Records from 1985 to 1990. Most recent: inspection, 12 October 1990.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 22
12 October 1990
Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1232028
24 August 1990
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 901806
26 May 1990
COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1229649
11 May 1990
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 918549
11 May 1990
Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1223883
7 December 1989
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 914981
22 June 1989
Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 889030
22 June 1989
Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1197437
14 February 1989
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1036827
22 November 1988
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1034806
8 September 1988
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 491186
17 August 1988
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 497153
5 August 1988
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 455147
8 June 1988
COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 892032
9 July 1987
Hull Examination · Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1325477
21 May 1987
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 511773
19 May 1987
Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1023786
3 December 1986
Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1021483
1 December 1986
Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1331441
5 June 1986
COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1299555
17 June 1985
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1291803
26 April 1985
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 436475
Deck/Cargo
Issued 26 May 1990
Resolved
CONDUCT SATISFACTORY HYDRSTATIC TEST OF CARGO TRANSFER HOSE AND LOG SAME PRIOR TO NEXT CARGO TRANSFER.
Condition: Unknown
Due 29 June 1990
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 26 May 1990
Resolved
INSTALL A FLAME IMPINGEMENT BOWL ON THE STARBOARD GENERATOR (50 KW) FUEL FILTER, OR CHANGE THE FUEL FILTER TO AN ALL METALLIC FILTER.
Condition: Unknown
Due 29 June 1990
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 26 May 1990
Resolved
MAKE SUITABLE PERMANENT REPAIRS TO THE UNDERDECK FRAMING LOCATED OVER THE PORT SIDE 100 KW GENERATOR.
Condition: Unknown
Due 29 June 1990
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 26 May 1990
Resolved
OBTAIN APPROVAL AND CONDUCT TESTING OF THE CARGO HANDLING CRANE LOCATED ON THE STARBOARD FORWARD QUARTER IN ACCORDANCE WITH 46 CFR 91.37. THIS ITEM TO BE COMPLETED PRIOR TO USING THE CRANE FOR CARGO OPERATIONS.
Condition: Unknown
Due 29 June 1990
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 26 May 1990
Resolved
PROVIDE STABILITY INFORMATION FOR REVIEW AND APPROVAL FOR THE CRANE IN ACCORDANCE WITH 46 CFR PART 173 SUBPART B. THIS ITEM TO BE COMPLETED PRIORTO USING THE CRANE FOR CARGO OPERATIONS.
Condition: Unknown
Due 26 May 1990
Resolved 26 May 1990
Unknown
Issued 8 June 1988
Resolved
PROVIDE CO2 WARNING SIGN FOR PAINT LOCKER.
Condition: Unknown
Due 8 June 1988
Resolved 8 June 1988
Unknown
Issued 8 June 1988
Resolved
REPACK STARBOARD MAIN ENGINE PROPELLER SHAFT PACKING GLAND.
Condition: Unknown
Due 8 June 1988
Resolved 8 June 1988
Unknown
Issued 8 June 1988
Resolved
PROVIDE COVER FOR STARBOARD GENERATOR PECKERHEAD.
Condition: Unknown
Due 8 June 1988
Resolved 8 June 1988
Unknown
Issued 8 June 1988
Resolved
RESTENCIL ALL FIRE STATIONS.
Condition: Unknown
Due 8 June 1988
Resolved 8 June 1988
Unknown
Issued 8 June 1988
Resolved
HYDRO HEATING BOILER AND TEST OPERATION OF RELIEF VALVE.
Condition: Unknown
Due 8 June 1988
Resolved 8 June 1988
Unknown
Issued 8 June 1988
Resolved
MAKE LAZERETTE SPACES READY FOR INTERNAL INSPECTION.
Condition: Unknown
Due 8 June 1988
Resolved 8 June 1988
Unknown
Issued 8 June 1988
Resolved
REPLACE CLOTHES DRYER WIRING FROM CIRCUIT BREAKER PANEL TO OUTLET.
Condition: Unknown
Due 8 June 1988
Resolved 8 June 1988
Unknown
Issued 8 June 1988
Resolved
PROPERLY SUPPORT BATTERY CABLE FOR STARBOARD MAIN ENGINE.
Condition: Unknown
Due 8 June 1988
Resolved 8 June 1988
Unknown
Issued 8 June 1988
Resolved
HYDRO TWO AIR RECEIVERS AND TEST RELIEF VALVES.
Condition: Unknown
Due 8 June 1988
Resolved 8 June 1988
Unknown
Issued 8 June 1988
Resolved
REPAIR COOLING WATER LEAK ON CENTER MAIN ENGINE AND BOLT DOWN ENGINE ACCESSCOVERS.
Condition: Unknown
Due 8 June 1988
Resolved 8 June 1988
Unknown
Issued 8 June 1988
Resolved
RELAG CENTER MAIN ENGINE EXHAUST.
Condition: Unknown
Due 8 June 1988
Resolved 8 June 1988
Unknown
Issued 8 June 1988
Resolved
REPAIR MAIN ENGINE TACHOMETERS.
Condition: Unknown
Due 8 June 1988
Resolved 8 June 1988
Unknown
Issued 8 June 1988
Resolved
REPAIR OR REMOVE DECK CRANE STARBOARD SIDE FORE CASTLE.
Condition: Unknown
Due 8 June 1988
Resolved 8 June 1988
Unknown
Issued 8 June 1988
Resolved
PROVIDE PERMANENT DRIP PAN FOR FUEL TRANSFER PUMP.
Condition: Unknown
Due 8 June 1988
Resolved 8 June 1988
Unknown
Issued 8 June 1988
Resolved
REPLACE LIFE RINGS PORT AND STARBOARD FORECASTLE AND ON DECK HOUSE FORWARD BULKHEAD.
Condition: Unknown
Due 8 June 1988
Resolved 8 June 1988
Unknown
Issued 8 June 1988
Resolved
PROVIDE COVER FOR HEAD VENT.
Condition: Unknown
Due 8 June 1988
Resolved 8 June 1988
Unknown
Issued 8 June 1988
Resolved
CLEAN ALL BATTER TERMINALS AS NECESSARY AND PROVIDE BATTERY TERMINAL FOR ANCHOR WINDLASS ENGINE.
Condition: Unknown
Due 8 June 1988
Resolved 8 June 1988
Construction/Loadline
Issued 9 July 1987
Resolved
CROP & RENEW THE INBOARD (PORT SIDE OF CENTER LINE SWASH BULKHEAD APPROX LAST 18") LOWER TRUSS CORD IN THE #3 CENTER BALLAST TANK.
Condition: Unknown
Due 9 July 1987
Resolved 9 July 1987
Fire Fighting
Issued 9 July 1987
Resolved
TEST ALL FIRE HOSES.
Condition: Unknown
Due 9 July 1987
Resolved 9 July 1987
Construction/Loadline
Issued 9 July 1987
Resolved
CROP & RENEW THE AFT 18" (APPROX) OF EACH BOTTOM LONG IN #3 PORT VOID.
Condition: Unknown
Due 9 July 1987
Resolved 9 July 1987
Construction/Loadline
Issued 9 July 1987
Resolved
REPAIR/RENEW BOTTOM STBD FWD SKID BARS IN WAY OF BOTTOM SHELL PLATING.
Condition: Unknown
Due 9 July 1987
Resolved 9 July 1987
Electrical
Issued 9 July 1987
Resolved
PROVIDE AN OPERATIONAL TEST OF 50KW GENERATOR.
Condition: Unknown
Due 9 July 1987
Resolved 9 July 1987
Fire Fighting
Issued 9 July 1987
Resolved
PROVE OPERATION OF FIRE PUMP.
Condition: Unknown
Due 9 July 1987
Resolved 9 July 1987
Construction/Loadline
Issued 5 June 1986
Resolved
REMOVE WATER FROM THE 2 AFTER VOIDS.
Condition: Unknown
Due 5 June 1986
Resolved 5 June 1986
Electrical
Issued 5 June 1986
Resolved
PROVIDE GLOBES FOR 4 LIGHTING FIXTURES IN THE 100 KW GENERATOR ROOM.
Condition: Unknown
Due 5 June 1986
Resolved 5 June 1986
Electrical
Issued 5 June 1986
Resolved
REMOVE OR INSTALL LIGHTING FIXTURE AT FITTING IN 100 KW GENERATOR ROOM JUSTINSIDE AND OVERHEAD OF ENTRANCE.
Condition: Unknown
Due 5 June 1986
Resolved 5 June 1986
Construction/Loadline
Issued 5 June 1986
Resolved
REMOVE TORN METAL PLATE COVERING HYDRAULIC LINES ON FWD. CARGO CRANE.
Condition: Unknown
Due 5 June 1986
Resolved 5 June 1986
Construction/Loadline
Issued 5 June 1986
Resolved
REPACK STUFFING BOX PACKING GLAND ON STARBOARD MAIN ENGINE SHAFT.
Condition: Unknown
Due 5 June 1986
Resolved 5 June 1986
Electrical
Issued 5 June 1986
Resolved
REMOVE DEAD END WIRING FROM RUBBER COVERED TERMINAL IN WORKSHOP.
Condition: Unknown
Due 5 June 1986
Resolved 5 June 1986
Electrical
Issued 5 June 1986
Resolved
REMOVE VERY RIGGED EXTENSION CABLE FOR FREEZER AND HARDWIRE TO JUNCTION BOXWITH MARINE APPROVED CABLE.
Condition: Unknown
Due 5 June 1986
Resolved 5 June 1986
Electrical
Issued 5 June 1986
Resolved
REPLACE COVER ON STBD 50 KW GENERATOR PANEL.
Condition: Unknown
Due 5 June 1986
Resolved 5 June 1986
Electrical
Issued 5 June 1986
Resolved
REPLACE COVER ON SWITCH BOX FOR JABSCO BILGE PUMP.
Condition: Unknown
Due 5 June 1986
Resolved 5 June 1986
Accommodation/Occupational Safety
Issued 5 June 1986
Resolved
PROVIDE PLUG FOR HOT WATER HEATER PIPING IN HEAD.
Condition: Unknown
Due 5 June 1986
Resolved 5 June 1986
Electrical
Issued 5 June 1986
Resolved
PROVIDE GLOBE FOR LIGHTING FIXTURE IN MANIFOLD SPACE JUST FORWARD OF STBD MAIN ENGINE.
Condition: Unknown
Due 5 June 1986
Resolved 5 June 1986
Electrical
Issued 5 June 1986
Resolved
REMOVE ALL DEAD END WIRING IN ENGINE ROOM AS POINTED OUT TO OWNER.
Condition: Unknown
Due 5 June 1986
Resolved 5 June 1986
Engineering
Issued 5 June 1986
Resolved
PROPERLY RECONNECT HOT LEAD TO STARTER ON CENTER MAIN ENGINE.
Condition: Unknown
Due 5 June 1986
Resolved 5 June 1986
Fire Fighting
Issued 5 June 1986
Resolved
REPACK MAIN FIRE PUMP PACKING GLAND.
Condition: Unknown
Due 5 June 1986
Resolved 5 June 1986
Electrical
Issued 5 June 1986
Resolved
PROVIDE COVER FOR FUEL TRANSFER PUMP MOTOR JUNCTION BOX.
Condition: Unknown
Due 5 June 1986
Resolved 5 June 1986
Accommodation/Occupational Safety
Issued 17 June 1985
Resolved
REPAIR POTABLE PIPING IN #5 VOIDS.
Condition: Unknown
Due 17 June 1985
Resolved 17 June 1985
Construction/Loadline
Issued 17 June 1985
Resolved
CROP AND RENEW BOW SKID BARS.
Condition: Unknown
Due 17 June 1985
Resolved 17 June 1985