MAURY USCG vessel records Sign in
← All vessels

MANZANARES

MANZANARES is a 2006 freight ship. The Coast Guard has recorded 20 inspections since 2008, most recently in February 2012, along with 13 deficiencies and 4 operational controls.

Records from 2008 to 2012. Most recent: inspection, 21 February 2012.

Built
2006
Last inspected
21 February 2012
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9331804 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
862333
Flag
PANAMA
—
Maury page id
psix-862333

Inspections, by type

…with no type recorded8
Years with a record 5 calendar years (2008–2012)
The 20 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 14 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it5000 - Regulatory (Subpart C or D), Gross Ton
5000 - Convention (Subpart B), Gross Ton
2405 - Regulatory (Subpart C or D), Net Ton
2405 - Convention (Subpart B), Net Ton
70734 - Dead Weight, Ton
22 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 20

21 February 2012 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4248622
11 January 2012 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 4222817
9 January 2012 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4221760
4 January 2012 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4218694
26 September 2011 ISPS II Exam · PII Safety Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 4149911
1 July 2011 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4063992
23 December 2010 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3915487
2 December 2010 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3902514
1 December 2010 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3902459
11 December 2009 Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3648424
10 December 2009 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3654526
8 December 2009 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3646343
5 December 2009 Administrative Inspection · Examination of Repairs · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3645142
23 March 2009 PII Safety Exam · ISPS II Exam · Ballast Water Examination · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3438405
23 March 2009 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3440741
16 April 2008 Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3184754
15 March 2008 ISPS II Exam · Deficiency Check · PII Safety Exam · Ballast Water Examination · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3160432
15 March 2008 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3165195
25 January 2008 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3134273
22 January 2008 Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3142667

Deficiency record · 13

Fire Fighting › Structural - A Class Divisions › Doors
Issued 20 September 2011 Resolved
All doors leading into engine room escape trunk were found to not self close. In addition the door leading into the purifying room was tied back. Class is to make attest to repairs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 October 2011
Resolved 11 January 2012
Resolution: RECIEVED CLASS REPORT CLEARING DEFICIENCY
Stability › Watertight Integrity › General
Issued 11 December 2009 Resolved
Vessel ran aground during departure from Tampa. Vessel is required to have divers to determine if there were any punctures to the hull.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 October 2010
Engineering › Shafting/Propeller Arrangements › Propeller (controllable pitch)
Issued 11 December 2009 Resolved
During transit to International Ship Repair it was observed the the CPP system was not functioning correctly.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 December 2009
Engineering › Steering Gear System › Rudder
Issued 11 December 2009 Resolved
Vessel may have damaged steering while enroute to berth in Tampa. Vessel must have divers inspect for any damage.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 October 2010
Engineering › Diesel Engine (propulsion-direct drive) › Injector (fuel injection)
Issued 7 December 2009 Resolved
O-rings on two fuel injectors cracked allowing fuel oil to leak out. This fuel went in to a reservoir as designed and triggered an alarm. SOLAS 2004 Consolidated Edition, Chapter II-1, Reg. 26
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 December 2009
Resolution: The engineers received the alarm and replaced the two faulty fuel injectors. Successful propulsion tests were completed after the fuel injectors were replaced.
Engineering › Generator (propulsion-electric) › Generator Voltage Regulator Circuitry
Issued 16 April 2008 Resolved
Vessels #1 Generator has an in-operable governor causing the gen.-set to drop the electricle load.
Action required: 705 - Other - as specified
Resolved 17 April 2008
Resolution: All three generators working in manual mode. Vessel placed order for circuit breaker that will not be available for 20 days. However, generators are in working condition and the engine room is maintained on a 24 hour watch.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 1 February 2008 Resolved
Noted the following during a def check: STBD side void #3 after blkhd below the man hole has been repaired on both sides with a metal substitute. Also found port side longitudinal stiffener in the same area as the STBD side to be cracked. Make permanent repairs to the satisfaction of class prior to the nest US port after sailing foreign.
Action required: 15 - Rectify deficiencies by next port
Resolved 29 February 2008
Resolution: Received class report of satisfactory repair.
Lifesaving › Rescue Boat › Markings
Issued 25 January 2008 Resolved
SOLAS Reflective Tape on vessel's rescue boat was found to be worn and in poor condition. Vessel is to replace reflective tape within 14 days to the satisfaction of class.
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 February 2008
Resolved 30 January 2008
Resolution: deficiency cleared.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 25 January 2008 Resolved
Noted that the required markings on vessel's lifebuoys are worn and unreadable. Vessel is to renew markings on lifebuoys within 14 days to the satisfaction of class.
Action required: 705 - Other - as specified
Due 8 February 2008
Resolved 30 January 2008
Resolution: Deficiency cleared
Lifesaving › Lifejacket/PFD (Type III) › Lights
Issued 25 January 2008 Resolved
Noted that 2 lights on crewman's life jackets did not work. Vessel is to replace inoperable lights on PFD's prior to departure from St. Croix to the satisfaction of the CG.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 January 2008
Resolution: Deficiency cleared
Documentation › Certificates/Documents › Minimum Safe Manning Document
Issued 25 January 2008 Resolved
Noted that the vessel's Minimum Safe Manning document is listed as an "interim certificate" and was issued in 2006. Vessel must have full term permanent document on board prior to departure from St. Croix to the satisfaction of USCG prior to departure from St. Croix.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 29 February 2008
Resolved 29 February 2008
Resolution: Sec San Juan accepted interim certificate as approved by administration until permanent certificate is issued.
Engineering › Thrusters › Piping
Issued 25 January 2008 Resolved
Noted a softpatch on supply line to the bow thruster's day tank. Vessel is to repair to the satisfaction of class prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 January 2008
Resolution: deficiency cleared.
Deck/Cargo › Ballast › Tank
Issued 25 January 2008 Resolved
Noted a saltwater leak in the port and stbd side of Void #1. Class is to determine cause and provide proposal of repair (if necessary) to USCG.
Action required: 705 - Other - as specified
Due 29 February 2008
Resolved 29 February 2008
Resolution: Received satisfactory report from Administration.

Ownership record