17 April 2026
COI Inspection · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8351567
9 June 2025
Hull Examination · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8161902
20 August 2024
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8091451
1 May 2023
Annual Inspection · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7831488
11 July 2022
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7504024
5 April 2021
Examination of Repairs · Drydock Exam · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7164974
22 June 2020
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6981001
9 April 2020
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6937313
5 June 2019
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6704986
10 April 2018
Hull Examination · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6388744
15 May 2017
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6147975
25 March 2016
COI Inspection · DAPI Audit · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5838933
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 17 April 2026
Resolved
A vessel to which this subchapter applies may not be operated without a valid certificate of inspection. Vessels COI is expired.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 April 2026
Resolution: Vessel completed COI inspection
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 June 2025
Resolved
Provide vessel's life ring with 60' of line. Cleared on the spot.
Action required: 705 - Other - as specified
Resolved 9 June 2025
Resolution: Corrected on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 June 2025
Resolved
Provide vessel's life ring with retro reflective tape.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 June 2025
Resolution: Received photos of retro tape.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 June 2025
Resolved
Both main engine fuel tank hoses were found to be deteriorated and in need of replacement. Replace both fuel hoses with gasoline rated hoses.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 June 2025
Resolution: Received photos of new hoses.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 June 2025
Resolved
Partially enclosed fuel tank compartments vents were found blocked by signage. Remove signs to allow the vents full air flow.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 June 2025
Resolution: Received photos of signs removed.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 9 June 2025
Resolved
Provide 2025 drug testing enrollment list, including new hire vessel master.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 June 2025
Resolution: Received 2025 enrollment list.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 11 July 2022
Resolved
ALL VESSELS MUST UNDERGO AN ANNUAL INSPECTION WITHIN 3 MONTHS BEFORE OR AFTER EACH ANNIVERSARY DATE. VSL IS OVERDUE FOR IT'S REQUIRED ANNUAL AS OF 05 JULY 2022.
VSL IS RESTRICTED FROM OPERATIONS CARRYING PASSENGERS UNTIL IT'S REQUIRED INSPECTION IS COMPLETED.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 July 2022
Resolution: Conducted annual
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 22 June 2020
Resolved
Install one (1) 10-B:C portable fire extinguisher at operating station in accordance with 46CFR181.500. Due prior to the carriage of passengers.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 June 2020
Resolution: Installed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 June 2020
Resolved
Install three (3) 2.5 gallon fire buckets aboard vessel in accordance with 46CFR181.600. Due prior to the carriage of passengers.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 June 2020
Resolution: Installed.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 22 June 2020
Resolved
Prove proper operation of anchor light in accordance with 46CFR183.420 prior to operating at night.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 20 July 2020
Resolution: Loose ground repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 June 2020
Resolved
Install type-2 retro on ring life buoy in accordance with 46CFR185.604. Due 06Jul2020.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2020
Resolved 3 August 2020
Resolution: Received report from master that retro has been installed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 June 2020
Resolved
Properly mount three (3) fire extinguishers using USCG approved brackets in accordance with 46CFR162.028. Due 06Jul2020.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2020
Resolved 26 June 2020
Resolution: Mounted.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 22 June 2020
Resolved
At next scheduled drydock, crop out defective weld located on starboard pontoon bow, inboard side (approximately 3" weld segment). Due no later than 10Apr2021.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 10 April 2021
Resolved 19 April 2021
Resolution: Vessel rep emailed picture.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 5 June 2019
Resolved
Provide proof of enrollment in drug consortium for 2019.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 June 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 June 2019
Resolved
Provide valid alcohol test strips.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 June 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 June 2019
Resolved
Remove or properly cap off exposed wires on port bow.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 July 2019
Resolved 18 July 2019
Engineering › Fuel Oil Service System › Hose
Issued 10 April 2018
Resolved
Replace degraded fuel lines on port and starboard engines with approved SAE J-1942 hoses, double clamped at all unions.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2018
Resolution: Replaced degraded fuel lines.
Fire Fighting › Portable CO2 Fire Extinguisher › Condition
Issued 10 April 2018
Resolved
Replace degraded fire extinguishers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2018
Resolution: Replaced degraded fire extinguishers.
Construction/Loadline › Hull › Weld
Issued 10 April 2018
Resolved
Repair cracks to transom in way of starboard pontoon mount and center strength beam between both engines.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2018
Resolution: Repaired cracks.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 10 April 2018
Resolved
Replace degraded corrosion resistant clips on ring life buoy.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 May 2018
Resolved 11 May 2018
Resolution: Replaced degraded corrosion resistant clips on ring life buoy.
Lifesaving › Lifebuoys › Serviceable
Issued 10 April 2018
Resolved
Replace degraded grab lines on ring life buoy.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 May 2018
Resolved 11 May 2018
Resolution: Replace ring life buoy.
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 April 2018
Resolved
Properly support wire runs under the main deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 May 2018
Resolved 11 May 2018
Resolution: Properly supported wire runs under the main deck.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 15 May 2017
Resolved
Provide 03 adult size life jackets (vessel is restricted to 19 total persons)
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 15 May 2017
Engineering › Fuel Oil Service System › Tank
Issued 15 May 2017
Resolved
Prove proper operation for stbd fuel tank sensor
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 15 June 2017
Engineering › Gasoline Engine (propulsion) › Engine Block (4 cycle)
Issued 15 May 2017
Resolved
Prove proper operation for portside engine trim tabs
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 15 June 2017
Fire Fighting › Remote Fuel Shutoff › General
Issued 25 March 2016
Resolved
Vessel did not have remote fuel shutoffs for the port and stbd fuel tanks.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 March 2016
Resolved 25 March 2016