DISPATCHER

DISPATCHER is a 1965 towing vessel. The Coast Guard has recorded 8 inspections since 2015, most recently in April 2025, along with 10 deficiencies.

Records from 2015 to 2025. Most recent: inspection, 7 April 2025.

Built
1965
Last inspected
7 April 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDI5301
Flag
UNITED STATES
Maury page id
psix-86445

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspections, by type

Years with a record 7 calendar years (2015–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Registered dimensions (L × B × D)43.1 ft × 14.1 ft × 5.8 ft
Registered tonnagegross 13 / net 9
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderHILLSTROM SHIPBUILDING CO · COOS BAY, OR, UNITED STATES · built 1965
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portPORTLAND, OR
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 13 January 2026 · expires 31 January 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it13 - Regulatory (Subpart C or D), Gross Ton
9 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 1980 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspection history · 8

7 April 2025 Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8106509
25 July 2024 Annual Inspection · Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7954297
2 May 2023 Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7675617
14 July 2022 Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7511124
26 May 2022 Initial Certification
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7434127
30 April 2021 Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7186591
28 January 2016 DAPI Audit · Industry Initiated Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5805662
7 December 2015 Administration
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5796740

Deficiency record · 10

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 July 2024 Resolved
Pressure vessels over 5 cubic feet in volume and over 15 pounds per square inch maximum allowable working pressure (MAWP) must be equipped with an indicating pressure gauge (in a readily visible location) and with one or more spring-loaded relief valves. The total relieving capacity of such relief valves must prevent pressure from exceeding the MAWP, as established by the manufacturer, by more than 10 percent. The air receiver in the machinery space has an MAWP of 200 PSI and the relief valve is set at 250 PSI. Provide a relief valve that is set at a pressure below 10% of the MAWP.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 July 2024
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 25 July 2024 Resolved
Each towing vessel must be equipped with at least one fire axe that is readily accessible for use from the exterior of the vessel. Vessel is not fit with a fire axe. Install fire axe and provide evidence to the marine inspector.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2024
Resolved 30 July 2024
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 25 July 2024 Resolved
The owner, managing operator, or master of a towing vessel must ensure that the vessel's lifesaving and fire suppression and detection equipment complies with the applicable requirements of parts 141 and 142 of this subchapter and is in good working order. The fire panel is inoperable. Repair and prove operational to the marine inspector.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 August 2024
Resolved 29 August 2024
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 26 May 2022 Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. No bilge alarms are installed. Install bilge alarms for each space. Prove proper operation to the attending Coast Guard Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 June 2022
Resolved 14 July 2022
Resolution: Installed bilge alarms.
08 - Alarms › N/A - No Subsystem › Steering gear alarm
Issued 26 May 2022 Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. Vessel has hydraulic steering system. No hydraulic oil low level alarm is installed. Install alarm and prove proper operation to the attending Coast Guard Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 June 2022
Resolved 14 July 2022
Resolution: Installed Hydraulic low level alarm.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 26 May 2022 Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. . No Engine high water temp alarm is installed. Install alarm and prove proper operation to the attending Coast Guard Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 June 2022
Resolved 14 July 2022
Resolution: Installed engine high water temp alarm, tested setpoint at 200deg F.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 26 May 2022 Resolved
Alarms must be visible and audible at each operating station. The alarm located at the operating station may be a summary alarm; if the alarm at the operating station is a summary alarm, the specific alarm condition must be indicated at the machinery or bilge location. No audible or visual machinery alarm is installed at the operating station. Install visual and audible alarms and prove proper operation to the attending Coast Guard Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 June 2022
Resolved 14 July 2022
Resolution: Installed new alarm panel on bridge.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 26 May 2022 Resolved
A towing vessel that is certificated for rivers, lakes, bays, and sounds, less than 3 nautical miles from shore on the Great Lakes. Must be equipped with either an approved 160-B semi-portable fire-extinguishing system to protect the engine room or a fixed fire-extinguishing system installed to protect the engine room. 46 CFR 136.110 defines a fixed fire system as a Co2 system that meets the requirements of 46 CFR 76.15. The Co2 system is manually actuated. 46 CFR 76.15-20(b) requires fully automatic actuation when the storage tank is located in the protected space. Provide proposal for re-locating the current tank or modifying the system for fully automatic actuation.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 June 2022
Resolved 14 July 2022
Resolution: Operator granted an exception to allow manual activation of the system. Approval letter in vessel documents.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 26 May 2022 Resolved
Means must be provided for stopping each fan in a ventilation system serving machinery spaces and for closing, in case of fire, each doorway, ventilator, and annular space around funnels and other openings into such spaces. Engine room ventilation on sides of stack does not have covers. Provide covers for engine room vents.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 June 2022
Resolved 14 July 2022
Resolution: operator fabricated and installed vent damper covers. Fans shutdown when Co2 system discharges.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 May 2022 Resolved
There must be an installed or portable bilge pump for emergency dewatering. Any portable pump must have sufficient hose length and pumping capability. All installed bilge piping must have a check/foot valve in each bilge suction that prevents unintended back flooding through bilge piping. Portable bilge pump hose is not long enough to reach all bilge spaces from the main deck. provide longer hose.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 June 2022
Resolved 14 July 2022
Resolution: New longer bilge pump hose onboard. new hose varified long enough to reach all bilges.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.