MAURY USCG vessel records Sign in
← All vessels

MSC ANSHIKA VI

MSC ANSHIKA VI is a 2003 freight ship. The Coast Guard has recorded 31 inspections since 2007, most recently in March 2026, along with 16 deficiencies and 4 operational controls.

Records from 2007 to 2026. Most recent: inspection, 18 March 2026.

Built
2003
Last inspected
18 March 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9254848 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
864651
Flag
PORTUGAL
—
Maury page id
psix-864651

Inspections, by type

…with no type recorded9
Years with a record 12 calendar years (2007–2026)
The 31 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it68047 - Dead Weight, Ton
91414 - Displacement, Ton
64845 - Convention (Subpart B), Gross Ton
36407 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 31

18 March 2026 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8328099
17 March 2026 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8327377
2 February 2026 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8305121
30 January 2026 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8304212
18 October 2025 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8251264
13 October 2025 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8251254
11 October 2025 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8250728
11 October 2025 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8250733
11 October 2025 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8258271
8 October 2025 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8249293
9 January 2025 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8060455
25 May 2024 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7918788
21 September 2023 PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7795065
19 September 2023 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7794316
23 September 2022 PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7564174
10 January 2019 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6605956
30 April 2018 ISPS III Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6402423
20 December 2017 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6323197
16 November 2016 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6042704
14 February 2009 Random ISPS/MTSA/PSC
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3417780
15 July 2008 Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3268405
7 May 2008 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3200673
28 February 2008 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3155269
14 December 2007 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3115339
9 October 2007 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3076491
26 June 2007 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2974611
22 May 2007 Type not recorded
No type recorded · Maritime Safety & Security Team San Francisco (91105) · Activity 2937761
17 May 2007 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2936819
12 March 2007 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2885635
3 February 2007 Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2866482
2 February 2007 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2866261

Deficiency record · 16

04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 19 September 2023 Resolved
EACH EMERGENCY GENERATING SET ARRANGED TO BE AUTOMATICALLY STARTED SHALL BE EQUIPPED WITH... A SECOND SOURCE OF ENERGY SHALL BE PROVIDED FOR AN ADDITIONAL THREE STARTS WITHIN 30 MIN UNLESS MANUAL STARTING CAN BE DEMONSTRATED TO BE EFFECTIVE. SECONDARY MEANS OF STARTING WAS INOPERABLE. HYDRAULIC STARTER FOUND BROKEN.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 September 2023
Resolution: Received class report regarding testing of a portable hydraulic jack station for EGEN and issuance of a Short-Term Safety Construction Certificate.
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 19 September 2023 Resolved
THE INTERNATIONAL LOAD LINE CERTIFICATE (1966) SHALL NOT BE DELIVERED TO THE SHIP UNTIL THE OFFICER OR SURVEYOR... HAS CERTIFIED THAT THE MARKS ARE CORRECTLY AND PERMANENTLY INDICATED ON THE SHIP'S SIDES. VESSEL'S ILLC DOES NOT MATCH THE PERMANENT MARKINGS ON THE SIDE OF THE SHIP. PROVIDE CLARIFICATION FROM CERTIFICATE ISSUING AUTHORITY.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 19 September 2023
Resolved 19 September 2023
Resolution: ISSUING AUTHORITY CLARIFIED THE LOAD LINE CERTIFICATE. LOAD LINE CERTIFICATE IS ACCEPTABLE.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage of rescue boats
Issued 19 September 2023 Resolved
RESCUE BOATS SHALL BE STOWED IN A STATE OF CONTINUOUS READINESS FOR LAUNCHING IN NOT MORE THAN 5 MIN. UPON INSPECTION, RESCUE BOAT WAS NOT IN IMMEDIATE READY STATUS FOR LAUNHC. THE AFT SECURING CABLE LOCK WAS SEIZED/TOO TIGHT TO BE DISCONNECTED. CREW WAS ABLE TO LOOSEN LOCK.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 19 September 2023
Resolved 19 September 2023
Resolution: CREW WAS ABLE TO LOOSEN LOCK.
Engineering › Diesel Engine (auxiliary) › Valve
Issued 20 December 2017 Resolved
1430-Auxiliary engines- In a ship in which fuel is used, the arrangments for the storage, distribution and utilization of the oil fuel shall be such as to ensure the safety of the ship and persons on board. Ship's #1 auxiliary generator HFO fuel oil regulating valve was leaking fuel oil 120 drops per minute. 74SOLAS (04) II-2/4.2.2
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 10 January 2018
Resolution: Received a classification society report from [name withheld] attesting the to the repair of the #1 Auxillary Generator Heavy Fuel Oil regulating valve.
Navigation › Collision/Grounding Avoidance › Radar
Issued 7 May 2008 Resolved
Received notification that the vessel has an inoperable S-Band Radar. The vessel is required to have two independently working radars prior to it's departure. An LOD has been issued for entry.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 May 2008
Resolution: Received a tech report stating that the display was malfunctioning. The display was reset and began to work fine. LOD was lifted.
Lifesaving › Inflatable Liferafts › Not on Board
Issued 3 February 2007 Resolved
Renew 6 person liferaft where lost overboard from port side focsle (vsl has another 6 person rasft stowed on the stbd side).
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 13 March 2007
Resolution: Received class report on 13 Mar 2007 via fax.
Construction/Loadline › Structures › Superstructure
Issued 3 February 2007 Resolved
Repair engine room gantry crane where damaged by falling during heavy weather. Include repairs to peripheral damage such as light fixtures, railings , and deck plates where bent.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 13 March 2007
Resolution: Received class report on 13 Mar 2007 via fax.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 3 February 2007 Resolved
Provide class approval of electric cable at breaker panel LGSP-4 where attached to a spare breaker and placed through an unstuffed hole in the panel face.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 February 2007
Resolved 13 March 2007
Resolution: Received class report on 13 Mar 2007 via fax.
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 February 2007 Resolved
Repair electric wire cable pulled out from main engine axial vibration monitor.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 13 March 2007
Resolution: Received class report on 13 Mar 2007 via fax.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 3 February 2007 Resolved
Doors , both forward and aft found tied open at purifier room rendering the fixed fire extinguishing system ineffective.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 February 2007
Resolved 13 March 2007
Resolution: Received class report on 13 Mar 2007 via fax.
Engineering › Lubricating Oil Service System › Pump
Issued 3 February 2007 Resolved
Repair main engine where cylinder oil system damaged during heavy weather.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 February 2007
Resolved 13 March 2007
Resolution: Received class report on 13 Mar 2007 via fax.
Engineering › Diesel Engine (propulsion-direct drive) › Governor
Issued 3 February 2007 Resolved
Investigate and repair throttle linkage to fuel rack at main engine control station where rubber bicycle inner tubes have been used by the crew as a vibration damper.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 February 2007
Resolved 13 March 2007
Resolution: Received class report on 13 Mar 2007 via fax.
Engineering › Diesel Engine (propulsion-direct drive) › Air Cleaner
Issued 3 February 2007 Resolved
Crew installed brackets located on stbd bulk head outboard and aft of main engine airbox have bent. remove or provide class approval.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 February 2007
Resolved 13 March 2007
Resolution: Received class report on 13 Mar 2007 via fax.
Fire Fighting › Remote Fuel Shutoff › General
Issued 3 February 2007 Resolved
Repair pipe from emergency cutout box to "Vlv of G/E F. O."
Action required: 17 - Rectify deficiencies prior to departure
Due 3 February 2007
Resolved 13 March 2007
Resolution: Received class report on 13 Mar 2007 via fax.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 3 February 2007 Resolved
Repair pipe to the marine sanitation device where crushed and renew #2 vacuum pump.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 February 2007
Resolved 13 March 2007
Resolution: Received class report on 13 Mar 2007 via fax.
Navigation › Collision/Grounding Avoidance › Radar
Issued 2 February 2007 Resolved
Inoperable X-Band Radar. LOD issued in accordance with 33 CFR 164.55. Repair to satisfaction of U.S. Coast Guard
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 February 2007
Resolution: Received tech report that states radar is now operable.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.