← All vessels
MTM WESTPORT
MTM WESTPORT is a 2005 tank ship. The Coast Guard has recorded 27 inspections since 2006, most recently in February 2026, along with 8 deficiencies and 4 operational controls.
Records from 2006 to 2026. Most recent: inspection, 25 February 2026.
- Built
- 2005
- Last inspected
- 25 February 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 8 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9317858 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9V6816
862191
Flag
SINGAPORE
—
Maury page id
psix-862191
Inspections, by type
…with no type recorded7
Years with a record
13 calendar years (2006–2026)
The 27 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it18760 - Convention (Subpart B), Gross Ton
39776 - Displacement, Metric Ton
32044 - Dead Weight, Metric Ton
9393 - Convention (Subpart B), Net Ton
39776 - Displacement, Metric Ton
32044 - Dead Weight, Metric Ton
9393 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 27
25 February 2026
COC-CHEM & TVE Renew · PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8311128
5 August 2024
PSC B · COC-CHEM & TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7967660
7 April 2023
COC-CHEM & TVE Renew · PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7660801
14 September 2021
Deficiency Check · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7312035
28 July 2021
PSC B · COC-CHEM & TVE Renew
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7265455
23 July 2021
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7265457
10 February 2020
Deficiency Check · ISM Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6907119
9 February 2020
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6905657
24 May 2019
COC-CHEM & TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6686316
21 November 2017
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6314022
8 November 2017
ISPS II Exam · Deficiency Check · Ballast Water Examination · COC-CHEM & TVE Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6299592
15 August 2017
COE-Dockside
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6241335
23 February 2017
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6093735
10 October 2016
Ballast Water Examination · ISPS II Exam · COC-CHEM & TVE Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6017829
3 January 2012
ISPS II Exam · COC-CHEM Annual · Ballast Water Examination
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 4213793
24 December 2010
Ballast Water Examination · COC-CHEM Renew · ISPS III Exam
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3913924
12 February 2010
ISPS II Exam · COC-CHEM Annual · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3679346
30 December 2008
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3386497
6 December 2008
ISPS II Exam · Deficiency Check · COC-CHEM Renew · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3374548
1 May 2008
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3196822
1 May 2008
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3197073
13 February 2008
MARPOL Annex II Examination
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3147071
5 January 2008
ISPS II Exam · Ballast Water Examination · COC-CHEM Renew · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3119548
9 January 2007
Random ISPS/MTSA/PSC
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2853132
8 January 2007
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2852265
7 January 2007
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2850285
30 October 2006
MARPOL Annex I Examination · ISPS II Exam · Ballast Water Examination · MARPOL Annex V Examination · MARPOL Annex II Examination · COC-CHEM Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2810476
Deficiency record · 8
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 28 July 2021
Resolved
All gasketed cargo-pipe joints and hose connections shall be electrically bonded. PSCO discovered numerous bonding wires throughout the cargo deck area worn and not connected.
74 SOLAS(20)VII/10.1
IBC Code 10.2
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 10 February 2020
Resolved
The owner, master, or person in charge of each vessel underway shall ensure that the vessel's anchors are ready for letting go. PSCO conducted in-service exam after pilot reported port anchor shain was fouled. PSCO observed port anchor successfully let go and no fouling of anchor chain.
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 8 November 2017
Resolved
1199- THE INERT GAS SYSTEM SHALL BE CAPABLE OF INERTING, PURGING AND GAS-FREEING EMPTY TANKS AND MAINTAINING THE ATMOSPHERE IN CARGO TANKS WITH THE REQUIRED OXYGEN CONTENT. THE IGG COMBUSTION AIR BLOWER IS INOPERABLE, INHIBITING THE INERTING CAPABILITIES OF THE INERT GAS SYSTEM. 74 SOLAS (14 CONS) II-2/4.5.5.3.1, 40AC.
Construction/Loadline › Markings › Load Line Mark
Issued 6 December 2008
Resolved
1220: Load line is not of a contrasting color to the hull as per ICLL requirement. Load line was surveyed November 2, 2008. Appearance of the load lines on Port and Starboard side indicate that it has not been of a contrasting color since March dry-dock.
Documentation › Logs/Records › Ballast Water Logs/Records
Issued 6 December 2008
Resolved
0199: Ballast water Management Plan requires training for all crew members with responsibilities regarding ballast operations and that training be recorded and validated: raining log is not current nor validated. Plan also requires a Record of Sediment be kept with the handling log and no records have been kept.
Lifesaving › Immersion Suits › General
Issued 6 December 2008
Resolved
0663: During Abandon Ship Drill, observed several immersion suits too large for crew members. Additionally, lifesaving equipment certificate form E does not indicate that suits meet requirements of needing a life jacket; immersion suits have buoyant collar, a light, and a whistle.
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 6 December 2008
Resolved
0320: Air Conditioning room's intake ducting leading to main accommodation space supply ventilator is holed and wasted. In the event of a fire, oxygen cannot be secured to the area and could allow the fire to spread.
Communications › Alarms/Indicators › Fire Alarm
Issued 30 October 2006
Resolved
WHEN FIRE DETECTOR ON SHIP IS ACTIVATED, THERE IS NO AUDIBLE OR VISUAL ALARM IN ENGINE CONTROL ROOM TO ALERT RESPONSIBLE ENGINEER AS REQUIRED BY SOLAS II-2 7.4.2. INSTALL AUDIBLE AND VISUAL FIRE ALARM SO RESPONSIBLE ENGINEER CAN BE ALERTED OF ANY FIRE DETECTOR ACTIVATION TO THE SATISFACTION OF FLAG STATE BY NOVEMBER 30, 2006.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.