HERITAGE is a 2006 passenger vessel (inspected). The Coast Guard has recorded 29 inspections since 2006, most recently in April 2026, along with 30 deficiencies.

Records from 2006 to 2026. Most recent: inspection, 6 April 2026.

Built
2006
Last inspected
6 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDJ4132
864374
Flag
UNITED STATES
367774710
Maury page id
psix-864374

Inspections, by type

Years with a record 17 calendar years (2006–2026)
The 29 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)46.0 ft × 15.4 ft × 4.0 ft
Registered tonnagegross 18 / net 15
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCHESAPEAKE BOATS INC · CRISFIELD, MD, UNITED STATES · built 2006
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portREEDVILLE, VA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 7 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it18 - Simplified, Gross Ton
15 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDJ4132MMSI 367774710 · active · compulsorily equipped · granted 25 February 2017, expires 25 February 2027
WDD5212MMSI 367155180 · expired · compulsorily equipped · granted 13 December 2006, cancelled 18 February 2017
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 29

6 April 2026 Drydock Exam · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8343794
11 March 2026 Administrative Inspection · COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8324717
28 May 2025 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8157420
5 June 2024 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7926906
26 March 2024 Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7882539
31 May 2023 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7685788
2 June 2022 Annual Inspection · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7479142
24 March 2022 Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7417455
4 March 2021 COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7146021
9 June 2020 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6968972
18 March 2020 Internal Structural Exam · Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6924838
14 May 2019 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6677927
28 March 2019 In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6651773
29 May 2018 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6435593
8 May 2018 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6407830
28 February 2018 Internal Structural Exam · Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6363144
23 May 2017 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6177490
10 May 2017 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6138731
17 March 2016 Hull Examination · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5832599
10 March 2016 COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5826166
14 March 2014 Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4814934
9 March 2014 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4809852
28 December 2011 COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4201693
16 February 2011 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3943743
21 January 2010 Annual Inspection · DAPI Audit
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3664621
18 February 2009 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3419625
24 November 2008 Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3366454
29 February 2008 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3168138
20 July 2006 Deficiency Check · Construction Oversight · Simplified Stability Test · Initial Certification · Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2823605

Deficiency record · 30

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 11 March 2026 Resolved
To maintain a valid COI, you must complete your annual inspection within the periods specified in 176.500(b)(1). The HERITAGE exceeded the required interval for its COI renewal inspection and is not authorized to operate until a valid COI has been issued.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 19 March 2026
Resolution: conducted satisfactory COI renewal inspection and issued temp COI
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 31 May 2023 Resolved
A vessel on an oceans, coastwise, limited coastwise, or Great Lakes route must carry - six hand red flare distress signals ... and six hand orange smoke distress signals approved in accordance with 160.037. Vessel had four usable hand red flares. 46 CFR 180.68(a)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2023
Resolved 3 June 2023
Resolution: Vessel provided proof of purchase of additional required red hand flares.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 31 May 2023 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date ... U.S. Coast Pilot or similar publication. Vessel had an expired Coast Pilot. 46 CFR 184.420(a)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2023
Resolved 3 June 2023
Resolution: Vessel provided proof of printed current Coast Pilot.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 31 May 2023 Resolved
A vessel not required to have a power driven fire pump ... must have at least three 9.5 liter (2.5 gal) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. Vessel had three 5 gal buckets. 46 CFR 181.610
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2023
Resolved 3 June 2023
Resolution: Vessel provided proof of purchase of 03 labeled, 2.5gal buckets.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 31 May 2023 Resolved
Each life float must be fitted with a lifeline, pendants, two paddles, a painter, and a light. The light for one of the life floats was inoperable. 46 CFR 180.175(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2023
Resolved 3 June 2023
Resolution: Vessel provided proof of purchase of new lifefloat light.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 4 March 2021 Resolved
Vessel had out of date Coast Pilot, CG Light List, and Charts used for intended voyage.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 March 2021
Resolved 14 March 2021
Resolution: Vessel master sent in documentation of updated navigational charts, Light Lists, and Coast Pilot
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 June 2020 Resolved
Sections over 150 degrees fahrenheit require lagging. Portion between the turbocharger and salt water cooling had no lagging.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 June 2020
Resolved 10 August 2020
Resolution: Salt water cooled side of the turbocharger had the appropriately rated lagging installed.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 9 June 2020 Resolved
As appropriate for the intended voyage, a vessel must carry adequete and up-to-date charts. Vessel needs new up-to-date charts.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 June 2020
Resolved 10 August 2020
Resolution: Physical charts for route listed in COI were purchased and present for vessel.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 9 June 2020 Resolved
Vessel required to have a registered EPIRB onboard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 June 2020
Resolved 10 August 2020
Resolution: Appropriate EPIRB registration documents were presented and the EPIRB sticker was added to the EPIRB.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 14 May 2019 Resolved
Visual indicator at operating station did not illuminate during forward compartement bilge test. A visual indication must be provided at operating station when bilge is operating. Vessel operator fixed on the spot.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 14 May 2019
Resolution: Owner fixed on the spot
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 May 2019 Resolved
Found required fire buckets not properly labeled. Vessel owner labeled fire buckets.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 14 May 2019
Resolution: Owner fixed on the spot
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 14 May 2019 Resolved
Found distress signal container not properly labeled. Vessel owner properly labeled distress signal container.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 14 May 2019
Resolution: Owner fixed on the spot
Engineering › Fuel Oil Service System › Piping
Issued 8 May 2018 Resolved
Fuel tubing connections and fittings must be nonferrous drawn or forged metal of the flared type. Vessel has copper tubing terminating in flexible hose with double hose clamp as fitting. Needs to be installed per regulations using proper flare fitting or nonmetallic lines may be used to meet SAE-J-1942 with approved fittings (flex hose).
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2018
Resolved 29 May 2018
Resolution: Vessel fuel lines replaced with Parker 221FR fuel hose. Hose meets SAE J1942.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 8 May 2018 Resolved
Space protected by fixed gas system must have means of closing air supply ducts. Make adjustment to STBD side engine room air intake so it closes.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2018
Resolved 29 May 2018
Resolution: Vessel added latches to ensure air intakes on both port and STBD side remain secured when closed.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 10 May 2017 Resolved
Vessel's Light List and Coast Pilot were outdated. Replace outdated nautical publications with updated versions.
Condition: Invalid
Action required: 705 - Other - as specified
Due 24 May 2017
Resolved 23 May 2017
Resolution: Appropriate Light List and Coast Pilot were acquired for the vessel.
Navigation › Piloting/Steering › Marine Charts
Issued 10 May 2017 Resolved
Charts do not cover all area permitted for operation on vessel's COI. Acquire updated, applicable charts.
Condition: Invalid
Action required: 705 - Other - as specified
Due 24 May 2017
Resolved 23 May 2017
Resolution: The appropriate Navigation Charts were acquired for the vessel.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 10 May 2017 Resolved
Vessel's FCC Safety Readiontelephony Certificate has a call sign listed that is different than the call sign listed on the station license. Have certificates reflect the same call sign.
Condition: Invalid
Action required: 705 - Other - as specified
Due 10 June 2017
Resolved 23 June 2017
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 10 March 2014 Resolved
Vessel's child size lifejackets did not have lights installed, which are required due to its coastwise route. (46 CFR 180.75)
Action required: 705 - Other - as specified
Due 10 April 2014
Resolved 13 March 2014
Resolution: Owner installed lights on the child size lifejackets.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 28 December 2011 Resolved
Pre-engineered fire fighting system override was not tested during COI. Provide proof of annual servicing requirement IAW 46 CFR 176.810 within 14 days.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 January 2012
Resolved 18 January 2012
Resolution: Vessel rep emailed a copy of the fire fighting servicing certificate from [name withheld] & Safety. The certificate clearly states that the automatic shutdown of the engine and the override were tested and operating properly; all sat.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 16 February 2011 Resolved
Vessel does not have an operable stern light. Prove operable condition of stern light IAW 46 CFR 183.420 to the approval of the marine inspector prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 February 2011
Resolution: Vessel replaced bulb in stern light
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 16 February 2011 Resolved
Vessel does not have alcohol test kits. Provide alcohol test kits IAW 46 CFR 185.210 to the approval of the marine inspector prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 February 2011
Resolution: Provided receipt of purchase for drug test kits
Operations/Management › Pollution › Control of Discharge of Oil
Issued 16 February 2011 Resolved
Vessel does not have oil discharge placard. Provide placard IAW 33 CFR 155.450 to the approval of marine inspector within 14 days.
Due 2 March 2011
Resolved 24 February 2011
Resolution: Posted approved Oil Discharge Placard.
Navigation › Piloting/Steering › Marine Charts
Issued 16 February 2011 Resolved
Vessel does not have up to date charts. Provide charts IAW 46 CFR 184.420 to the approval of the marine inspector prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 February 2011
Resolution: Vessel purchased current charts for AOR
Engineering › Fuel Oil Service System › Valve
Issued 16 February 2011 Resolved
Provide label for fuel shutoff valves IAW 46 CFR 185.608 and demonstrate accessibility of the fuel shutoff valves to the attending Coast Guard Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 February 2011
Resolution: Labeled hatch cover to access fuel shut-off valves in space and demonstrated ability to quickly access the space.
Stability › Watertight Integrity › General
Issued 16 February 2011 Resolved
Make sewage through-hull flexible hose fitting through water tight bulkhead watertight. Provide proposal of how to make watertight. Provide proposal of how to make watertight and prove that through-hull is watertight to the satisfaction of marine inspectors prior to carrying passengers IAW 46 CFR 182.720.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 February 2011
Resolution: The space around the hose through the bulkhead is sealed with caulk
Lifesaving › Lifebuoys › Serviceable
Issued 21 January 2010 Resolved
No Retro on ring buoy. Provide retro on ring buoy IAW 46 CFR 185.604 (i) Prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 February 2010
Resolved 15 April 2010
Resolution: Provided retro reflective tape on ring buoy
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 21 January 2010 Resolved
Replace lifefloat light on port side lifefloat IAW 46 CFR 180.150 Prior to carrying more than 12 persons.
Action required: 705 - Other - as specified
Due 22 February 2010
Resolved 5 April 2010
Resolution: Lifefloat light replaced.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 21 January 2010 Resolved
Replace hydro for EPIRB prior to operation beyond 3 NM. IAW 46 CFR 185.740
Action required: 705 - Other - as specified
Due 22 February 2010
Resolved 5 April 2010
Resolution: New Hydro installed on EPIRB.
Engineering › Lubricating Oil Service System › Valve
Issued 18 February 2009 Resolved
CAP LUBE OIL SYSTEM DRAIN HOSE TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 4 March 2009
Resolved 16 March 2009
Resolution: LUBE OIL SYSTEM DRAIN HOSE CAPPED.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 18 February 2009 Resolved
REPAIR MASTHEADLIGHT IAW 46 CFR 183.420, PRIOR TO OPERATING AT NIGHT
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 16 March 2009
Resolution: MASTHEAD LIGHT REPLACED.