Records from 2016 to 2026. Most recent: inspection, 6 April 2026.
Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
Documentation record
Registered dimensions (L × B × D)46.0 ft × 15.4 ft × 4.0 ft
Registered tonnagegross 18 / net 15
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCHESAPEAKE BOATS INC · CRISFIELD, MD, UNITED STATES · built 2006
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portREEDVILLE, VA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 7 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it18 - Simplified, Gross Ton
15 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page
20 inspections, each with its date, unit and type; 17 deficiencies with the resolution recorded against each; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
Plans
Sign in
Maury does not score, rate or grade vessels, at any price.
Inspection history · 20
6 April 2026
Drydock Exam · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8343794
11 March 2026
Administrative Inspection · COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8324717
28 May 2025
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8157420
5 June 2024
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7926906
26 March 2024
Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7882539
31 May 2023
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7685788
2 June 2022
Annual Inspection · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7479142
24 March 2022
Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7417455
4 March 2021
COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7146021
9 June 2020
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6968972
18 March 2020
Internal Structural Exam · Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6924838
14 May 2019
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6677927
28 March 2019
In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6651773
29 May 2018
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6435593
8 May 2018
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6407830
28 February 2018
Internal Structural Exam · Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6363144
23 May 2017
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6177490
10 May 2017
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6138731
17 March 2016
Hull Examination · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5832599
10 March 2016
COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5826166
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 11 March 2026
Resolved
To maintain a valid COI, you must complete your annual inspection within the periods specified in 176.500(b)(1). The HERITAGE exceeded the required interval for its COI renewal inspection and is not authorized to operate until a valid COI has been issued.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 19 March 2026
Resolution: conducted satisfactory COI renewal inspection and issued temp COI
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 31 May 2023
Resolved
A vessel on an oceans, coastwise, limited coastwise, or Great Lakes route must carry - six hand red flare distress signals ... and six hand orange smoke distress signals approved in accordance with 160.037. Vessel had four usable hand red flares.
46 CFR 180.68(a)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2023
Resolved 3 June 2023
Resolution: Vessel provided proof of purchase of additional required red hand flares.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 31 May 2023
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date ... U.S. Coast Pilot or similar publication. Vessel had an expired Coast Pilot.
46 CFR 184.420(a)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2023
Resolved 3 June 2023
Resolution: Vessel provided proof of printed current Coast Pilot.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 31 May 2023
Resolved
A vessel not required to have a power driven fire pump ... must have at least three 9.5 liter (2.5 gal) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. Vessel had three 5 gal buckets.
46 CFR 181.610
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2023
Resolved 3 June 2023
Resolution: Vessel provided proof of purchase of 03 labeled, 2.5gal buckets.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 31 May 2023
Resolved
Each life float must be fitted with a lifeline, pendants, two paddles, a painter, and a light. The light for one of the life floats was inoperable.
46 CFR 180.175(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2023
Resolved 3 June 2023
Resolution: Vessel provided proof of purchase of new lifefloat light.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 4 March 2021
Resolved
Vessel had out of date Coast Pilot, CG Light List, and Charts used for intended voyage.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 March 2021
Resolved 14 March 2021
Resolution: Vessel master sent in documentation of updated navigational charts, Light Lists, and Coast Pilot
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 June 2020
Resolved
Sections over 150 degrees fahrenheit require lagging. Portion between the turbocharger and salt water cooling had no lagging.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 June 2020
Resolved 10 August 2020
Resolution: Salt water cooled side of the turbocharger had the appropriately rated lagging installed.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 9 June 2020
Resolved
As appropriate for the intended voyage, a vessel must carry adequete and up-to-date charts. Vessel needs new up-to-date charts.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 June 2020
Resolved 10 August 2020
Resolution: Physical charts for route listed in COI were purchased and present for vessel.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 9 June 2020
Resolved
Vessel required to have a registered EPIRB onboard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 June 2020
Resolved 10 August 2020
Resolution: Appropriate EPIRB registration documents were presented and the EPIRB sticker was added to the EPIRB.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 14 May 2019
Resolved
Visual indicator at operating station did not illuminate during forward compartement bilge test. A visual indication must be provided at operating station when bilge is operating. Vessel operator fixed on the spot.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 14 May 2019
Resolution: Owner fixed on the spot
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 May 2019
Resolved
Found required fire buckets not properly labeled. Vessel owner labeled fire buckets.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 14 May 2019
Resolution: Owner fixed on the spot
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 14 May 2019
Resolved
Found distress signal container not properly labeled. Vessel owner properly labeled distress signal container.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 14 May 2019
Resolution: Owner fixed on the spot
Engineering › Fuel Oil Service System › Piping
Issued 8 May 2018
Resolved
Fuel tubing connections and fittings must be nonferrous drawn or forged metal of the flared type. Vessel has copper tubing terminating in flexible hose with double hose clamp as fitting. Needs to be installed per regulations using proper flare fitting or nonmetallic lines may be used to meet SAE-J-1942 with approved fittings (flex hose).
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2018
Resolved 29 May 2018
Resolution: Vessel fuel lines replaced with Parker 221FR fuel hose. Hose meets SAE J1942.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 8 May 2018
Resolved
Space protected by fixed gas system must have means of closing air supply ducts. Make adjustment to STBD side engine room air intake so it closes.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2018
Resolved 29 May 2018
Resolution: Vessel added latches to ensure air intakes on both port and STBD side remain secured when closed.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 10 May 2017
Resolved
Vessel's Light List and Coast Pilot were outdated. Replace outdated nautical publications with updated versions.
Condition: Invalid
Action required: 705 - Other - as specified
Due 24 May 2017
Resolved 23 May 2017
Resolution: Appropriate Light List and Coast Pilot were acquired for the vessel.
Navigation › Piloting/Steering › Marine Charts
Issued 10 May 2017
Resolved
Charts do not cover all area permitted for operation on vessel's COI. Acquire updated, applicable charts.
Condition: Invalid
Action required: 705 - Other - as specified
Due 24 May 2017
Resolved 23 May 2017
Resolution: The appropriate Navigation Charts were acquired for the vessel.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 10 May 2017
Resolved
Vessel's FCC Safety Readiontelephony Certificate has a call sign listed that is different than the call sign listed on the station license. Have certificates reflect the same call sign.
Condition: Invalid
Action required: 705 - Other - as specified
Due 10 June 2017
Resolved 23 June 2017