MAURY USCG vessel records
← All vessels

A HUI HOU

Built
2006
Last inspected
3 October 2025
Documentation
No record in the NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 3 October 2025
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDJ7851
864339
Flag
UNITED STATES
Maury page id
psix-864339

Documentation record

Tonnage as PSIX records it3 - Simplified, Gross Ton
3 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 15 inspections, each with its date, unit and type; 17 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 15

3 October 2025 Administrative Inspection · COI Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8245706
24 September 2025 Drydock Exam
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8241594
7 January 2025 Annual Inspection · Deficiency Check
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8063186
11 January 2024 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7848346
30 September 2023 Annual Inspection · Drydock Exam · Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7800946
7 December 2022 Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7606181
5 January 2022 In-Service Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7375759
19 October 2021 Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7345087
15 October 2020 COI Inspection · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7077452
29 October 2019 Drydock Exam · In-Service Inspection · Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6842203
1 October 2019 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6826050
22 January 2019 Internal Structural Exam · Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6613452
11 January 2018 Deficiency Check · Annual Inspection · Administrative Inspection · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6306315
17 October 2017 Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6288841
28 November 2016 Hull Examination · Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6043241

Deficiency record · 17

01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 3 October 2025 Resolved
New vessel owner/operator for vessel. Need the following information to complete the COI process/issuance: -Tax ID number -Bill of Sale
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 October 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 October 2025 Resolved
Vessel required to have the required number of life jackets for children weighing 90 lbs or less; 10% of total required life jackets. Vessel operator required to add one (01) more child life jacket.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2025
Resolved 21 October 2025
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 January 2025 Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crewmembers on inspected vessels who: Occupy a position, or perform the duties and functions of a position, required by the vessel's Certificate of Inspection. Need to enroll vessel one (01) crew member in a random testing program IAW 46 CFR Part 16.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 February 2025
Resolved 15 January 2025
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 7 December 2022 Resolved
Except as otherwise allowed by this subpart, a vessel must comply with the structural design requirements of one of the standards listed for the hull material condition. The bilge bottom plating pitting appears beyond acceptable standard. Owner to devise plan to prove pitting is within acceptable limits as per structural design standards in 46 CFR 177.300 or to provide repair proposal. Submit plan to OCMI no later than 07 April 2023. Marine inspector must be present for gauging of material of concern.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 April 2023
Resolved 8 May 2023
Resolution: Vessel submitted proposal to get the bilge bottom plate evauated by certified welder in presence of marine inspector on 8 May 2023.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 December 2022 Resolved
Where flexible nonmetallic hose is permitted for use in piping systems by this section, it must meet SAE J-1942 and Flexible nonmetallic hose must be complete with factory-assembled end fittings requiring no further adjustment of the fittings on the hose, or field attachable type fittings may be used. Hose end fittings must comply with SAE J-1475. Flexible nonmetallic hoses are not SAE J-1942 at the fuel tank connection to fuel filter. This to be completed no later than 07 April 2023.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 April 2023
Resolved 10 April 2023
Resolution: New fuel hoses replaced with J1942.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 January 2022 Resolved
A vsl must have one or more ring buoys. Ring buoy grab line were no longer serviceable.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 5 February 2022
Resolved 5 January 2022
Resolution: Replaced with new ring buoy.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 January 2022 Resolved
Child size life jackets equal to at least 10% of the number of persons permitted. 2 child size life jackets were missing retro reflective tapes.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 5 February 2022
Resolved 5 January 2022
Resolution: Replaced with two child size life jackets.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 5 January 2022 Resolved
Except as otherwise allowed by this subpart, a vessel must comply with the structural design requirements of one of the standards listed below. The vessel could not demonstrate the overpressure test. The vessel needs to conduct the overpressure "stress" test IAW Sector Honolulu Work Instruction 07 in the presence of an attending Coast Guard Marine Inspector and prior to operating with passengers.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 February 2022
Resolved 6 January 2022
Resolution: Conducted satisfactory overpressure stress test.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 January 2022 Resolved
A visual and audible alarm must be provided at the operation station to indicate a high water level. Visual indicator did not work.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 January 2022
Resolved 1 February 2022
Resolution: New alarm installed and tested satisfactorily.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 5 January 2022 Resolved
Pre-engineered fixed gas fire extinguishing systems must automatically shut down all power ventilation system. Did not demonstrate the ventilation shutdown.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 January 2022
Resolved 6 January 2022
Resolution: Satisfactorily witnessed the shutdown of all power ventilation.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 5 January 2022 Resolved
Fuses must be of the cartridge type only and be listed by Underwriters Lab. Fuses were automotive spade type fuses.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 February 2022
Resolved 1 February 2022
Resolution: New cartridge type fuse block installed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 5 January 2022 Resolved
Electrical equipment in spaces containing machinery powered by, or fuel tanks for, gasoline or other fuels having a flashpoint of 43.3 °C (110 °F) or lower must be explosion-proof or ignition-protected, or be part of an intrinsically safe system. a. Gasoline fuel filters and hoses are located in same compartment as unprotected battery selector switch and other electrical connections. b. Gasoline fuel tank space and adjacent helm station with unprotected electrical wirings was not gas tight.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 February 2022
Resolved 1 February 2022
Resolution: Gasoline fuel filters relocated and all electrical penetraions made vapor tight.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 January 2022 Resolved
A mechanical exhaust system consisting of at least two ventilation exhaust ducts located at the end of the space opposite ends. Only one non rigid exhaust duct provided.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 February 2022
Resolved 1 February 2022
Resolution: Two rigid exhaust ducts provided.
Engineering › Gasoline Engine (propulsion) › Gasoline Fuel Tank Ventilation
Issued 11 January 2018 Resolved
Vessel needs to be equipped with an operational vapor detection system. Prior to operation, the vessel is required to run ventilation at twice the allotted run time and vessel master shall log that in the vessel’s official log book.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 January 2018
Resolved 24 January 2018
Resolution: The vessel's vapor detection system is now operational.
Lifesaving › Visual Distress Signals (General) › Expired
Issued 11 January 2018 Resolved
Vessel needs to replace all expired distress signals onboard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 January 2018
Resolved 11 January 2018
Resolution: The vessel's expired distress signals were changed with new ones.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 11 January 2018 Resolved
Vessel needs to properly stencil the vessel’s name and hailing port on a visible area of the hull.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 January 2018
Resolved 24 January 2018
Resolution: The vessel's name and hailing port have been stenciled on a visible area of the hull.
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 28 November 2016 Resolved
Vessel needs to be equipped with an operable vapor detection system for vessels operating using gasoline.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 28 November 2016
Resolved 29 November 2016
Resolution: Vessel owner had the vapor dector replaced. Tested, all sat.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.