Records from 2008 to 2021. Most recent: inspection, 4 August 2021.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 20
4 August 2021
COE-Administrative
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7277030
4 November 2020
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7089478
30 January 2020
Annual Inspection · Administrative Inspection · MTSA/ISPS Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6899745
2 December 2019
Drydock Exam · Internal Structural Exam · Cargo Tank Internal
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6865403
3 June 2019
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6702456
18 April 2019
Annual Inspection · MARPOL Annex VI Survey · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6655637
11 February 2019
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6624094
28 September 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6550928
22 June 2018
Administrative Inspection · MARPOL Annex VI Survey · COI Inspection · MTSA/ISPS Verification · Construction Oversight · MARPOL Annex IV Survey · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6452494
8 May 2018
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6409382
25 January 2017
Administrative Inspection · Internal Structural Exam · Drydock Exam · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6077094
12 February 2016
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5825076
18 March 2014
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4818840
17 January 2012
Administrative Inspection · COI Inspection · MTSA Verification · Drydock Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4228432
4 January 2011
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3920569
19 January 2010
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3665978
7 January 2010
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3660503
19 March 2009
MTSA Verification · Re-Inspection · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3457264
28 October 2008
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3366005
6 May 2008
Administrative Inspection · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3195732
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 18 April 2019
Resolved
Create rescue boat inspection schedule in SMS and provide inventory list in rescue boat.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 May 2019
Resolved 29 April 2019
Resolution: Received email from vessel rep wit attachments illustrating def has been rectified.
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 18 April 2019
Resolved
Replace both port and straboard jacob's ladders.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 May 2019
Resolved 16 May 2019
Resolution: Received email from vessel rep with pictures and invoice to show that new jacobs ladders were purchased and have been installed onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boat inventory
Issued 18 April 2019
Resolved
Provide full inventory of rescue boat to include replacing the fire extinguisher.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 May 2019
Resolved 29 April 2019
Resolution: Received email from vessel rep wit attachments illustrating def has been rectified.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 18 April 2019
Resolved
Provide proof that overdue bridge maintainence inspections are conducted as per SMS.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 May 2019
Resolved 29 April 2019
Resolution: Received email from vessel rep wit attachments illustrating def has been rectified.
10 - Safety of Navigation › N/A - No Subsystem › Long-range identification and tracking system (LRIT)
Issued 28 September 2018
Resolved
Vessel has failed to report via LRIT per 33 CFR 169.230
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 May 2019
Resolution: Spoke with NAVCEN and they confirmed that the vessel is now reporting through LRIT as they are required.
Engineering › Fuel Oil Service System › Flange
Issued 25 January 2017
Resolved
Port and Starboard Fuel valve flanges showed sign of excessive corrison. Rep removed coating and determine one valve flange needed replacing
Condition: Improper/Lack of Maintenance
Due 7 February 2017
Resolved 8 February 2017
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 25 January 2017
Resolved
Need hand rails installed behind the Pilot since the vsl remove Life floats
Condition: Invalid
Due 7 February 2017
Resolved 8 February 2017
Engineering › Steering Gear System › Ram
Issued 25 January 2017
Resolved
Ram seal was leaking vsl needed to replace it
Condition: Improper/Lack of Maintenance
Due 6 February 2017
Resolved 6 February 2017
Construction/Loadline › Markings › Load Line Mark
Issued 25 January 2017
Resolved
load line was not readable had them re-paint it.
Due 7 February 2017
Resolved 8 February 2017
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 19 March 2009
Resolved
Place sign at stove directing crewmembers to range disconnect
Due 19 April 2009
Resolved 25 March 2009
Documentation › Markings/Placards › Warning Signs
Issued 19 March 2009
Resolved
Label all access to CO2 protected spaces with "CO2 Protected space" signs.
Due 19 April 2009
Resolved 25 March 2009
Fire Fighting › Means of Escape › Emergency Lighting
Issued 19 March 2009
Resolved
Demostrate lighting is in working order.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 March 2009
Fire Fighting › Fire Main › Condition
Issued 19 March 2009
Resolved
Ensure cross-over valve is stencilled to remain open to ensure all fire fighting stations can be operated from one fire pump.
Due 19 April 2009
Resolved 25 March 2009
Fire Fighting › Remote Fuel Shutoff › General
Issued 19 March 2009
Resolved
Label all independent deck shutoffs with engien it secures and move 1 shutdwon valve off of common crossover pipe so engine may be secured with one shutdown.
Due 19 April 2009
Resolved 19 March 2009