resolved 9 February 2009
Resolution: Vessel re-applied life ring markings to satisfaction of on scene marine inspector.
Lifesaving › Launching Appliances › Davit
Issued 6 February 2009 Resolved
Provide placard on rescue boat davit with operating warning regarding circuit breaker and instructions on how to reset breaker to the satisfaction on scene marine inspector NLT 17FEB09 in accordance with 46CFR117.210.
Action required: 705 - Other - as specified
Due 17 February 2009
Resolved 12 February 2009
Resolution: Received picture of satisfactory placard posted on davit.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 6 February 2008 Resolved
Replace Lifering light above Firestation #7. Currently not operating.
Condition: Unknown
Due 16 February 2008
Resolved 8 February 2008
Resolution: Replaced lifering light as required.
Operations/Management › Passenger Operations › Safety Orientation
Issued 6 February 2008 Resolved
Install safety stripes near all three rescue doors on car deck to prevent vehicles from parking in front of doors.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 February 2008
Resolution: Painted walkways on car deck to appropriately show areas for vehicles not to park directly in front of the rescue doors.
Fire Fighting › Fire Hoses › Number
Issued 6 February 2008 Resolved
Add one additional fire hose to each firestation on car deck.
Due 16 February 2008
Resolved 8 February 2008
Resolution: Added one 50'' fire hose to each of the two firestations located on the car deck.
Construction/Loadline › Structures › Superstructure
Issued 6 February 2008 Resolved
Place safety line connecting hand rails on outboard side of rescue boat while in stowed position.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 February 2008
Resolution: Safety line installed outboard of rescue boat.
Communications › Visual Communication › Signalling Lamp
Issued 6 February 2008 Resolved
Install lights in engine room for general emergency; 1 on #1 end, 1 on #2 end, and 1 in control room.
Action required: 705 - Other - as specified
Due 7 March 2008
Resolved 14 March 2008
Resolution: Watch stander stands watch in booth, general emergency alarm can be heard from booth, removed CG-835.
Communications › Alarms/Indicators › General Alarm
Issued 6 February 2008 Resolved
Fix 02 lights for general alarm located on car deck.
Action required: 705 - Other - as specified
Due 7 March 2008
Resolved 14 March 2008
Resolution: 02 lights for general alarm repaired on car deck.
Communications › Audible Communications › Bell
Issued 6 February 2008 Resolved
Install bell for fire alarm in engine room on STBD. side.
Action required: 705 - Other - as specified
Due 7 March 2008
Resolved 14 March 2008
Resolution: Watch stander maintains the watch in the booth, the bell/indication can be heard from the booth, cleared CG-835.
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 6 February 2008 Resolved
Make repairs to flow return line for #1 end fuel tank. Monitor current leak (approx. 4 drops/min) & contact CG marine inspector is leak increases.
Action required: 705 - Other - as specified
Due 7 March 2008
Resolved 14 March 2008
Resolution: A shut off was placed on f/o tanks #1&2 end, leak is repaired.

Casualty record · 12

30 December 2007Routine · role: Involved in a Marine Casualty · activity 3229066
14 August 2008Routine · role: Involved in a Marine Casualty · activity 3303060
17 November 2008Routine · role: Involved in a Marine Casualty · activity 3377531
6 March 2009Routine · role: Involved in a Marine Casualty · activity 3431609
3 August 2009Routine · role: Involved in a Marine Casualty · activity 3562266
28 October 2009Routine · role: Involved in a Marine Casualty · activity 3624896
19 December 2009Routine · role: Involved in a Marine Casualty · activity 3654649
29 February 2016Routine · role: Involved in a Marine Casualty · activity 5824078
12 May 2018Routine · role: Involved in a Marine Casualty · activity 6414488
1 February 2021Routine · role: Involved in a Marine Casualty · activity 7134377
24 February 2023Routine · role: Involved in a Marine Casualty · activity 7656604
14 March 2026Routine · role: Involved in a Marine Casualty · activity 8351038
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.