Inspection history · 15
3 October 2025
Administrative Inspection · COI Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8245706
24 September 2025
Drydock Exam
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8241594
7 January 2025
Annual Inspection · Deficiency Check
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8063186
11 January 2024
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7848346
30 September 2023
Annual Inspection · Drydock Exam · Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7800946
7 December 2022
Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7606181
5 January 2022
In-Service Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7375759
19 October 2021
Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7345087
15 October 2020
COI Inspection · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7077452
29 October 2019
Drydock Exam · In-Service Inspection · Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6842203
1 October 2019
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6826050
22 January 2019
Internal Structural Exam · Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6613452
11 January 2018
Deficiency Check · Annual Inspection · Administrative Inspection · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6306315
17 October 2017
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6288841
28 November 2016
Hull Examination · Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6043241
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 3 October 2025
Resolved
New vessel owner/operator for vessel. Need the following information to complete the COI process/issuance:
-Tax ID number
-Bill of Sale
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 October 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 October 2025
Resolved
Vessel required to have the required number of life jackets for children weighing 90 lbs or less; 10% of total required life jackets. Vessel operator required to add one (01) more child life jacket.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2025
Resolved 21 October 2025
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 January 2025
Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crewmembers on inspected vessels who: Occupy a position, or perform the duties and functions of a position, required by the vessel's Certificate of Inspection. Need to enroll vessel one (01) crew member in a random testing program IAW 46 CFR Part 16.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 February 2025
Resolved 15 January 2025
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 7 December 2022
Resolved
Except as otherwise allowed by this subpart, a vessel must comply with the structural design requirements of one of the standards listed for the hull material condition. The bilge bottom plating pitting appears beyond acceptable standard. Owner to devise plan to prove pitting is within acceptable limits as per structural design standards in 46 CFR 177.300 or to provide repair proposal. Submit plan to OCMI no later than 07 April 2023. Marine inspector must be present for gauging of material of concern.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 April 2023
Resolved 8 May 2023
Resolution: Vessel submitted proposal to get the bilge bottom plate evauated by certified welder in presence of marine inspector on 8 May 2023.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 December 2022
Resolved
Where flexible nonmetallic hose is permitted for use in piping systems by this section, it must meet SAE J-1942 and Flexible nonmetallic hose must be complete with factory-assembled end fittings requiring no further adjustment of the fittings on the hose, or field attachable type fittings may be used. Hose end fittings must comply with SAE J-1475. Flexible nonmetallic hoses are not SAE J-1942 at the fuel tank connection to fuel filter. This to be completed no later than 07 April 2023.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 April 2023
Resolved 10 April 2023
Resolution: New fuel hoses replaced with J1942.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 January 2022
Resolved
A vsl must have one or more ring buoys. Ring buoy grab line were no longer serviceable.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 5 February 2022
Resolved 5 January 2022
Resolution: Replaced with new ring buoy.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 January 2022
Resolved
Child size life jackets equal to at least 10% of the number of persons permitted. 2 child size life jackets were missing retro reflective tapes.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 5 February 2022
Resolved 5 January 2022
Resolution: Replaced with two child size life jackets.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 5 January 2022
Resolved
Except as otherwise allowed by this subpart, a vessel must comply with the structural design requirements of one of the standards listed below. The vessel could not demonstrate the overpressure test. The vessel needs to conduct the overpressure "stress" test IAW Sector Honolulu Work Instruction 07 in the presence of an attending Coast Guard Marine Inspector and prior to operating with passengers.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 February 2022
Resolved 6 January 2022
Resolution: Conducted satisfactory overpressure stress test.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 January 2022
Resolved
A visual and audible alarm must be provided at the operation station to indicate a high water level. Visual indicator did not work.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 January 2022
Resolved 1 February 2022
Resolution: New alarm installed and tested satisfactorily.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 5 January 2022
Resolved
Pre-engineered fixed gas fire extinguishing systems must
automatically shut down all power ventilation system.
Did not demonstrate the ventilation shutdown.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 January 2022
Resolved 6 January 2022
Resolution: Satisfactorily witnessed the shutdown of all power ventilation.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 5 January 2022
Resolved
Fuses must be of the cartridge type only and be listed by Underwriters Lab. Fuses were automotive spade type fuses.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 February 2022
Resolved 1 February 2022
Resolution: New cartridge type fuse block installed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 5 January 2022
Resolved
Electrical equipment in spaces containing machinery powered by, or fuel tanks for, gasoline or other fuels having a flashpoint of 43.3 °C (110 °F) or lower must be explosion-proof or ignition-protected, or be part of an intrinsically safe system.
a. Gasoline fuel filters and hoses are located in same compartment as unprotected battery selector switch and other electrical connections.
b. Gasoline fuel tank space and adjacent helm station with unprotected electrical wirings was not gas tight.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 February 2022
Resolved 1 February 2022
Resolution: Gasoline fuel filters relocated and all electrical penetraions made vapor tight.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 January 2022
Resolved
A mechanical exhaust system consisting of at least two ventilation exhaust ducts located at the end of the space opposite ends. Only one non rigid exhaust duct provided.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 February 2022
Resolved 1 February 2022
Resolution: Two rigid exhaust ducts provided.
Engineering › Gasoline Engine (propulsion) › Gasoline Fuel Tank Ventilation
Issued 11 January 2018
Resolved
Vessel needs to be equipped with an operational vapor detection system. Prior to operation, the vessel is required to run ventilation at twice the allotted run time and vessel master shall log that in the vessel’s official log book.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 January 2018
Resolved 24 January 2018
Resolution: The vessel's vapor detection system is now operational.
Lifesaving › Visual Distress Signals (General) › Expired
Issued 11 January 2018
Resolved
Vessel needs to replace all expired distress signals onboard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 January 2018
Resolved 11 January 2018
Resolution: The vessel's expired distress signals were changed with new ones.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 11 January 2018
Resolved
Vessel needs to properly stencil the vessel’s name and hailing port on a visible area of the hull.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 January 2018
Resolved 24 January 2018
Resolution: The vessel's name and hailing port have been stenciled on a visible area of the hull.
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 28 November 2016
Resolved
Vessel needs to be equipped with an operable vapor detection system for vessels operating using gasoline.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 28 November 2016
Resolved 29 November 2016
Resolution: Vessel owner had the vapor dector replaced. Tested, all sat.