MAURY USCG vessel records Sign in
← All vessels

ELM GALAXY

ELM GALAXY is a 2006 tank ship. The Coast Guard has recorded 28 inspections since 2006, most recently in May 2026, along with 5 deficiencies — 1 with no resolution recorded — and 11 operational controls.

Records from 2006 to 2026. Most recent: inspection, 21 May 2026.

Built
2006
Last inspected
21 May 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9331256 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
862447
Flag
PANAMA
—
Maury page id
psix-862447

Inspections, by type

…with no type recorded15
Years with a record 11 calendar years (2006–2026)
The 28 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it12105 - Convention (Subpart B), Gross Ton
26381 - Displacement, Metric Ton
20854 - Dead Weight, Metric Ton
6665 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 28

21 May 2026 Administrative Inspection · COC-CHEM & TVE Renew · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8378044
5 February 2023 PSC B · COC-CHEM & TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7632155
20 August 2021 PSC B · COC-CHEM & TVE Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7289108
8 June 2021 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7219910
15 February 2021 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7140964
14 February 2021 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7140684
25 January 2021 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7130419
10 July 2020 COC-CHEM & TVE Renew · PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7002968
21 July 2017 Ballast Water Examination · COC-CHEM & TVE Annual · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6212806
18 June 2016 ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Renew
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5910195
7 October 2014 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5000648
2 October 2014 COC-CHEM & TVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4997458
12 August 2011 ISPS II Exam · COC-CHEM Renew · Ballast Water Examination
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4109335
9 August 2011 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4110295
10 November 2008 MARPOL Annex V Examination · MARPOL Annex I Examination · MARPOL Annex II Examination · Ballast Water Examination · COC-CHEM Renew · ISPS III Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3359128
21 September 2008 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3329195
17 September 2008 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3327000
4 June 2008 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3227599
25 May 2008 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3216681
16 May 2008 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3208038
3 June 2007 Random ISPS/MTSA-No PSC
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2949904
31 May 2007 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2947925
30 May 2007 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2946245
27 May 2007 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2941993
6 February 2007 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2868030
5 February 2007 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2867534
1 February 2007 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2865623
30 October 2006 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2810490

Deficiency record · 5

02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 21 May 2026 No resolution recorded
Each vessel vapor connection flange face must have a permanent stud projecting outward that has a 12.7 millimeter diameter and at least 25.4 millimeter long. PSCO observed permenantly affixed stud on vapor line #2 starboard side manifold chizzled off. 46CFR39.2001(j)
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Lifesaving › Rescue Boat › Propulsion Engine
Issued 18 June 2016 Resolved
0615: Before the ship leaves port and at all times during the voyage, all life saving appliances shall be in working order and ready for immediate use. The rescue boat engine is not working per the operators manual. Cooling water is not coming out of the cooling water check point. Engine is not being maintained as per page 30 of the operating manual, SOLAS (14) III.20.2, 17 ABC.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 June 2016
Resolved 20 June 2016
Resolution: Repaired by Technician and testing witnessed by the Attending Classification Representative.
Documentation › Logs/Records › Ballast Water Logs/Records
Issued 18 June 2016 Resolved
2510: Vessel must maintain a Ballast Water Management Plan that has been developed specifically for the vessel. Crew is not maintaining a Bio-Fouling Plan, 33CFR2050(g)/ IMO Resolution 207(62), 10C.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 June 2016
Resolved 18 June 2016
Resolution: Discussed subject with the [name withheld] and Chief Engineer.
Lifesaving › Launching Appliances › Davit
Issued 2 October 2014 Resolved
0635 - All life-saving appliances shall be in working order and ready for immediate use. While testing the operation of the Rescue Boat davit launch system, the forward davit cable was damaged which rendered the Rescue Boat launch davit system inoperable. 74SOLAS(09) III/20.2 ; 17ac
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 October 2014
Resolution: 07OCT14: Recieved report and reciept from class attesting to the replacement of the damaged wire rope with a new certified wire rope. The new wire rope was tested and found to be in compliance. Rescue Boat launch system is back to normal condition.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 2 October 2014 Resolved
0735 - Fire-fighting outfits shall consist of protective clothing of material to protect the skin from the heat radiating from the fire and from burns and scalding by steam. Two fire-fighting outfits were found with delaminating of heat protection material. 74 SOLAS 04 con. II-2/10.10.1& FSS Code 3/2.1.1.1 ; 40ac
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 7 October 2014
Resolution: 07OCT14: Classification Society provided receipt of two new Firemen Outfits were provided onboard.

Ownership record