Records from 2008 to 2026. Most recent: inspection, 27 April 2026.
Everything above is free. The detail below — the inspection history, the deficiency record, the recorded names, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 17
27 April 2026
Administrative Inspection · Annual Inspection · Vessel Attendance · Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8357248
28 January 2026
Drydock Exam · Internal Structural Exam · Vessel Attendance · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8303636
20 March 2025
Administrative Inspection · Special Consideration · Annual Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8096943
12 September 2024
Administrative Inspection · Special
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8001362
18 March 2024
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7877232
6 March 2023
Annual Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7646430
6 April 2022
Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7427149
23 March 2021
Administrative Inspection · Annual Inspection · DAPI Audit · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7161605
9 June 2020
Administrative Inspection · Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6979007
4 April 2019
COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6649318
19 March 2019
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6646735
25 October 2018
Administrative Inspection · Damage Survey
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6570775
10 May 2018
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6404217
21 September 2017
Administrative Inspection
Administrative · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6271922
20 June 2017
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6177681
30 March 2017
Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6112570
25 August 2016
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5979723
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 24 March 2025
Resolved
The vessel must have a Cat I EPIRB properly installed to float free. The EPIRB hydro release is expired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 1 June 2026
Resolution: Corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 24 March 2025
Resolved
Vessel must be equipped with the correct number of flares for the route specified on the COI. The vessel had 7 of 12 available.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 1 June 2026
Resolution: Corrected.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 18 March 2024
Resolved
The pre-engineered fire extinguishing system must be installed in accordance with the manufacturer's instructions. The Port main engine doesn't secure when activated and the override to restart function does not operate as designed.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 March 2024
Resolution: Corrected.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 6 April 2022
Resolved
Provide proof of vessels pre-engineered fire extinguishing system annual service.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 April 2022
Resolution: Servicing report provided.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 April 2022
Resolved
Properly adjust both fuel tank shut off valves.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 June 2022
Resolution: Witnessed f/o valves close when remotely pulled.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 6 April 2022
Resolved
Provide proof of Drug and Alcohol testing program enrollment for all crew members.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 April 2022
Resolution: Consortium list provided.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 6 April 2022
Resolved
Provide proof of current navigational publications (tide tables, Coast Pilot, Charts).
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 April 2022
Resolution: All navigational publications provided.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 6 April 2022
Resolved
Provide proof of a valid COD.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 June 2022
Resolution: Inspected vessel current COD.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 23 March 2021
Resolved
Vessel is required to carry an operational waterlight. Additionally, this vessel is required to maintain a synthetic line for the life ring. The vessel's life ring currently contains a cotton line. The waterlight for the life ring is currently in need of a new battery and non-operational.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 June 2022
Resolution: Witnessed new line installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 March 2021
Resolved
Fuel shut off valve at the operating station is currently placed in an inoperable condition. Provide proof that fuel shut off valve is operational and in working condition.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 June 2022
Resolution: Witnessed vessel rep close f/o valves remotely.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 23 March 2021
Resolved
Vessel's EPIRB registration and hydrostatic release have both exceeded their expiration date. Provide proof of new registration and hydrostatic release prior to operating greater than 3NM.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 6 April 2022
Resolution: New EPIRB and hydro installed.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 23 March 2021
Resolved
Replace/Correct stern Navigational Light. Due to recent maintenance, the vessel's stern Navigation Light is in inoperable condition. Provide proof of newly installed and operational Navigational Light.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 April 2021
Resolved 6 April 2022
Resolution: New fixture installed and tested. All sat.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 23 March 2021
Resolved
Vessel does not maintain an FCC Radio Safety Certificate. Provide proof of newly acquired FCC Radio Safety Certificate once received.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 April 2021
Resolved 6 April 2022
Resolution: Valid certificate provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 March 2021
Resolved
Provide and post new Life Jacket donning placards. The vessel's current set are worn, tattered, and un-legible for passengers. Provide proof of newly acquired donning placards.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 April 2021
Resolved 6 April 2022
Resolution: New donning placard installed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 March 2021
Resolved
Provide ventilation cover for Engine Room, ensure proper seal. Vessel currently does not maintain a ventiliation cover onboard.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 April 2021
Resolved 6 April 2022
Resolution: Vent covers provided.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 March 2021
Resolved
Provide proof of newly serviced portable fire-extinguishers. The current set maintained onboard exhibit high levels of corrosion. Provide newly acquired servicing report or proof of newly acquired portable fire-extinguishers.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 April 2021
Resolved 6 April 2022
Resolution: New extinguishers provided.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Health protection, medical care?)
Issued 23 March 2021
Resolved
Repair broken windshield at the vessel's operating station. The current windshield exhibits a large missing piece. Provide proof that the repair has been completed or that the windshield has been removed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 April 2021
Resolved 6 April 2022
Resolution: Damaged windshield removed.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 23 March 2021
Resolved
Re-locate EPIRB. The current EPIRB is placed under the vessel's windshield at the operating station, preventing its ability to float freely.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 April 2021
Resolved 6 April 2022
Resolution: EPIRB relocated to a new float free location.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 9 June 2020
Resolved
Repair or replace loose fire boy over-ride plug and prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 June 2020
Resolved 14 July 2020
Resolution: Owner repaired loose fire boy over-ride plug and prove proper operation.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 9 June 2020
Resolved
Provide proper operation of life ring light.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 June 2020
Resolved 14 July 2020
Resolution: Owner provided proper operation of life ring light.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 9 June 2020
Resolved
Properly install stern light prior to operating in reduced visibility or from dusk to dawn.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 June 2020
Resolved 14 July 2020
Resolution: Owner properly installed stern light.
01 - Certificates & Documentation › 012 - Crew Certificates › Doc evidence for personnel on passenger ships
Issued 9 June 2020
Resolved
Provide high speed craft senior deck hand instruction and designation letter.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 June 2020
Resolved 14 July 2020
Resolution: Owner provided high speed craft senior deck hand instruction and designation letter.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 June 2020
Resolved
Provide proof of three fire buckets.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 June 2020
Resolved 14 July 2020
Resolution: Owner provided proof of three fire buckets.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 June 2020
Resolved
Repair three fractures in canopy.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 July 2020
Resolved 14 July 2020
Resolution: Owner repaired the three fractures in canopy.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 June 2020
Resolved
Repair old anchor bow holes.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 June 2020
Resolved 14 July 2020
Resolution: Owner repaired old anchor bow holes.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 20 June 2017
Resolved
Provide proof of Consorsum enrollment
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 21 June 2017
Resolution: Provided
Communications › Alarms/Indicators › High Water Alarm
Issued 20 June 2017
Resolved
Provide visual high water indicator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 21 June 2017