Records from 2016 to 2025. Most recent: inspection, 14 February 2025.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 14 February 2025
Resolved
The purpose of this regulation is to maintain and monitor the effectiveness of the fire safety measures the ship is provided with. For this purpose, the following functional requirements shall be met: fire protection systems and fire-fighting systems and appliances shall be maintained ready for use. PSCO observed air leak before accumulator bottle in pneumatic quick closing valves in fire control room manifold.
74SOLAS(20)II-2/14.1, Code 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 February 2025
Resolution: PSC NOLA received a class report/technician’s report/proper documentation from issuing entity satisfying the requirement.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 14 February 2025
No resolution recorded
The side scuttles, together with their glasses, if fitted, shall be of substantial and approved construction. PSCO observed a shattered window in officer mess room STBD side.
ICLL I/23, Code 50ac
Action required: 50 - Rectify deficiencies w/in 30 days
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 14 February 2025
Resolved
The angular position of the rudder shall be recognizable in the steering gear compartment. PSCO observed rudder angle indicator in steering gear did not match reading on the bridge. It reads 3 degrees STBD of bridge.
74SOLAS(09) II-1/29.11.2, Code 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 February 2025
Resolution: PSC NOLA received a class report/technician’s report/proper documentation from issuing entity satisfying the requirement.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 14 February 2025
Resolved
All ships of 500 gross tonnage and upwards shall have means to display rudder angle readable from the conning position. PSCO observed rudder angle indicator on bridge wings not reading accurately.
74SOLAS(20) V/19.2.5.4, Code 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 February 2025
Resolution: PSC NOLA received a class report/technician’s report/proper documentation from issuing entity satisfying the requirement.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 February 2025
Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board. PSCO observed a leak on the sea water outlet pipe on the #1 low temperature heat exchanger.
74SOLAS(09) II-1/26.1, Code 16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2025
Resolved 25 February 2025
Resolution: PSC NOLA received a class report/technician’s report/proper documentation from issuing entity satisfying the requirement.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 February 2025
Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. PSCO observed a jacket water leak on the main engine #6 unit.
74SOLAS(09) II-1/26.1, Code 16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2025
Resolved 25 February 2025
Resolution: PSC NOLA received a class report/technician’s report/proper documentation from issuing entity satisfying the requirement.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 14 February 2025
Resolved
The construction of doors and door frames in "A" class divisions, with the means of securing them when closed, shall provide resistance to fire as well as to the passage of smoke and flame equivalent to that of the bulkheads in which the doors are situated. PSCO observed the fire tight door to the electrical store room was not self-closing.
74SOLAS (20) II-2/9.4.1.1.2, Code 10c
Action required: 10 - Deficiency Rectified
Resolved 14 February 2025
Resolution: Rectified on the spot.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 February 2025
Resolved
Electrical installations shall be such that the safety of passengers, crew and ship from electrical hazards will be ensured. PSCO oberserved several spare breakers on the switchboard in the on position.
74SOLAS(09) II-1/40.1.3, Code 10c
Action required: 10 - Deficiency Rectified
Resolved 14 February 2025
Resolution: Rectified on the spot.