SCREAMING EAGLE SPORTS

SCREAMING EAGLE SPORTS is a 2006 passenger vessel (inspected). The Coast Guard has recorded 27 inspections since 2006, most recently in April 2026, along with 46 deficiencies and 1 casualty investigation in 2008.

Records from 2006 to 2026. Most recent: inspection, 27 April 2026.

Built
2006
Last inspected
27 April 2026
Documentation
Case Pending · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDN2547
862391
Flag
UNITED STATES
368263150
Maury page id
psix-862391

Inspections, by type

…with no type recorded2
Years with a record 17 calendar years (2006–2026)
The 27 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)33.0 ft × 10.0 ft × 5.0 ft
Registered tonnagegross 11 / net 8
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderLYNCH'S BOAT MANUFACTURING INC · LAKE HAVASU CITY, AZ, UNITED STATES · built 2006
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portDESTIN, FL
Trade endorsementsCoastwise, unrestricted
DocumentationCase Pending · issued 19 March 2025 · expires 30 April 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it11 - Simplified, Gross Ton
8 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDN2547MMSI 368263150 · active · compulsorily equipped · granted 17 June 2022, expires 17 June 2032 · licensed under a name not among this hull’s recorded names (not shown)
WDH5557MMSI 367629080 · expired · voluntarily equipped · granted 24 June 2014, cancelled 24 August 2024 · licensed under a name not among this hull’s recorded names (not shown)
WDF4234MMSI 367449520 · expired · compulsorily equipped · granted 28 April 2010, cancelled 4 July 2020 · licensed under a name not among this hull’s recorded names (not shown)
WDD5848MMSI 367164760 · expired · compulsorily equipped · granted 3 February 2007, cancelled 8 April 2017
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 27

27 April 2026 Administrative Inspection · Annual Inspection · Vessel Attendance · Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8357248
28 January 2026 Drydock Exam · Internal Structural Exam · Vessel Attendance · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8303636
20 March 2025 Administrative Inspection · Special Consideration · Annual Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8096943
12 September 2024 Administrative Inspection · Special
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8001362
18 March 2024 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7877232
6 March 2023 Annual Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7646430
6 April 2022 Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7427149
23 March 2021 Administrative Inspection · Annual Inspection · DAPI Audit · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7161605
9 June 2020 Administrative Inspection · Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6979007
4 April 2019 COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6649318
19 March 2019 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6646735
25 October 2018 Administrative Inspection · Damage Survey
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6570775
10 May 2018 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6404217
21 September 2017 Administrative Inspection
Administrative · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6271922
20 June 2017 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6177681
30 March 2017 Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6112570
25 August 2016 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5979723
15 September 2015 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5719154
14 June 2014 Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 4889979
10 June 2014 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 4891368
6 April 2009 Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3451676
29 October 2008 Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3351999
28 May 2008 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3211171
28 May 2008 Type not recorded
No type recorded · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3226047
8 February 2007 Deficiency Check · Initial Certification
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2864579
27 October 2006 Plan Review "T" Boat
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2809294
8 February 2006 Construction Oversight
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2870616

Deficiency record · 46

05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 24 March 2025 Resolved
The vessel must have a Cat I EPIRB properly installed to float free. The EPIRB hydro release is expired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 1 June 2026
Resolution: Corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 24 March 2025 Resolved
Vessel must be equipped with the correct number of flares for the route specified on the COI. The vessel had 7 of 12 available.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 1 June 2026
Resolution: Corrected.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 18 March 2024 Resolved
The pre-engineered fire extinguishing system must be installed in accordance with the manufacturer's instructions. The Port main engine doesn't secure when activated and the override to restart function does not operate as designed.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 March 2024
Resolution: Corrected.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 6 April 2022 Resolved
Provide proof of vessels pre-engineered fire extinguishing system annual service.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 April 2022
Resolution: Servicing report provided.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 April 2022 Resolved
Properly adjust both fuel tank shut off valves.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 June 2022
Resolution: Witnessed f/o valves close when remotely pulled.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 6 April 2022 Resolved
Provide proof of Drug and Alcohol testing program enrollment for all crew members.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 April 2022
Resolution: Consortium list provided.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 6 April 2022 Resolved
Provide proof of current navigational publications (tide tables, Coast Pilot, Charts).
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 April 2022
Resolution: All navigational publications provided.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 6 April 2022 Resolved
Provide proof of a valid COD.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 June 2022
Resolution: Inspected vessel current COD.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 23 March 2021 Resolved
Vessel is required to carry an operational waterlight. Additionally, this vessel is required to maintain a synthetic line for the life ring. The vessel's life ring currently contains a cotton line. The waterlight for the life ring is currently in need of a new battery and non-operational.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 June 2022
Resolution: Witnessed new line installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 March 2021 Resolved
Fuel shut off valve at the operating station is currently placed in an inoperable condition. Provide proof that fuel shut off valve is operational and in working condition.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 June 2022
Resolution: Witnessed vessel rep close f/o valves remotely.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 23 March 2021 Resolved
Vessel's EPIRB registration and hydrostatic release have both exceeded their expiration date. Provide proof of new registration and hydrostatic release prior to operating greater than 3NM.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 6 April 2022
Resolution: New EPIRB and hydro installed.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 23 March 2021 Resolved
Replace/Correct stern Navigational Light. Due to recent maintenance, the vessel's stern Navigation Light is in inoperable condition. Provide proof of newly installed and operational Navigational Light.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 April 2021
Resolved 6 April 2022
Resolution: New fixture installed and tested. All sat.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 23 March 2021 Resolved
Vessel does not maintain an FCC Radio Safety Certificate. Provide proof of newly acquired FCC Radio Safety Certificate once received.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 April 2021
Resolved 6 April 2022
Resolution: Valid certificate provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 March 2021 Resolved
Provide and post new Life Jacket donning placards. The vessel's current set are worn, tattered, and un-legible for passengers. Provide proof of newly acquired donning placards.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 April 2021
Resolved 6 April 2022
Resolution: New donning placard installed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 March 2021 Resolved
Provide ventilation cover for Engine Room, ensure proper seal. Vessel currently does not maintain a ventiliation cover onboard.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 April 2021
Resolved 6 April 2022
Resolution: Vent covers provided.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 March 2021 Resolved
Provide proof of newly serviced portable fire-extinguishers. The current set maintained onboard exhibit high levels of corrosion. Provide newly acquired servicing report or proof of newly acquired portable fire-extinguishers.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 April 2021
Resolved 6 April 2022
Resolution: New extinguishers provided.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Health protection, medical care?)
Issued 23 March 2021 Resolved
Repair broken windshield at the vessel's operating station. The current windshield exhibits a large missing piece. Provide proof that the repair has been completed or that the windshield has been removed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 April 2021
Resolved 6 April 2022
Resolution: Damaged windshield removed.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 23 March 2021 Resolved
Re-locate EPIRB. The current EPIRB is placed under the vessel's windshield at the operating station, preventing its ability to float freely.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 April 2021
Resolved 6 April 2022
Resolution: EPIRB relocated to a new float free location.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 9 June 2020 Resolved
Repair or replace loose fire boy over-ride plug and prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 June 2020
Resolved 14 July 2020
Resolution: Owner repaired loose fire boy over-ride plug and prove proper operation.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 9 June 2020 Resolved
Provide proper operation of life ring light.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 June 2020
Resolved 14 July 2020
Resolution: Owner provided proper operation of life ring light.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 9 June 2020 Resolved
Properly install stern light prior to operating in reduced visibility or from dusk to dawn.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 June 2020
Resolved 14 July 2020
Resolution: Owner properly installed stern light.
01 - Certificates & Documentation › 012 - Crew Certificates › Doc evidence for personnel on passenger ships
Issued 9 June 2020 Resolved
Provide high speed craft senior deck hand instruction and designation letter.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 June 2020
Resolved 14 July 2020
Resolution: Owner provided high speed craft senior deck hand instruction and designation letter.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 June 2020 Resolved
Provide proof of three fire buckets.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 June 2020
Resolved 14 July 2020
Resolution: Owner provided proof of three fire buckets.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 June 2020 Resolved
Repair three fractures in canopy.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 July 2020
Resolved 14 July 2020
Resolution: Owner repaired the three fractures in canopy.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 June 2020 Resolved
Repair old anchor bow holes.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 June 2020
Resolved 14 July 2020
Resolution: Owner repaired old anchor bow holes.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 20 June 2017 Resolved
Provide proof of Consorsum enrollment
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 21 June 2017
Resolution: Provided
Communications › Alarms/Indicators › High Water Alarm
Issued 20 June 2017 Resolved
Provide visual high water indicator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 21 June 2017
Personnel › Training › Fire Fighting Basic
Issued 28 May 2008 Resolved
DEMONSTRATE ALL EMERGENCY DRILLS IN THE PRESENCE OF A CG MARINE INSPECTOR
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 June 2008
Resolution: CLEARED
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 28 May 2008 Resolved
PROVIDE WATERLIGHTFOR RING BUOY AND PROPERLY MOUNT WITH APPROVED BRACKET.
Action required: 705 - Other - as specified
Due 5 June 2008
Resolved 4 June 2008
Resolution: CLEARED
Navigation › Collision/Grounding Avoidance › Radar
Issued 28 May 2008 Resolved
MAKE PERMANENT REPAIRS TO INOPERABLE RADAR.
Action required: 705 - Other - as specified
Due 28 June 2008
Resolved 19 June 2008
Resolution: Repair was sat and radar was operational.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 28 May 2008 Resolved
PROVIDE ORIGINAL, NON- LAMINATED USCG MASTERS LICENCE
Action required: 705 - Other - as specified
Due 28 June 2008
Resolved 19 June 2008
Resolution: Original license was presented to inspector-sat.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 28 May 2008 Resolved
DEMONSTRATE PROPER OPERATION OF THE FIXED FIRE FIGHTING SYSTEM
Action required: 705 - Other - as specified
Due 5 June 2008
Resolved 4 June 2008
Resolution: Witnessed proper operation of the fixed system.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 28 May 2008 Resolved
PROVIDE 60' NON-KINKING LINE FOR THE RING BUOY.
Action required: 705 - Other - as specified
Due 5 June 2008
Resolved 19 June 2008
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 28 May 2008 Resolved
REPLACE PROTECTIVE COVERING FOR THE ELECTRONIC PANEL
Action required: 705 - Other - as specified
Due 10 June 2008
Resolved 19 June 2008
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 28 May 2008 Resolved
BLANK OFF UNUSED PANEL AT THE OPERATING STATION.
Action required: 705 - Other - as specified
Due 5 June 2008
Resolved 19 June 2008
Construction/Loadline › Hull › Keel
Issued 28 May 2008 Resolved
MAKE HULL AVAILABLE FOR INSPECTION
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 June 2008
Resolution: Hull was made available for inspection and no damage was visible.
Navigation › Piloting/Steering › Maneuvering Information Fact Sheet
Issued 28 May 2008 Resolved
PROVIDE CHART FOR HURRICANE BAY APPROACH
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 June 2008
Resolution: CLEARED
Documentation › Markings/Placards › Warning Signs
Issued 8 February 2007 Resolved
Post emergency broadcast placard
Action required: 705 - Other - as specified
Resolved 15 February 2007
Resolution: CLEARED
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 8 February 2007 Resolved
Properly mark ring buoy.
Action required: 705 - Other - as specified
Resolved 15 February 2007
Resolution: CLEARED
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 8 February 2007 Resolved
Provide full complement of lifejackets
Action required: 705 - Other - as specified
Resolved 15 February 2007
Resolution: CLEARED
Documentation › Certificates/Documents › FCC SSL
Issued 8 February 2007 Resolved
Provide FCC Safety Radio Telephony Certificate.
Action required: 705 - Other - as specified
Resolved 15 February 2007
Resolution: CLEARED
Engineering › Bilge Water Management System › Pump
Issued 8 February 2007 Resolved
Make all bilge high level alarms operational
Action required: 705 - Other - as specified
Resolved 15 February 2007
Resolution: CLEARED
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 8 February 2007 Resolved
Post all required Certificates.
Action required: 705 - Other - as specified
Resolved 15 February 2007
Resolution: CLEARED
Fire Fighting › Fixed CO2 Fire Extinguishing System › Tanks
Issued 8 February 2007 Resolved
Provide means of closing air vents upon discharge of Fixed firefighting system.
Action required: 705 - Other - as specified
Resolved 15 February 2007
Resolution: CLEARED
Lifesaving › Hand Flares › Quantity
Issued 31 January 2007 Resolved
Provide three additional flares to make for full complement
Action required: 705 - Other - as specified
Resolved 15 February 2007
Resolution: CLEARED
Engineering › Fuel Oil Service System › Filter
Issued 31 January 2007 Resolved
Install fuel flash bulbs under both fuel filters.
Action required: 705 - Other - as specified
Resolved 15 February 2007
Resolution: CLEARED

Casualty record · 1

28 May 2008Routine · role: Involved in a Marine Casualty · activity 3226047
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

SEA ROCKET USA (2008). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.